1. Catalogs
  2. CRYSOUND
  3. CRY580 A²B Interface

CRY580 A²B Interface

CRY580 A²B Interface

CRY580 A²B Interface

Product catalog summary
Introduction
The CRY580 A²B Interface is essential in automotive audio systems, converting A²B-transmitted digital audio and control signals into usable formats for amplifiers, speakers, and other devices. It supports bidirectional PCM data, clock, and sync signals over a single differential pair, facilitating multi-channel I²S/TDM communication over distances up to 15 meters.
Main Application Scenarios
Primarily used in automotive microphone testing, the interface captures audio data from microphones over the bus, ensuring data alignment through clock synchronization. This enables testing of microphone sensitivity, frequency response, and other performance metrics.
Highlights
  • High Bandwidth: 50Mbps digital bus supports large audio data transmission.
  • Low Latency: Maintains latency below 50µs by minimizing bus collisions.
  • Flexible Topology: Single-master multi-slave linear topology with daisy-chain support for easy expansion.
  • Flexible Interfaces: Supports multi-channel I²S/TDM audio interfaces for A²B network connectivity.
  • Clock Synchronization: Ensures synchronous sampling and data transmission.
  • Multi-Microphone Input: Supports up to 4 PDM mic inputs per node with simultaneous I²S data reception.
Technical Specifications
  • Topology: Single-master multiple-slave linear topology
  • Audio Interfaces: 3.5mm analog and S/PDIF digital outputs
  • A²B Interface: Supports 4 high-dynamic-range microphone inputs
  • USBi Interface: For hardware programming
  • Bandwidth: 50 Mbps
  • Transmission Distance: 15 meters
  • Rated Voltage/Current: 12 V (DC), 1.5 A
  • Operating Temperature: -10 to 40°C
System Composition
During testing, SonoLab software controls the CRY6151B Electroacoustic Analyzer to generate audio signals, which are converted to sound via a test source. A reference microphone ensures measurement accuracy, while the DUT Mic on the A²B bus captures sound, communicates with the A²B Interface, and outputs analog audio for analysis.
Instruments
Includes the CRY6151B Electroacoustic Analyzer, microphones, sensors, test sound source, A²B Interface, and connecting cables. The analyzer measures parameters like sensitivity, distortion, and impedance with 8-in/4-out channels and 192kHz sampling.
Software
Offers data post-processing with algorithms for abnormal sound analysis, including frequency, loudness, and FFT analysis.
Testing Environment
Utilizes Shielding Boxes, Soundproof Boxes, and Anechoic Chambers for testing.
See more

Catalog excerpts

CRY580 A²B Interface-1

CRY580 A2B InterfaceIntroduction Highlights The CRY580 A2B Interface plays a critical role in automotive audio systems. It converts A2B-transmitted digital audio and control signals into formats that amplifiers, speakers, and other devices can use for playback and processing. It transmits bidirectional PCM data, clock signals, and sync signals over a single differential pair, supporting multichannel l2S/TDM. It ensures stable communication over node distances of up to 15 meters (49 feet), with 1-to-1 or 1-to-many connections enabling shared time-division channels. Through multi-channel connections with automotive microphones, it captures audio data transmitted over the bus while using clock synchronization to ensure data alignment, enabling testing of microphone sensitivity, frequency response, and other performance indicators. • High Bandwidth Featuring a 50Mbps high-bandwidth digital bus, it meets system needs for transmitting large audio data. Minimizes latency caused by bus collisions or packet reconfiguration, typically keeping it below 50ps. • Flexible Topology Adopts single-master multi-slave linear topology with daisy-chain support, requiring no extra processor overhead for easy system expansion and layout. • Flexible Interfaces Supports multi-channel l2S/TDM audio interfaces for bidirectional A2B network connectivity (input/output). • Clock Synchronization Ensures synchronous sampling and data transmission across all system nodes in each frame. • Multi-Microphone Input Supports PDM interfaces, with up to 4 PDM mic inputs per node and simultaneous l2S data reception from multiple mics.

 Open the catalog to page 1
CRY580 A²B Interface-2

["] CRYSOUNDTechnical Specifications Topology Single-master multiple-slave linear 3.5mm Audio Interface Supports analog audio output S/PDIF Interface Supports digital audio output A2B MAIN/SLAVE Supports 4 high-dynamic-range Interface microphone inputs USBi Interface Hardware Programming Transmission Distance 15 meters During testing, SonoLab software controls the CRY6151B Electroacoustic Analyzer to generate specific audio signals. These signals are converted into sound via a test source, while a reference microphone set ensures measurement accuracy. The DUT Mic on the A2B bus captures the sound,...

 Open the catalog to page 2

All CRYSOUND catalogs and technical brochures

  1. CRY721

    2  Pages

  2. CRY720

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.