CRY318 Artificial Ear

CRY318 Artificial Ear

CRY318 Artificial Ear

Product catalog summary
Overview: The CRY318 Artificial Ear by CRYSound Co., Ltd is a measurement device designed to simulate the human ear for acoustic measurements on telephone handsets and earphones. It includes a 1/2 inch Pressure Measurement Microphone, a 1/2 inch Preamplifier, and an Artificial Ear Pedestal.
Features:
  • Complies with IEC 60318-1:2009 Ed. 2.0 standard for electroacoustics, simulating the human ear and head for ear pressing and covering headphones.
  • Adheres to GB/T 25498.1-2010 for calibrating ear simulators used with ear pressing headphones.
  • Follows ITU-T P.57,1 artificial ear recommendations.
Technical Specifications:
  • Compliance: ITU-T P.57 sec.5.1 Type 1 suggestions with IEC60318-1.
  • Frequency Range: 100Hz to 4kHz ±1 dB (artificial ear impedance).
  • Coupled Cavity Frequency Range: 20Hz to 16kHz.
  • Dimensions: Height - 32mm (including connection adapter), Diameter - 60mm.
  • Weight: 208g (including connection adapter).
Applications:
  • Case 1: Uses CRY502 preamplifier (traditional, dB9 connector) or CRY506 (ICP, BNC socket) with a 1/2 inch Pressured field microphone.
  • Case 2: Uses CRY508 preamplifier (ICP, BNC socket) with a 1/2 inch Pressured field microphone.
  • Case 3: Uses CRY509 preamplifier (traditional, air plug) with a 1/2 inch Pressured field microphone.
All cases require an air plug cable to connect with electro-acoustic measuring instruments, which is standardly provided.
See more

Catalog excerpts

CRY318 Artificial Ear-1

CRY 318 Artificial Ear CRY318 Artificial Ear is a measurement device that closely resembles human ear and loads a sound source in the same way with human ear. It mainly used for acoustic measurements on telephone handsets and earphones. The whole unit includes a 1/2 inch Pressure Measurement Microphone, a 1/2 inch Preamplifier and an Artificial Ear Pedestal. IEC 60318-1:2009 Ed. 2.0 Standard electroacoustics - the simulator of the human ear and head, part 1: measuring the ear simulator used for ear pressing and ear covering headphones; GB/T 25498.1-2010 Electroacoustics Head simulator and ear simulator Part 1: calibrate ear simulator used for ear pressing eadphones; ITU-TITU-T suggested P.57,1 artificial ear Technique Specification Comply Standard Frequency Range Coupled cavity frequency range 20Hz ~ 16kHz (coupled cavity using) 32mm (including connection adapter) ITU-T P.57 sec.5.1 Type 1 suggestions with IEC60318-1 208g (including connection adapter) Add: No.31-1, Xianxing Road, Xianlin Industrial Park, Yuhang District, Hangzhou, Zhejiang

 Open the catalog to page 1
CRY318 Artificial Ear-2

 Case 1: Preamplifier: CRY502(tradition , dB9 connector) Or CRY506(ICP, BNC socket) Microphone: 1/2 inch Pressured field Microphone: 1/2inch Pressured field Case 3: Preamplifier: CRY509(tradition , air plug) Microphone: 1/2inch Pressured field Use an air plug cable to connect with the electro-acoustic measuring instruments. The cable is standard provided. Add: No.31-1, Xianxing Road, Xianlin Industrial Park, Yuhang District, Hangzhou, Zhejiang

 Open the catalog to page 2