Overview: The XGard ASU is designed to enable Xgard gas detectors to monitor toxic or flammable gases in ventilation ducts without exposing the detectors to high air velocities that could affect sensor performance.
Features:
  • Performance is fully specified between 5m/s and 20m/s ducted airflow.
  • Sampling probes are suitable for ducts from 300mm wide.
  • Strong, lightweight, and compact design.
  • Supplied with all necessary fittings for one Xgard detector.
  • Installation aid for accurate and easy fitting.
  • Color-coded inlet and exhaust probes.
  • Minimal impact on ventilation system functioning.
  • Sensor calibration or replacement can be done without opening the duct.
Operation: The ASU operates by drawing air from the duct through a black perforated inlet probe into its sampling chamber, then exhausting it back into the duct through a white probe. The design ensures air passes through the sampling chamber at approximately 25% of the duct's air speed.
Design: The ASU consists of a grey polycarbonate box with a transparent cover, which can be removed for installation or maintenance. A drilling template is provided to assist in the correct placement of probe entry holes.
Contact Information:
  • UK Office: Crowcon Detection Instruments Ltd, Abingdon, Oxfordshire, UK. Tel: +44 (0) 1235 557700
  • USA Office: Crowcon Detection Instruments Ltd, Earlanger, Kentucky, USA. Tel: +1 859 957 1039
  • Rotterdam Office: Crowcon Detection Instruments Ltd, Rotterdam, Netherlands. Tel: +31 10 421 1232
  • Singapore Office: Crowcon Detection Instruments Ltd, Singapore. Tel: +65 6745 2936
Note: The Xgard gas detector is supplied separately. Crowcon reserves the right to change the design or specification without notice.
See more

Catalog excerpts

ASU (Air Sampling Unit)-1

XGard ASU The ASU enables Xgard gas detectors to monitor toxic or fl ammable gases within ventilation ducts without subjecting the detectors to high air velocities which could affect the sensor. Features Fully specifi ed performance between 5m/s and 20m/s ducted air fl ow Sampling probes suitable for ducts from 300mm wide Strong, lightweight and compact design Supplied with all fi ttings necessary for one Xgard detector • • • • Installation aid for accurate and easy fi tting Colour coded inlet and exhaust probes Minimum effect on ventilation system functioning. Sensor can be calibrated/replaced without opening the duct. • • • •

 Open the catalog to page 1
ASU (Air Sampling Unit)-2

The Crowcon air sampling unit works by taking a sample of air from the duct through a black perforated inlet probe into its sampling chamber. The air is exhausted back into the duct through a white probe. The design of the probes and sampling chamber is arranged so that air passes through the sampling chamber at approximately 25% of the air speed in the duct. The ASU consists of a grey polycarbonate box fi tted with a transparent polycarbonate cover. The transparent window which has a built-in sealing gasket can be removed by undoing four screws to provide access during installation or maintenance....

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.