1. Catalogs
  2. Critical Process Filtration
  3. Pharma Pleated Fiberglass Depth Capsules

Pharma Pleated Fiberglass Depth Capsules

Pharma Pleated Fiberglass Depth Capsules

Pharma Pleated Fiberglass Depth Capsules

Product catalog summary
Overview: The document provides detailed information about Pharmaceutical Grade PGD Capsule Filters, which utilize pleated fiberglass depth media for filtration. These filters are designed for applications in pharmaceuticals, diagnostics, and water treatment, offering high contaminant holding capacity and 99% retention at rated pore sizes.
Construction Materials: The filters are constructed using polypropylene for the housing, media support, end caps, center core, and outer support cage. The sealing method employed is thermal bonding.
Applications: PGD capsule filters are used in pre-filtration and bioburden reduction for bulk pharmaceutical chemicals, diagnostics, large volume parenterals (LVPs), small volume parenterals (SVPs), ophthalmics, buffers, and water.
Specifications:
  • Liquid Operational Pressure: 80 psi (5.5 bar) at 20°C (68°F)
  • Gases Operational Pressure: 60 psi (4.1 bar) at 20°C (68°F)
  • Operating Temperature: 43°C (110°F) at 30 psi (2.1 bar) in water
  • Forward Differential Pressure: 50 psid (3.4 bard) at 20°C (68°F)
  • Reverse Differential Pressure: 40 psid (2.7 bard) at 20°C (68°F)
  • Recommended Changeout Pressure: 35 psid (2.4 bard)
Flow Rate and Filtration Area: The document includes a table showing typical water flow rates at a one psi pressure differential across various capsule lengths, with filtration areas ranging from 1.0 ft² to 17.4 ft².
Integrity and Compliance: Each capsule is integrity tested before shipment. The materials comply with USP Class VI - 121°C Plastics and FDA regulations for repeated food contact. The filters are non-toxic and meet cytotoxicity and biological reactivity test requirements.
Sanitization/Sterilization: Capsules can be autoclaved at 250°F (121°C) for 30 minutes in multiple cycles and sanitized using industry-standard chemical concentrations. They are not suitable for steam use.
Quality Assurance: Manufacturing adheres to ISO 9001:2008 standards, with real-time monitoring and traceability of materials and processes. Each capsule assembly is tested for integrity before release.
Ordering Information: The document provides a detailed guide for ordering, including options for micron ratings, lengths, sterilization status, and inlet/outlet types.
See more

Catalog excerpts

Pharma Pleated Fiberglass Depth Capsules-1

PGD Capsule Filters Pleated Fiberglass Depth Media Applications LVPs and SVPs Buffers and Other Media PGD capsules are designed using composite media filter modules containing a fiberglass depth media and a final downstream layer of polypropylene depth media to ensure fiber free filtrate. They provide 99% retention at the rated pore size and have high contaminant holding capacity. These cartridges are used in prefilter applications as well as bioburden reduction. Each capsule filtration module is tested for integrity before shipment. Specific applications for PGD capsule filters include pre-filtration of bulk pharmaceutical chemicals, water, buffers, alcohols and other liquids. PGD capsules also are used for bioburden reduction in LVPs, SVPs, diagnostics, ophthalmics, and other final pharmaceutical products. Composite media filter rated at 99% retention at pore size High contaminant holding capacity with excellent retention W ide range of retention ratings Prefiltration and bioburden reduction in bulk chemicals, LVPs, SVPs, water, buffers PGD Capsule Filters - Filtration Area* Capsule Length Pleated Fiberglass Depth *Average – Filtration area varies with media thickness and porosity. Flow Rate / Filtration Area The following table represents typical water flow at a one psi (69 mbar) pressure differential across a single 2 inch capsule with 1.0 ft² (930 cm²) of media with 1/2” FNPT ports. The test fluid is water at ambient temperature. Higher pressure drops are acceptable, but as flows increase the pressure drop of the housing becomes more apparent. Pore Size * For approximate flow rates for 5” through 30” capsules, refer to the appropriate cartridge data sheet Construction Materials Maximum Operating Parameters Liquid Operational Pressure Filtration Media Pleated Fiberglass and Polypropylene Composite Depth Media Gases Operational Pressure Operating Temperature Media Support Forward Differential Pressure 50 psid (3.4 bard) at 20 °C (68 °F) Center Core Reverse Differential Pressure Outer Support Cage Sealing Method Thermal Bonding Recommended Changeout Pressure Pharmaceutical Grade Bulk Pharmaceutical Chemicals Diagnostics

 Open the catalog to page 1
Pharma Pleated Fiberglass Depth Capsules-2

Integrity Test Information Representative sample capsule elements are factory tested for integrity before shipment. Field duplication of these tests is not practical because of the absence of commercial portable testing equipment. The materials used to construct pharmaceutical grade PGD capsule filters are non-toxic and meet the requirements for the MEM Elution Cytotoxicity Test and the requirements for Biological Reactivity Tests in the current version of the United States Pharmacopeia (USP) for Class VI - 121 °C Plastics. In addition, the materials meet the requirements listed by the FDA as...

 Open the catalog to page 2

All Critical Process Filtration catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.