Product Description Slim, low profile design. Luminaire is constructed from rugged die cast and extruded aluminum components. LED driver is mounted in a sealed weathertight center chamber that allows for access from below the luminaire. High performance heat sinks specifically designed for LED floodlight application. Luminaire mounts with stainless steel adjustable yoke mount which allows for +/- 90" adjustment in 5" increments. Applications: Underpasses and sign lighting Performance Summary Patented NanoOptic® Product Technology Made in the U.S.A. of U.S. and imported parts CRI: Minimum 70 CRI CCT: 4000K (+/- 300K), 5700K (+/- 500K) standard Limited Warranty*: 10 years on luminaire/10 years on Colorfast DeltaGuard® finish f See http://lighting.cree.com/warranty for warranty terms Accessories Field-installed Multi-Level Sensor location (ordered as an option) Hand-Held Remote XA-SENSREM - For successful implementation of the programmable multi-level option, a minimum of one hand-held remote is required Ordering information Example: FLD-304-2M-YM-04-E-UL-SV-350 Canada: www.cree.com/canada CREEt: T (800) 473-1234 F (800) 890-7507
Open the catalog to page 1Product Specifications CONSTRUCTION & MATERIALS • Slim, low profile design • Luminaire is constructed from rugged die cast and extruded aluminum components • LED driver is mounted in a sealed weathertight center chamber that allows for access from below the luminaire • 3' (0.9m) SEOW cord exits street side of luminaire through 1/2" (13mm) NPT cable gland • High performance aluminum heat sinks specifically designed for LED floodlight applications • Luminaire mounts with stainless steel adjustable yoke which allows for +/- 90' adjustment in 5' increments • Exclusive Colorfast DeltaGuard® finish...
Open the catalog to page 2Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool 2M Type II Medium Distribution * Initial delivered lumens at 25‘C (77‘F). Actual production yield may vary between -10 and +10% of initial delivered lumens ’’ For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt US: lighting.cree.com/lighting T (800)...
Open the catalog to page 3Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool 5M Type V Medium Distribution * Initial delivered lumens at 25‘C (77‘F). Actual production yield may vary between -10 and +10% of initial delivered lumens ’’ For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt US: lighting.cree.com/lighting T (800)...
Open the catalog to page 4Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool SL Sparkle Petroleum Distribution * Initial delivered lumens at 25‘C (77‘F). Actual production yield may vary between -10 and +10% of initial delivered lumens ’’ For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt FLD-EDG-SN-**-06-E-UL-700 Mounting...
Open the catalog to page 5Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool N6 * Initial delivered lumens at 25‘C (77‘F). Actual production yield may vary between -10 and +10% of initial delivered lumens * Initial delivered lumens at 25‘C (77‘F). Actual production yield may vary between -10 and +10% of initial delivered lumens FLD-304-N6-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G., 60° Tilt Initial Delivered Lumens:...
Open the catalog to page 6Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool 25" * Initial delivered lumens at 25‘C (77‘F). Actual production yield may vary between -10 and +10% of initial delivered lumens * Initial delivered lumens at 25‘C (77‘F). Actual production yield may vary between -10 and +10% of initial delivered lumens FLD-304-25-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G., 60° Tilt Initial Delivered Lumens:...
Open the catalog to page 7Photometry All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Tools-and-Support/Exterior-IES-Configuration-Tool 70" CESTL Test Report #: 2014-0007 FLD-EDG-70-**-04-E-UL-350-40K Initial Delivered Lumens: 4,734 * Initial delivered lumens at 25‘C (77‘F). Actual production yield may vary between -10 and +10% of initial delivered lumens FLD-304-70-**-06-E-UL-700 Mounting Height: 25' (7.6m) A.F.G., 60° Tilt Initial Delivered Lumens: 12,221 Initial FC at grade...
Open the catalog to page 827 Pages
43 Pages
25 Pages
31 Pages
30 Pages
54 Pages
30 Pages
26 Pages
12 Pages
20 Pages
10 Pages
10 Pages
39 Pages
22 Pages
3 Pages
6 Pages
5 Pages
35 Pages
19 Pages
172 Pages
24 Pages
6 Pages
21 Pages
27 Pages
5 Pages
2 Pages
28 Pages
2 Pages
10 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
10 Pages
13 Pages
12 Pages
17 Pages
13 Pages
19 Pages
17 Pages
12 Pages
10 Pages
13 Pages
11 Pages
11 Pages
12 Pages
28 Pages
12 Pages
19 Pages
11 Pages
2 Pages
4 Pages
156 Pages
6 Pages
13 Pages