nVision Reference Recorder  kg/cm2   Pressure Module (PM) kg/cm2A (Pressure with BARO module) 3 kg/cm2 module 0 to 30% of Range: ±(0.0075% of Full Scale) 30 to 110% of Range: ±(0.025% of Reading) Vacuum: ±(0.06% of Full Scale*, typical) 0 to 30% of Range: ±(0.015% of Full Scale) 30 to 110% of Range: ±(0.05% of Reading) 0 to 30% of Range: ±(0.03% of Full Scale) 30 to 110% of Range: ±(0.1% of Reading) Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. All models indicate vacuum, but vacuum specification (typical) applies to 3, 10, and 30 kg/cm2 models only. Not recommended for continuous use at high vacuum. Refer to XP2i-DP data sheet for gauges that are intended for continuous high vacuum use. 2 * Full Scale = -1.0 kg/cm 301.00 to 1001.00 kg/cm2A: ±(0.1% of Reading) 4794. G nVision kg/cm2 Data Sheet Page 1 of 10

Open the catalog to page 1
nVision Reference Recorder KG Datasheet - 2

nVision Reference Recorder  kg/cm2   DIFFERENTIAL The Tare function canPRESSURE MEASUREMENT UNCERTAINTIES WITH TAREscale pressure range improve measurement uncertainties on two modules with the same full installed into one nVision Reference Recorder. Requires the use of an equalizing valve. The following specifications apply to the measurement system with a logging interval of 1 second/reading: Full Scale Range of Both Sensors Unit must be enabled in CrystalControl DIFFERENTIAL PRESSURE MEASUREMENT UNCERTAINTIES The total nVision Reference Calibrator measurement uncertainty in the ΔP...

Open the catalog to page 2
nVision Reference Recorder KG Datasheet - 3

nVision Reference Recorder  kg/cm2   SENSOR Wetted Materials: ( wrench tight) 316 stainless steel (finger tight) 316 stainless steel and Viton® (internal o-ring) All welded, with a permanently filled diaphragm seal. Metal to metal cone seal; O-ring can be removed if necessary. Diaphragm Seal Fluid: Silicone Oil 1/4" medium pressure tube system compatible with HIP LM4 and LF4 Series, Autoclave Engr SF250CX Male and Female Series. Connection: Crystal CPF Female BAROMETRIC REFERENCE (BARO) Accuracy: ± 0.5 mbar, ± 0.00725 psi Range: 700.0 to 1100.0 mbarA, 10.153 to 15.954 psiA Units and...

Open the catalog to page 3
nVision Reference Recorder KG Datasheet - 4

nVision Reference Recorder  kg/cm2   Current, Voltage, & Switch Test Module (MA20) Intended for use with a 4-20mA loop measurement. This module is also capable of measuring supply voltages and has an auxiliary fixed output for use in switch open/closure testing. Each MA20 module includes a super flexible silicone test lead kit (P/N 3952). CURRENT & VOLTAGE MEASUREMENT Current (mA) Input Accuracy: ±(0.015% of rdg + 0.002 mA) Range: 0 to 55 mA (MA20+) 0 to 25 mA (MA20) Max Allowable Current: 93.3 mA Resolution: 0.001 mA or 0.01% Units: mA, % 4-20, % 10-50 Includes all effects of linearity,...

Open the catalog to page 4
nVision Reference Recorder KG Datasheet - 5

nVision Reference Recorder  kg/cm2   Temperature Module (RTD100) Calibrated for Pt100 RTD / PRT (100 Ohms at 0°C Platinum Resistance Temperature Detector) sensors conforming to DIN/ IEC 60751 (or IEC751) with US, Euro, or Lab calibration curves. An RTD is not included, but each RTD100 includes P/N 3953 RTD Connection Kit. TEMPERATURE MEASUREMENT Resistance Input Accuracy: ± (0.015% of rdg + 0.02 Ω) Range: 0 – 400 Ohms range for use with 100 Ohm PRTs Includes all effects of linearity, hysteresis, repeatability, temperature, and stability for one year. M8 connector cable or terminal block....

Open the catalog to page 5
nVision Reference Recorder KG Datasheet - 6

nVision Reference Recorder  kg/cm2   60 (2.41) nVision Chassis (NV) OPERATING TemperatureTEMPERATURE (-4 to 122° F) Range: -20 to 50° C < 95% RH, non-condensing. No change in accuracy over operating temperature range. Gauge must be zeroed to achieve rated specification. Screen: 255 x 160 pixel graphical display MINI USB-B ACCESS FLAP Applies to all modules. 204.0 (8.05) MAXIMUM WITH TWO PRESSURE MODULES LCD readable in sunlight with bright backlight. Display Rate: 4 readings/second (standard) up to 10 readings/second (recording) The nVision is Intrinsically Safe only if powered by one of...

Open the catalog to page 6
nVision Reference Recorder KG Datasheet - 7

nVision Reference Recorder  kg/cm2   DATA/COMMUNICATION Digital Interface: mini-USB DATALOGGING Capacity: Approx. 1,000,000 data points* Storage Type: Non-volatile flash memory Fastest Interval: 10 per second Slowest Interval: 1 per hour Rating: IP67 Housing: Impact resistant injection molded Keypad and Labels: UV Resistant Polyester Mounting: M4 x 0.7 [8 mm (0.31")] deep threaded insert mounting locations The mini USB will power the nVision with or without the battery pack installed. For hazardous location product warnings, refer to the operation manual. *Single Module Recording Limit of...

Open the catalog to page 7
nVision Reference Recorder KG Datasheet - 8

nVision Reference Recorder  kg/cm2   STORAGE TEMPERATURE Temperature Range: -40 to 75° C (-40 to 167° F) Batteries should be removed if stored for more than one month. SPECIAL FEATURES following requires the use of our free CrystalControl software The Data Point Counter: Screen for counting the data points logged. Display Screens: Turn on and rearrange display screens. Live PC Graph: During a recording, graph directly to your PC. Password Protect: Changes to configuration or userspan calibration factor(s). Pressure Switch Test: Using a PM and MA20, get deadband and state-change pressure....

Open the catalog to page 8
nVision Reference Recorder KG Datasheet - 9

nVision Reference Recorder  kg/cm2   RANGE & RESOLUTION TABLE Display Resolution PM (Add one digit of resolution for differential mode.) ORDERING INFORMATION * Upper Module Lower Module BARO Module Pump System** Carrying Case~ Full . . . . . . . (omit) Aluminum . . . . (omit) Blank Plate: Pressure: Current, Voltage, and Switch: If ordering an nVision with only one module installed, enter BNKPLT in the empty module slot. System B (pneumatic) -0.91 to 2 kg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -BXX System B (pneumatic) -0.91 to 40 kg. . . . . . . . . . . . . . . . . ....

Open the catalog to page 9
nVision Reference Recorder KG Datasheet - 10

nVision Reference Recorder  kg/cm2   PUMP SYSTEMS ACCESSORIES (Included with NV) All pump systems for the nVision include 1/4 NPT and BSP female fittings and a carrying case with Soft Carrying Case P/N 4087 custom insert. Additional fittings and accessories included with individual systems are listed below. Durable, padded case with separate pockets for your nVision and accessories. MPH-1 hose, bonded seals, o-ring kit, and teflon tape. Protective Boot P/N 3985 Shock resistant protection, low durometer, Skydrol resistant. MPH-1 hose, bonded seals, o-ring kit, and teflon tape. Mini-USB Cable...

Open the catalog to page 10

All Crystal Engineering catalogs and technical brochures

  1. PTC series

    14 Pages

  2. RTC series

    15 Pages

  3. PK II

    3 Pages

  4. ATMi

    7 Pages

  5. HPC50

    6 Pages

  6. CrystalCalHP

    7 Pages

  7. m1M Manual

    4 Pages

  8. 30 Series

    4 Pages

  9. FastCalXP

    9 Pages