video corpo cad

Universal Digital Timer DIN Rail Mount 17.5 mm
8Pages

{{requestButtons}}

Catalog excerpts

Universal Digital Timer DIN Rail Mount 17.5 mm - 1

> Digital timer (LED Screen) > Multifunction (23 base functions + options = 138 functions) > Precise time configuration > Optional features: password setting and time limit setting > 2 use modes (basic and advanced) > Programmable without power supply > Wide time range (from 0.1 seconds up to 100 days) > Universal power supply (12-240 Va/c) > Universal connection Output Type R: Relay Output Quantity 1: 1 Output You have a project? Contact us on www.crouzet.com Description: Syr-line, the specialized range at Crouzet, aimed to satisfy the most unique requirements of your applications by innovating in design, engineering and development. The Universal Digital Timer, the new Syr-line timer that fits all your needs. The Universal Digital Timer offers the same ease of use as analog timers but it is powered with visualization, higher-precision and all the functions you need (up to 138). For more information about Crouzet's Syr-line range, please visit www.crouzet.com.

Open the catalog to page 1
Universal Digital Timer DIN Rail Mount 17.5 mm - 2

| | Universal Digital Timer DZ1R08MV1 Input Specifications Rated supply voltage Un Voltage supply tolerance AC supply voltage frequency Galvanic isolation of supply / inputs Immunity to power micro cuts Timing Specifications Specified time ranges Minimum control pulse duration IEC 61812-1 Recovery time (after by de-energisation) IEC 61812-1 ≤ 0.5 % ±150 ms Note: For COMMAND function of SUM and PAUSE, Repeatability is < 0.5 % ± 250ms ≤ 0.5 % ±150 ms Note: For COMMAND function of SUM and PAUSE, Setting Accuracy is < 0.5 % ± 250ms Temperature drift Voltage drift Output Specifications Contact...

Open the catalog to page 2
Universal Digital Timer DIN Rail Mount 17.5 mm - 3

| Universal Digital Timer

Open the catalog to page 3
Universal Digital Timer DIN Rail Mount 17.5 mm - 4

| | Universal Digital Timer DZ1R08MV1 AC/DC main port emissions IEC 61000-6-3 0.15 MHz – 0.5 MHz, 66 dB(μV) – 56 dB(μV) quasi-peak, 56 dB(μV) – 46 dB(μV) average 0.5 MHz – 5 MHz, 56 dB(μV) quasi-peak, 46 dB(μV) average 5 MHz – 30 MHz, 60 dB(μV) quasi-peak, 50 dB(μV) average CISPR 14-1 0.15 MHz – 30 MHz CISPR 16-2-1 (7.4.1), CISPR 16-1-2 (4.3) 0.15 MHz – 0.5 MHz, 79 dB(μV) quasi-peak, 66 dB(μV) average 0.5 MHz – 30 MHz, 73 dB(μV) quasi-peak, 60 dB(μV) average 30 MHz – 230 MHz, 30 dB(μV/m) Quasi-peak at 10 m 230 MHz – 1 000 MHz, 37 dB(μV/m) Quasi-peak at 10 m Or: 30 MHz – 230 MHz, 40 dB(μV/m)...

Open the catalog to page 4
Universal Digital Timer DIN Rail Mount 17.5 mm - 5

| | Universal Digital Timer Function Ac - On/Off Delay (Delay on make/break) Function Ad - Delay on Start Function Ah - Triggered Flashing Cycle (Single shot flip-flop) Function At - Summation time relay Function B - Single Shot (One Shot) Function Bw - Pulse output Function C - Off-Delay (Delay on break) Function D - Flasher (Symmetrical) – OFF Start Function Di - Flasher (Symmetrical) – ON Start

Open the catalog to page 5
Universal Digital Timer DIN Rail Mount 17.5 mm - 6

| | Universal Digital Timer Function Ht - Interval with Memory Function L - Repeat Cycle (Asymmetrical) – OFF Start Function Li - Repeat Cycle (Asymmetrical) – ON Start Function O - Delayed watchdog Function P - Pulse delayed relay Function Pt - Impulse counter (delay on) Function T - On-Delay (Delay on make): sum of times Function TL - Latching (Alternating) – Leading Edge Function Tt - Delayed Latching (Alternating) – Leading

Open the catalog to page 6
Universal Digital Timer DIN Rail Mount 17.5 mm - 7

| | Universal Digital Timer Function W - Timing after pulse of control contact Select button Keys Function Enter to Timing Change Mode Press button less than 3 s Timing change mode Rotate button: change selection / press button: confirm selection

Open the catalog to page 7
Universal Digital Timer DIN Rail Mount 17.5 mm - 8

| Universal Digital Timer Keys Function Enter to Programming Mode Run mode Press button more than 3 s Programming mode Rotate button: change selection / press button: confirm selection Programming Mode Basic Mode - Timer setting in few secondsFUNCTION RANGE COUNT MEMORY • 23 basic functions • Milliseconds -* Days • UP/DOWN • YES/NO Advanced Mode - Optional additional parameters INPUT TYPE LOWER LIMIT INPUT FUNCTION • OFF • Trigger • Reset • Sum • Stop TIME CHANGE UPPER LIMIT SCREEN SAVER DEFAULT RESET Test ModeOUTPUT DISPLAY MEMORY • ON/OFF • TEST • TEST Warning: The product information...

Open the catalog to page 8

All Crouzet catalogs and technical brochures

  1. GN4 Series

    6 Pages

  2. GN2 Series

    8 Pages

  3. Tk2R1

    3 Pages

  4. MLS2

    3 Pages

  5. MLR1

    4 Pages

  6. Mus2

    4 Pages

  7. MCR1

    3 Pages

  8. MAR1

    4 Pages

  9. MUR1

    4 Pages

  10. Millenium 3

    3 Pages

  11. 8D 4R 24VDC

    5 Pages

  12. Syr-Line

    6 Pages

  13. em4 Ethernet

    6 Pages

Archived catalogs