video corpo

gensys compact range comparison en a2018
1Pages

{{requestButtons}}

Catalog excerpts

gensys compact range comparison en a2018 - 1

Panel cut out Size Weight Front/Back panel protection Operating temperature LCD caracteristics Type of paralleling Number of discrete inputs Analog inputs Digitals outputs Magnetic pick up input Possibility of digital inputs/outputs extensions (on CANopen) Possibility of analog inputs/outputs extensions (on CANopen) 220 x 160 mm 245 x 182 x 40mm _0,7Kg_ IP 65/ IP20 -20°C / +70°C 80x54mm - 128x64 pixels "Only between generators set" 32 9 3 : 0-500Ohms or 0-20mA 8 Yes 32DI/32DO 0E/0S Between generators or 1 generator with mains" Several generators with one or several mains" Generator breaker control Power plant breaker control Mains breaker control Engine control with PWM signal Engine control/measure with CAN J1939 Measurement voltage (100 - 480VAC) - Single/BI/Three phases Measurement current (1 - 5A) - Single/BI/Three phases Three-phase current junction Full manu mode (synchro, load share KW, KVAR,...) Active paralleling / Static paralleling kW Sharing by analog parallel lines Limit alarm/fault Phase shift compensation (type DYN11) Watchdog digital output Tie Breaker management Yes No No No Yes 3 GE (4 wires) + 3 Bus (3 wires) 3 Generators 4 wires No Yes / Yes No 2 adjustable limits No No No Yes No Yes No Yes 3 GE (4 wires) + 3 Mains (3 wires) 3 Generators + 1 Mains 4 wires No Yes / Yes No 2 adjustable limits No No No Remote supervision (with BSD 2.0 opt.) Send mail/text message about event (with bsd 2.0 opt.) Geographical localisation with security perimeter (with BSD 2.0 opt.) Yes Yes Yes Yes NA Yes Yes Yes 3 GE (4 wires) + 3 Bus/Reseau (3 fils) 3 Generators + 3 Bus/mains 6 wires Yes (free option) Yes / Yes Yes 1 limit + unlimited with PLC Yes Yes (option) Yes Yes Yes Yes NA Yes Yes Yes Yes 3 Bus (4 wires) + 3 Mains (3 wires) 3 Bus + 3 mains 6 wires Yes (free option) NA Yes 1 limit + unlimited with PLC Yes Yes (option) NA Yes Yes Yes Ethernet port (isolated, PC connections Modbus TCP read/write) CANbus port (isolated, CANopen + J1939 + CAN inter-modules) RS485 port (isolated, modbus RTU read/write) SD card (SD & SDHC FAT 16/32) Alarms memory (on screen) Fault memory (on screen) Alarms/Fault memories (on PC) Storage on SD card (timer mini = 1s) Generator electrical protection (F, U, I, KW,KVAR,...) Earth fault protection Short circuit protection Operating/Configuration with PC (CREConfig) Programming Languages 1 2 0 No 15 actives + last 30 15 actives + last 30 1365 No Yes Yes Yes Yes Yes (EasyFlex) Up to 10 languages 1 2 0 No 15 actives + last 30 15 actives + last 30 1365 No Yes Yes if mains is not used Yes Yes Yes (EasyFlex) Up to 10 languages Up to 32Go Yes Yes if mains is not used No Yes Yes (EasyPLC) 3 permanent languages + 1 configurable language Up to 32Go Yes No No Yes Yes (EasyPLC) 3 permanent languages + 1 configurable language CRE TECHNOLOGY - 130, allee Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE Phone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com

Open the catalog to page 1

All CRE TECHNOLOGY catalogs and technical brochures

  1. I4GEN suite

    2 Pages

  2. I4GEN.10

    2 Pages

  3. ICGEN2.0

    55 Pages

  4. SCR 2.0

    19 Pages

  5. C2S

    16 Pages

  6. BP range

    2 Pages

  7. i4GEN

    2 Pages

  8. avrcompact

    2 Pages

  9. Synchro Compact

    144 Pages