video corpo

GENSYS COMPACT PRIME SALES DOCUMENTATION
4Pages

{{requestButtons}}

Catalog excerpts

GENSYS COMPACT PRIME SALES DOCUMENTATION - 1

GEN PRIME All-in-one s hronizing & parallel The GENSYS COMPACT PRIME is made for gensets used in power plant applications requiring synchronizing, active and reactive load sharing and electrical/mechanical protections. GENSYS COMPACT PRIME offers flexibility and time saving thanks to its simple wiring, all features included (no option), and easy engineering & programming. HARDWARE & DISPLAY GENSYS COMPACT PRIME is available in both switchboard panel mounted version with display, or core base mounted version. And compatible with i4GEN touchscreen color display. SOFTWARE GENSYS COMPACT PRIME is configurable from its front panel display, from i4GEN, or through the free CRE PC software. CORE BASE MOUNTED VERSION SWITCHBOARD MOUNTED VERSION WITH DISPLAY FEATURES CONTROL AND MANAGEMENT • Complete engine control of diesel, gasoline or gas gensets (preheating, pre-glow, ignition, start/stop.. • Alternative or consecutive multiple starter management. • Warmup & Cool down at idle or nominal speed. • Remote start and test mode available ON/OFF load. • Compatible with all J1939 electronic engines. • Isochronous and Iso-voltage active & reactive load sharing. • Fixed kW/KVAR load or Droop mode. • Frequency and voltage control compensation for generators with droop governors and/or AVR/DVR. • Synchronization and dead bus management: • Static synchronization: gensets breakers closing without excitation. • Dynamic synchronization: Frequency, Phase & Voltage synchronization (Synch display available on screen). Synch Check (ANSI 25) + Phase sequence protection. • New optimized PID loop with exceptional performance in synchronization, KW and KVAR control. • Override mode (protections inhibition + dedicated hour meter) following NFE 37-312 certification. • Non-essential load control on overload. • Battery Boost management. • Configurable maintenance cycle. • 2 passwords levels. DISPLAYED INFORMATIONS • Engine parameters: oil pressure, coolant temperature, speed, running hours meters (override & safe conditions), number of start attempts, battery voltage. and all J1939 values available on ECUs. • Generator electrical parameters: • Voltage (3 phases RMS, L-L & L-N) • Current (3 phases RMS) • Frequency • Active power (3 phases + total) • Reactive power (3 phases + total) • Power factor (3 phases + total) • Calculated active energy (kWh) • Calculated reactive energy (kWARh) • Bus electrical parameters: • Voltage (3 phases RMS, L-L & L-N) • Frequency • Active & reactive power (calculated) • Synchroscope & synch check relay authorization values. • Log of fault & alarms with timestamp & real-time value. • Configurable event logger and info pages. • Automatic clock synchronization by CAN bus. EVENTS LOGGER • 1350 logged fault & alarms with timestamp & real-time value, on a nonvolatile memory. • The last 30 logged alarms/faults & 15 active alarms/ faults are available on front panel display. ELECTRICAL PROTECTIONS • Generator electrical protections: • <F, >F : ANSI Code 81L, 81H • <U, >U : ANSI Code 27, 59 • >I, >>I, >In, Ig : ANSI Code 50, 51,50N, 51G • <KW, >KW, -KW : ANSI Code 37P, 32P, 32RP • <KVAR, >KVAR, -kVAR : ANSI Code 37Q, 32Q, 32RQ • Bus electrical protections: • <F, >F : ANSI Code 81L, 81H • <U, >U : ANSI Code 27, 59 BREAKERS CONTROL • Adjustable Pulses or latched contact for breaker closing. • Adjustable Pulses or latched contact for breaker opening. • MN/MX coil management. PROGRAMMING FEATURES • Alternative selection: up to 16 parameters values can be modified by triggering any digital input or Modbus variable. • Scheduler: Specific functions or modes (ex: auto start, test MODE, Boost,.) can be programmed on scheduled operation (cyclic or one-time). • Easyflex: • 50 lines of programming with Logic & Arithmetic operators and conditions • All inputs/outputs and variables available • Generic filling feature: • High and low set point from digital or analog input • Up or down direction configurable AUTOMATIC FIRMWARE UPDATE When module is connected to CRE PC software, you will automatically be asked for a firmware update to the latest version if applicable. MODBUS TCP SLAVE COMMUNICATION PORT • All data are accessible by Modbus TCP locally or remotely (web, GPRS). • Read and write functions + 300 free Modbus address available for custom mapping. REMOTE SUPERVISION WITH BSD 2.0 MODULE (CLOUD TECHNOLOGY) • Geolocalisation: you can see from your PC or smartphone the localization of your complete gensets fleet. • Geo Fencing: In case of genset moving beyond a configurable limit, you will be informed by message. • Monitoring and control of the genset. • Alert messages (SMS, emails). • Up to 8 users access levels. • Free Cloud license. Part number: A56-PRIME-10-A CORE base mounted version Part number: A56-PRIME-00-A Switchboard mounted version with display RELATED PRODUCTS & CABLES i4GEN Touchscreen color display - Ref A56 Vxx MASTER COMPACT - A56-MAST Additional I/O - Ref LC5100 + KL1488 + KL2408 ... PC Connection Ethernet cable - Ref A53W1 CAN bus J1939/CRE/CAN open communication cable - Ref A40xx Remote monitoring gateway BSD2.0 - Ref A61Y2 Demonstration suitcase - Ref A56X1 CRE TECHNOLOGY - 130, allee Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE Phone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com -

Open the catalog to page 1
GENSYS COMPACT PRIME SALES DOCUMENTATION - 2

APPLICATIONS GENSYS COMPACT PRIME is well-suited for any application requiring paralleling of 2 gensets or more (up to 32), and an automatic management of load control, synchronization process (on live bus bar or dead bus bar), load dependent start/stop and protections. GENSYS COMPACT PRIME is able to manage diesel or gas engine start & stop sequences, as well as interfacing with Auto-Start controllers and ECUs, by using I/Os or J1939 CAN bus protocol. GENSYS COMPACT PRIME offers also an Ethernet port for PC connection and MODBUS TCP connection for supervising purposes (BMS). Synchronizing...

Open the catalog to page 2

All CRE TECHNOLOGY catalogs and technical brochures

  1. I4GEN suite

    2 Pages

  2. I4GEN.10

    2 Pages

  3. ICGEN2.0

    55 Pages

  4. SCR 2.0

    19 Pages

  5. C2S

    16 Pages

  6. BP range

    2 Pages

  7. i4GEN

    2 Pages

  8. avrcompact

    2 Pages

  9. Synchro Compact

    144 Pages