> Up to 46 I/Os - Base 16 DI (4 Highspeed/ 12 AI ), 8 DO + 2 Solid State Relays > Analog Inputs 4-20 mA, 0-10 Vdc and 0-Vdc 12 bits > Ethernet Modbus TCP/IP (Client/Server) and Modbus RTU RS485 via interface (Master/Slave) > Event management & datalog via mail or FTP server > PLC performance with the shape and ease of use of a logic controller Base 26 I/O Ethernet Base 26 I/O Local
Open the catalog to page 1| AUTOMATION.CROUZET.COM | 3 | NANO-PLC | 09/2018
Open the catalog to page 3Digital 24 Vc and analog inputs 12 bits / 28.8 V - potentiometer - 8 inputs from I5 to IC Input used as digital input Input voltage Input current Input impedance Logic 1 voltage threshold Making current at logic state 1 Logic 0 voltage threshold Release current at logic state 0 Response time Sensor type Conforming to IEC/EN 61131-2 Input type Isolation between power supply and inputs Isolation between inputs Protection against polarity inversions Status indicator Cable length Input used as analog input Measuring range Input impedance Maximum value without destruction Input type Resolution 0...
Open the catalog to page 4Yes for voltage < 10 V 2.2 kC / 0.5 W (recommended), 10 KC max. < 10 m with shielded twisted cable (sensor not isolated) Response time Sensor type Conforming to IEC/EN 61131-2 Input type Isolation between power supply and inputs Isolation between inputs Protection against polarity inversions Status indicator Cable length Input used as 0-10 V analog input Measuring range Input impedance Maximum value without destruction Input type Resolution Value of LSB Conversion time Maximum error at 25 °C (77 °F) Maximum error at 55 °C (131 °F) Repeat accuracy at 55 °C (131 °F) Isolation between analogue...
Open the catalog to page 5| AUTOMATION.CROUZET.COM | 6 | NANO-PLC | 09/2018
Open the catalog to page 6EM4B26-ET 8 A relay output - 6 outputs from 05 to OA Breaking voltage Breaking current Maximum breaking current in the common IEC @ 25 °C (77 °F): C3, C6: 8A; C4, C5: 16 A IEC @ 60 °C (140 °F) or UL: C3, C6: 8 A; C4, C5: 10 A Mechanical life Electrical durability for 50 000 operating 24 Vc tau = 0 ms: 8 A, tau = 7 ms: 3 A, tau = 15 ms: 1.5 A cycles Usage category DC-12: 24 V, 8 A Usage category DC-14: 24 V, 1.5 A 250 Va cos phi = 1: 8 A, cos phi = 0.7: 4.75 A, cos phi = 0.4: 3 A Usage category AC-12: 250 V, 8 A Usage category AC-13: 250 V, 4.3 A Usage category AC-15: 250 V, 1.5 A...
Open the catalog to page 71 A (UL248) quick-blowing fuse, circuit-breaker or circuit protector (US) Isolating source Protection / Protection / Schutzschaltung / Protección / Protezione Inductive load
Open the catalog to page 8Warning: The product information contained in this catalogue is given purely as information and does not constitute a representation, warrantly or any form of contractual commitment. Crouzet Automatismes SAS and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsability of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply,...
Open the catalog to page 9All Crouzet catalogs and technical brochures
-
Analog expansion E10A
5 Pages
-
GN4 Series
6 Pages
-
GN2 Series
8 Pages
-
MOTORS & GEARMOTORS
5 Pages
-
SWITCHES & PROXIMITY SENSORS
5 Pages
-
Tk2R1
3 Pages
-
MLS2
3 Pages
-
MLR1
4 Pages
-
Mus2
4 Pages
-
AUTOMATION & CONTROL
6 Pages
-
MCR1
3 Pages
-
MAR1
4 Pages
-
MUR1
4 Pages
-
Millenium 3
3 Pages
-
Compact prewired limit switch
10 Pages
-
8D 4R 24VDC
5 Pages
-
Signal converters
2 Pages
-
USB interface
1 Pages
-
HMI Crouzet Touch Essential
4 Pages
-
OVERVIEW AUTOMATION
16 Pages
-
HMI Crouzet Touch
4 Pages
-
Syr-Line
6 Pages
-
em4 Ethernet
6 Pages
-
Millenium 3 flyer
4 Pages
-
em4 alert flyer
6 Pages
-
Pneumatics products
76 Pages
-
Counters and Ratemeters Crouzet
80 Pages
-
Micro-Control Overview
47 Pages
Archived catalogs
-
MOTORS & GEARMOTORS
5 Pages