video corpo

mda-sales-documentation-uk
2Pages

{{requestButtons}}

Catalog excerpts

mda-sales-documentation-uk - 1

engine / genset control automatic start MDA Automatic start unit • Simple and basic unit • 50/60 Hz compatibility • Basic engine protection • Preheat or “Energize to stop” output The MDA unit from CRE Technology is a basic, microprocessor controlled unit designed to start and stop the genset automatically on request of an external Remote Start signal. It has high power relay outputs enabling it to interface directly with diesel gensets. A SIMPLE PRODUCT FOR BASIC FUNCTIONS When the engine is running, the unit monitors fault conditions and shuts down the engine automatically if an alarm occurs. The alarms are identified with LEDs which display the first one to occurr. On an OFF position, the module is de-energized and the remote start is disabled with no current consumption. The unit uses high current two part connectors for easy replacement. ENERGIZE TO STOP CONTROL The MDA is also able to control ‘Energize to Stop’ engines. When the ‘Energize to Stop’ option is selected, the auxiliary relay output will be energized during the stop timer and the led associated with this condition will be switched on. The selection of engine type is made by a jumper switch. The unit is able to operate with both 50 and 60 Hz systems. The selection is made with a jumper switch. The MDA is dedicated to basic applications which need no extra costs or expensive hardware. CRE Technology has just added two things: Reliability and After Sales Service. All CRE Technology products aim to provide the same satisfaction levels. The MDA has passed EMC and Low Voltage tests, and all units are 100% tested before delivery. AFTER SALES SERVICE Like every CRE Technology product, the unit also benefits from our technical support. All CRE products are delivered with one year warrant

Open the catalog to page 1
mda-sales-documentation-uk - 2

OUTPUTS • Fuel solenoid: 10amps@28V-DC. • Start: 10amps@28V-DC. • Auxiliary: 10amps@28V-DC. INPUTS • DC supply: 12 or 24 volts DC, (+) and (-) terminals. • L1: generator phase voltage. • Neutral: Generator neutral terminal. • High temp switch: negative closing switch input. • Low oil pressure: negative closing switch input. • Remote start: a negative supply connected to this input will run the engine. • Charge: connect the charge alternator's D+ output to this terminal. This terminal will supply the excitation current and measure the voltage of the charge alternator. OPTIONS • Preheat with...

Open the catalog to page 2

All CRE TECHNOLOGY catalogs and technical brochures

  1. I4GEN suite

    2 Pages

  2. I4GEN.10

    2 Pages

  3. ICGEN2.0

    55 Pages

  4. SCR 2.0

    19 Pages

  5. C2S

    16 Pages

  6. BP range

    2 Pages

  7. i4GEN

    2 Pages

  8. avrcompact

    2 Pages

  9. Synchro Compact

    144 Pages