LED Parking Structure Luminaire Product Description Slim, low profile design. Lumianire is constructed from rugged die cast and extruded aluminum components. LED driver is mounted in a sealed weathertight center chamber that allows for access from below the luminaire. High performance aluminum heat sinks specifically designed for LED parking structure application. Performance Summary Utilizes BetaLED® Technology Patented NanoOptic® Product Technology 7.0" (178mm) Made in the U.S.A. of U.S. and imported parts CRI: Minimum 70 CRI CCT: 4000K (+/- 300K), 5700K (+/- 500K) Standard Limited Warranty†: 10 years on luminaire/10 years on Colorfast DeltaGuard® finish Accessories Field-Installed Pendant Mount Kits - Pendant height from ceiling surface to bottom of fixture; mounting accessories or surface boxes will add to overall height XA-PS12KIT – 12" (305mm) XA-PS18KIT – 18" (457mm) XA-PS22KIT – 22" (559mm) Pendant Mount Fitting XA-PSFTG – Pendant Fitting Pendant Mount Leveler XA-PNDTLVL – Leveler for 0-13˚ Sloped Ceilings Hook & Cord Mount Locking Type Plug XA-L515P – 120V XA-L615P – 208/240V XA-L715P – 277V XA-L3720P – 347V Hook & Cord Mount Locking Type Receptacle XA-L515R – 120V XA-L615R – 208/240V XA-L715R – 277V XA-L720R – 347V Hook & Cord Mount Steady Lock SL-C – Steady Lock for Eyebolt Bird Guard XA-XCPBRDGRD – For Pendant or Hook & Cord Mount Only Ordering Information Optic 5M Type V Medium 5S Type V Short PS Petroleum Symmetric SL Sparkle Petroleum 40 40˚ Flood DM Direct HC Hook & Cord PD Pendant Color Options Drive Current SV Silver BK Black BZ Bronze PB Platinum Bronze WH White See www.cree.com/lighting/products/warranty for warranty terms Options 40K 4000K Color Temperature -- Color temperature per luminaire DIM 0-10V Dimming -- Control by others -- Refer to Dimming spec sheet for details -- Can't exceed of specified drive current ML Multi-Level -- Refer to ML spec sheet for availability and additional information -- Intended for downlight applications at 0˚ tilt J Alternate Junction Box Mounting -- For direct mount only
Open the catalog to page 1304 Series™ - LED Parking Structure Luminaire Product Specifications Electrical Data* CONSTRUCTION & MATERIALS • Slim, low profile design Total Current LED Count (x10) • Constructed from rugged die cast and extruded aluminum components • LED driver is mounted in a sealed weathertight center chamber that allows for access from below the luminaire • High performance heat sinks specifically designed for LED parking structure application • Direct mounting bracket is designed to mount directly over existing single gang and octagonal junction boxes for direct mount • Hook and cord mount provided with...
Open the catalog to page 2304 Series™ - LED Parking Structure Luminaire Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified laboratory. To obtain an IES file specific to your project consult: http://www.cree.com/lighting. 5M 150˚ Type V Medium Distribution Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower. 30º ITL Test Report #: 77285 PKG 304 5M ** 06 E UL 700 40K Initial Delivered Lumens: 11,681 Initial Delivered Lumens* CURB LINE Initial Delivered Lumens* Position of vertical plane of maximum candlepower. PKG 304 5M ** 06 E...
Open the catalog to page 3304 Series™ - LED Parking Structure Luminaire Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified laboratory. To obtain an IES file specific to your project consult: http://www.cree.com/lighting. PS 150˚ Petroleum Symmetric Distribution Position of vertical plane of maximum candlepower. ITL Test Report #: 76940 CAN 304 PS ** 06 E UL 700 40K Initial Delivered Lumens: 13,581 CURB LINE Initial Delivered Lumens* 1357 Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower. Initial Delivered Lumens* PKG 304 PS...
Open the catalog to page 4304 Series™ - LED Parking Structure Luminaire Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified laboratory. To obtain an IES file specific to your project consult: http://www.cree.com/lighting. 40˚ 16598 Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower. ITL Test Report #: 78011 CAN 304 40 ** 06 E UL 700 40K Initial Delivered Lumens: 12,497 Initial Delivered Lumens* Initial Delivered Lumens* PKG 304 40 ** 06 E UL 700 40K Mounting Height: 15' (4.6m) Initial Delivered Lumens: 12,917 Initial FC at grade...
Open the catalog to page 527 Pages
43 Pages
25 Pages
31 Pages
30 Pages
54 Pages
30 Pages
26 Pages
12 Pages
20 Pages
10 Pages
10 Pages
39 Pages
22 Pages
8 Pages
3 Pages
6 Pages
5 Pages
35 Pages
19 Pages
172 Pages
24 Pages
6 Pages
21 Pages
27 Pages
2 Pages
28 Pages
2 Pages
10 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
10 Pages
13 Pages
12 Pages
17 Pages
13 Pages
19 Pages
17 Pages
12 Pages
10 Pages
13 Pages
11 Pages
11 Pages
12 Pages
28 Pages
12 Pages
19 Pages
11 Pages
2 Pages
4 Pages
156 Pages
6 Pages
13 Pages