1. Catalogs
  2. CRE TECHNOLOGY
  3. mda-sales-documentation-uk

mda-sales-documentation-uk

mda-sales-documentation-uk

mda-sales-documentation-uk

Product catalog summary
Overview: The MDA is a basic, microprocessor-controlled unit designed for automatic start and stop of gensets upon receiving an external Remote Start signal. It is suitable for basic applications requiring no additional costs or complex hardware.
Key Features:
  • Monitors engine fault conditions and automatically shuts down the engine if an alarm occurs, with alarms indicated by LEDs.
  • Compatible with both 50 and 60 Hz systems, selectable via a jumper switch.
  • Supports 'Energize to Stop' engines, with an auxiliary relay output energized during the stop timer.
  • High power relay outputs for direct interfacing with diesel gensets.
  • Passed EMC and Low Voltage tests, ensuring reliability.
Environmental Specifications:
  • Operating temperature: -20°C to 70°C (-4°F to 158°F).
  • Storage temperature: -30°C to 80°C (-22°F to 176°F).
  • Maximum humidity: 95% non-condensing.
Physical Specifications:
  • Dimensions: 72x72x38mm.
  • Panel cut-out dimensions: 68x68 mm.
  • Weight: Approximately 140g.
Electrical Characteristics:
  • Alternator voltage range: 15 to 300 V-AC.
  • Alternator frequency: 50 or 60 Hz nominal.
  • DC Supply Range: 8 to 33 V-DC.
  • Current consumption: 80mA max with outputs open.
Start/Stop Sequence:
  • Preheat delay: 10 seconds.
  • Start duration: 6 seconds.
  • Cooldown duration: 2 minutes.
  • Stop timer: 30 seconds.
Outputs:
  • Fuel solenoid, Start, and Auxiliary outputs: 10amps@28V-DC each.
Inputs:
  • DC supply: 12 or 24 volts DC.
  • High temp switch and Low oil pressure: negative closing switch inputs.
  • Remote start: negative supply input to run the engine.
Options:
  • Preheat with activate to start.
  • Energize to stop without preheat.
Additional Information:
  • Part Number: A60Y1.
  • Software: Rainbow 2.026.
  • Associated Products: MDA PLUS (Advanced), UNIGEN FAMILY (Complementary).
After Sales Service: The unit comes with a one-year warranty and benefits from CRE Technology's technical support.
See more

Catalog excerpts

mda-sales-documentation-uk-1

engine / genset control automatic start MDA Automatic start unit • Simple and basic unit • 50/60 Hz compatibility • Basic engine protection • Preheat or “Energize to stop” output The MDA unit from CRE Technology is a basic, microprocessor controlled unit designed to start and stop the genset automatically on request of an external Remote Start signal. It has high power relay outputs enabling it to interface directly with diesel gensets. A SIMPLE PRODUCT FOR BASIC FUNCTIONS When the engine is running, the unit monitors fault conditions and shuts down the engine automatically if an alarm occurs. The alarms are identified with LEDs which display the first one to occurr. On an OFF position, the module is de-energized and the remote start is disabled with no current consumption. The unit uses high current two part connectors for easy replacement. ENERGIZE TO STOP CONTROL The MDA is also able to control ‘Energize to Stop’ engines. When the ‘Energize to Stop’ option is selected, the auxiliary relay output will be energized during the stop timer and the led associated with this condition will be switched on. The selection of engine type is made by a jumper switch. The unit is able to operate with both 50 and 60 Hz systems. The selection is made with a jumper switch. The MDA is dedicated to basic applications which need no extra costs or expensive hardware. CRE Technology has just added two things: Reliability and After Sales Service. All CRE Technology products aim to provide the same satisfaction levels. The MDA has passed EMC and Low Voltage tests, and all units are 100% tested before delivery. AFTER SALES SERVICE Like every CRE Technology product, the unit also benefits from our technical support. All CRE products are delivered with one year warrant

 Open the catalog to page 1
mda-sales-documentation-uk-2

OUTPUTS • Fuel solenoid: 10amps@28V-DC. • Start: 10amps@28V-DC. • Auxiliary: 10amps@28V-DC. INPUTS • DC supply: 12 or 24 volts DC, (+) and (-) terminals. • L1: generator phase voltage. • Neutral: Generator neutral terminal. • High temp switch: negative closing switch input. • Low oil pressure: negative closing switch input. • Remote start: a negative supply connected to this input will run the engine. • Charge: connect the charge alternator's D+ output to this terminal. This terminal will supply the excitation current and measure the voltage of the charge alternator. OPTIONS • Preheat with activate...

 Open the catalog to page 2

All CRE TECHNOLOGY catalogs and technical brochures

  1. Paralleling

    6  Pages

  2. Hybrid range

    6  Pages

Archived catalogs

  1. I4GEN suite

    2  Pages

  2. I4GEN.10

    2  Pages

  3. BTB COMPACT

    4  Pages

  4. SCR 2.0

    2  Pages

  5. i4GEN

    2  Pages

  6. BP range

    2  Pages

  7. C2S

    16  Pages

  8. ICGEN2.0

    55  Pages

  9. avrcompact

    2  Pages

  10. Synchro Compact

    144  Pages

  11. COMPACT RANGE

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.