GN2 Series - 1

Classic Solid State Relays Panel Mount – Dual channel › 5 and 50 Amps 2 › independent SSRs in one package 2 › ast-on 25 A version available F › nput with Fast-on or 4 pins connector I › ero-Voltage Turn-On and Instantaneous (Random) Turn-On Z › RUus, CE and UKCA Recognized c Fast-on Screw Connection (Marking label 26532004 sold separately) Product Selection - Zero Cross (Resistive Loads) Rated Load Current Output Voltage Product Selection- Instantaneous (Random) (Inductive Loads) Rated Load Current Output Voltage Control Voltage 10-30 Vc PART NUMBERING SYSTEM Part number system Zero Cross Switching Version & Random Switching Version Phases/Channels 8414: Dual Channel Control Voltage 0: 4-32 Vc | Zero Cross 1: 10-30 Vc | Zero Cross 3: 10-30 Vc | Instantaneous Connectivity 0: Fast-on | Zero Cross 1: Screws | Instantaneous 3: Screws | Zero Cross RÉFÉRENCEMENT Do you need an adapted or customized solution? Contact us on www.crouzet.com Phases/Voies Description: Deux voies 8414: Crouzet Solid State Relays are designed to be robust and multipurpose. Tension de commande Génération 0: 4-32 Vc | Synchrone N: Nouvelle génération 1: 10-30 Vc | Synchrone used inVc | Instantanée 3: 10-30 almost any application, offering very long For more information about Crouzet’s Solid State relays, please visit www.crouzet.com. Connectivité 0: Fast-on | Synchrone 1: Vis | Instantanée 3: Vis | Synchrone life expectanc

Open the catalog to page 1
GN2 Series - 3

General Characteristics General Notes (1) All parameters at 25 °C unless otherwise (4) Heatsink required, see derating curves Diagrams Wiring C Star connection (balanced low voltage loads without neutral) O Delta connection (high voltage loads) o Open Delta connection (high voltage loads) It's recommended to use external overvoltage protection (Varistor / TVS Diode) and short-circuit protection (fuse / circuit breaker), if they are not already integrated

Open the catalog to page 3
GN2 Series - 4

| GN2 Series | 04/2023 Connectors Recommended Wire Size Flat head screw 0.6 X 3.5mm DIN5264 DiagramsEquivalent Circuit Block GN2 Series 4-32 Vc control Triac - 24-280 Va -Zero Cross - 84140800N Current Limiter A1 - Input current vs Input Voltage Standard Regulated DC inputs GN2 Series 10-30 Vc control Triac - 24-280 Va -Zero Cross - 84140013N 12 -O- Input current vs Input Voltage Standard Regulated DC inputs 30 25 | 20 15 o | 10 5

Open the catalog to page 4
GN2 Series - 5

GN2 Series 4-32 Vc control Thyristors- 48-660 Va -Zero Cross - 84140603N GN2 Series 10-30 Vc control Thyristors - 24-510 Va -Instantaneous - 84140631N Input current vs Input Voltage Standard Regulated DC inputs 30 GN2 Series 10-30 Vc control Thyristors - 48-660 Va -Zero Cross - 84140613N A2 -O- Input current vs Input Voltage Standard Regulated DC inputs 30

Open the catalog to page 5
GN2 Series - 6

Curves Surge Current Information GN2 - 25 A - 84140013N / 84140800N Itsm (Apeak) Itsm ( Apeak) Itsm (Apeak) No Repetitive Surge Current / Tj initial = 25 °C Repetitive Surge Current / Tj initial = 70 °C No Repetitive Surge Current / Tj initial = 25 °C Repetitive Surge Current / Tj initial = 70 °C No Repetitive Surge Current / Tj initial = 25 °C Repetitive Surge Current / Tj initial = 121 °C

Open the catalog to page 6
GN2 Series - 7

Curves Thermal Derating Curves GN2 - 25 A - 84140013N / 84140800N 25 Amps per channel Total Load Current (Amps) Total Load Current (Amps) Accessories Heatsink 0.9 °C/W Thermal Resistance - 26532752N Accessories Thermal Pad Pre-cut - 26532720N

Open the catalog to page 7
GN2 Series - 8

Accessories Others Screw Mounting Kit - 26532001 Thermal Grease for Heatsink mounting 26532003 Part Number Part Number Standards & Electromagnetic Compatibility Specfification EN60950-1: Meets the requirements of sections 1.5: 1.7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Certified according to EN 62314: 2006 IEC 61000-4-2: Electrostatic Discharge immunity test 8kV air discharge Criterion A Level 3 IEC 61000-4-4: Electrical fast transient/burst immunity test 1kV Line to Line Criterion B Level 3 IEC 61000-4-5: Surge immunity test 1kV Line to Line Criterion B Level 3 Standards Warning: The product...

Open the catalog to page 8

All Crouzet catalogs and technical brochures

  1. GN4 Series

    6 Pages

  2. Tk2R1

    3 Pages

  3. MLS2

    3 Pages

  4. MLR1

    4 Pages

  5. Mus2

    4 Pages

  6. MCR1

    3 Pages

  7. MAR1

    4 Pages

  8. MUR1

    4 Pages

  9. Millenium 3

    3 Pages

  10. 8D 4R 24VDC

    5 Pages

  11. Syr-Line

    6 Pages

  12. em4 Ethernet

    6 Pages

Archived catalogs