Catalog excerpts
The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and display of all electrical parameters including total harmonic distortion (THD) and individual, up to the 63rd harmonic. Display High definition screen features programmable backlight for high contrast visibility in low light and direct sunlight applications. The light can be programmed to automatically dim after set period of time for energy saving. New “petal” array icons shows the percentage of full scale power of the measured system and the instantaneous PF measurement gives clear PF indication. Total power consumption is displayed on the screen at all times. Q2C Wiring Solution INTEGRA 1222 dms and the 3-in-1 current transformers feature Q2C wiring solution for simple yet fast installation utilising plug and socket connections and pre-cut wiring looms, which allow to reduce assembly time and connection errors. IN-OUT voltage connections reduce wiring and installation time. Communication Modbus RS485 RTU and two pulsed outputs are fitted as standard. Enclosure and System The DIN 96 panel mounted enclosure includes integral panel mounting clips for quick and easy fitting and to suit user requirements, the range includes single-phase, three-phase three-wire and three-phase four-wire capability, all selectable at the point of installation. ENERGY /// CROMPTON-INSTRUMENTS.COM Features • DIN 96 enclosure • Programmable backlit LCD screen • Voltage IN-OUT connections • CT current measurement 5A/1A • Plug and socket connections • Programmable VT, CT ratios • Modbus™ RTU • 2 pulsed outputs with led indication • PF bar indicator • 3P4W, 3P3W, 1P2W system types • Individual harmonics to 63rd Benefits • Cost effective • Easy installation • Q2C wiring solution Approvals • IEC BS EN 61010-1:2010 • BS EN 61326-1:2013 • IEC 62053-21 Class 1 • IEC 62053-24 Class 1
Open the catalog to page 1INTEGRA 1222 DIGITAL METERING SYSTEM Displayed Parameters • Voltage per phase L-N, L-L • Current per phase and Max Demand • Power Factor - per phase and system • Total Harmonic Distortion -Voltage and Current per phase • Neutral current • Frequency system • Phase Sequence • Active Power (P) per phase, total and Max Demand • Reactive Power (Q) per phase, total and Max Demand • Apparent Power (S) per phase, total and Max Demand • Energy - Active and Reactive Importing and Total • Energy - Active and Reactive Exporting and Total Pulse Outputs Pulse Outputs Voltage Inputs Voltage Outputs...
Open the catalog to page 2INTEGRA 1222 DIGITAL METERING SYSTEM Specifications Input Parameter Watts L1 Volts L1 Current L1 Active Energy L1 Max Current Demand per phase Imp Active Energy Exp Active Energy Imp Reactive Energy Exp Reactive Energy Total Active Energy Total Reactive Energy
Open the catalog to page 3Q2C WIRING SOLUTION Ensures error free installation and reduces wiring time by 80%. With the Q2C wiring solution, you can quickly and easily connect the INTEGRA 1222 Digital Metering System and 3-in-1 current transformers. Key Benefits • A complete wiring solution with integral connectors and earthing • Screwless terminal connections, vibration proof and maintenance free • Reduced installation time • Eliminates potential cost of errors in electrical connections or programming • Tidy solution for cable management Voltage Meter to Meter_Loom The meter to meter loom connects the voltage...
Open the catalog to page 4INTEGRA 1222 DIGITAL METERING SYSTEM A range of 3-in-1 current transformers to use to use with or without the Q2C wiring solution. The 3-in-1 current transformers combine three traditional current transformers in one moulded case with a connector for simple and easy installation. 76mm wide x 60mm deep x 68mm high Part number QC3N1-35 105mm wide x 38mm deep x 68.5mm high Part number Part number QC3N1-70 212mm wide x 39mm deep x 100mm high ENERGY /// CROMPTON-INSTRUMENTS.COM
Open the catalog to page 5INTEGRA 1222 DIGITAL METERING SYSTEM A range of 3-in-1 current transformers combine three traditional current transformers in one moulded case. 3-in-1 current transformers can be directly installed next to a three-phase moulded case circuit breaker, thus saving installation time where fitting three standard individual current transformers would be required. The M3N1 range of current transformers offers primary currents between 60-630A with 5A secondaries with up to Class 0.5 accuracy performance. Case size: 75mm wide x 60mm deep x 80mm high ENERGY /// CROMPTON-INSTRUMENTS.COM
Open the catalog to page 6INTEGRA 1222 DIGITAL METERING SYSTEM CURRENT TRANSFORMERS RANGE Ebony Current Transformers The range of Crompton Instruments Ebony current transformers offers wide system current ratings, apertures, busbar and case sizes to suit every application. Manufactured to meet EN60044 the range benefits include ratio rating from 1/5 to 6000/5, accuracy up to Class 0.5, integral terminal cover for safety and multiple mounting options. Supplied with metal feet. DIN rail clips and busbar mounting as standard. For use with the CTO range of wiring looms. MR series Current Transformers MR transformers are...
Open the catalog to page 7INTEGRA 1222 DIGITAL METERING SYSTEM About TE Connectivity TE Connectivity Ltd. (NYSE: TEL) TE Connectivity is a $12 billion global technology leader. Our commitment to innovation enables advancements in transportation, industrial applications, medical technology, energy, data communications, and the home. TE’s unmatched breadth of connectivity and sensor solutions, proven in the harshest of environments, helps build a safer, greener, smarter and more connected world. With 75,000 people – including more than 7,000 engineers – working alongside customers in nearly 150 countries, we help...
Open the catalog to page 8All Crompton Instruments catalogs and technical brochures
-
DRS-100-3P
4 Pages
-
Ebony Excel Plus CTs
20 Pages
-
Ebony Excel CTs
24 Pages
-
Integra Ri3
2 Pages
-
Transducers
33 Pages
-
Current Transformers
22 Pages
-
Analogue Instruments
86 Pages
-
Integra DMS Catalogue
67 Pages
-
Product overview
4 Pages
Archived catalogs
-
Protector Trip Relays
52 Pages
-
Energy KWh Meters
18 Pages