Catalog excerpts

CRY886-S01 High-Frequency Coupler Kit Components & Description: CRY886 0.4cc High-Frequency Coupler CRY342 1/4” Pre-polarized Pressure Field Measurement Microphone CRY547 1/4” ICP Preamplifier BL5706SMB to BNC Cable / 1.5m Introduction CRY886-S01 is a high-frequency Coupler kit which consisting of the above accessories for test hearing aids at frequencies up to 16kHz. The coupler increases the resonance frequency to 30kHz, so that it will not interfere with measurements in the audible frequency range. The coupler volume is 0.4cc, CRY886-S01 has a sensitivity of 1.5mV/Pa and the noise floor 40dB(A). CRY342 measurement microphone is a pre-polarized 1/4 inch pressure field condenser microphone. It mainly used for high-level and high-frequency measurements since the sensitivity is low. It can measure high sound pressure levels to 168dB. The Titanium membrane can achieve high stability and accuracy in harsh environment. CRY547 preamplifier can combine with 1/4 inch measurement microphone to transform the impedance and amplifier the acoustic signal. This preamplifier has the characteristic of high input impedance, low output impedance, lower noise, wide frequency response range, etc. It can be used for the condition of electroacoustic test system or multi-noise analysis. And finally, CRY886-S01 Coupler kit is designed for accurate and repeatable use, and also suitable for research, measurement and production test applications. Meet IEC TS 62886:2016 Electroacoustic – Hearing aids – Method for measuring electroacoustic performance up to 16kHz Meet IEC 61094-4:1995 Measurement microphones―Part 4: Specifications for working standard microphones Add: No.31-1, Xianxing Road, Xianlin Industrial Park, Yuhang District, Hangzhou, Zhejiang
Open the catalog to page 1
Meet GBT 20441.4-2006 Measurement microphones―Part 4: Specifications for working standard microphones Coupler Volume Resonance Frequency Frequency Response Sensitivity mV/Pa (dBV/Pa) Dynamic range limit (ref.20uPa) Preamplifier Supply Preamplifier Connection Working Temperature Temperature Coefficient Relative Humidity Range CRY886-S01 high-frequency coupler kit typical response curve Add: No.31-1, Xianxing Road, Xianlin Industrial Park, Yuhang District, Hangzhou, Zhejiang
Open the catalog to page 2All CRY SOUND catalogs and technical brochures
-
CRY2624 ATEX Acoustic Imager
2 Pages
-
CRY721
2 Pages
-
CRY720
2 Pages
-
CRY609 Mouth simulator
2 Pages
-
CRY605 Mouth simulator
2 Pages
-
CRY602 Mouth simulator
2 Pages
-
CRY2110 Noise Sensor Use Manual
11 Pages
-
CRY547 Preamplifier
1 Pages
-
CRY512 Preamplifier
1 Pages
-
CRY510 Preamplifier
1 Pages
-
CRY509 preamplifier
1 Pages
-
CRY508 preamplifier
2 Pages
-
CRY507 preamplifier
1 Pages
-
CRY506 preamplifier
1 Pages
-
CRY502 preamplifier
1 Pages
-
CRY501 preamplifier
1 Pages
-
CRY319–S01 2cc Coupler Kit
3 Pages
-
CRY711 Artificial Ear
3 Pages
-
CRY318 Artificial Ear
2 Pages
-
CRY343-C1 Microphone Set
2 Pages
-
CRY2623 brochure
2 Pages
-
CRY5616 Polarity Tester
4 Pages
-
CRY2851 Sound Level Meter
3 Pages
-
CRY574Pro Bluetooth Dongle
1 Pages
-
CRY605 Artificial Mouth
2 Pages