video corpo

GENSYS COMPACT MAINS SALES DOCUMENTATION
4Pages

{{requestButtons}}

Catalog excerpts

GENSYS COMPACT MAINS SALES DOCUMENTATION - 1

GENSYS COMPACT MAINS All-in-one generator controller and mains paralleling unit The GENSYS COMPACT MAINS is used on standalone generator in mains paralleling application. GENSYS COMPACT MAINS offers flexibility and time saving thanks to its simple wiring, all features included (no option), and easy programming. HARDWARE DISPLAY GENSYS COMPACT MAINS is available in both switchboard panel mounted version with display, or core base mounted version and compatible with i4GEN touchscreen color display. SOFTWARE GENSYS COMPACT MAINS is configurable from its front panel display, from i4GEN, or through the free CRE PC software. CORE BASE MOUNTED VERSION SWITCHBOARD MOUNTED VERSION WITH DISPLAY FEATURES CONTROL AND MANAGEMENT • Complete engine control of diesel, gasoline or gas generators (preheating, pre-glow, ignition, start/stop…). • Alternative or consecutive multiple starter management. • Warm-up and cool down at idle or nominal speed. • Remote start and test mode available On/Off load. • Compatible with all J1939 electronic engines. • Mains failure detection and No Break changeover with adjustable load transfer time and paralleling time. • Possibility of operator mains transfer validation. • Mains permanent paralleling in fix load and PF control. Isochronous and Iso-voltage or droop mode. • Frequency and voltage control, compensation for generators with droop governors and/or AVR/DVR. • Synchronization: Frequency, Phase and Voltage synchronization (Synch display available on screen). Synch check (ANSI 25) + Phase sequence protection. • New optimized PID loop with exceptional performance in synchronization, KW and KVAR control. • Override mode (protections inhibition + dedicated hour meter) following NFE 37-312 certification. • Non-essential load control on overload. • Battery boost management. • Configurable maintenance cycle. • 2 password levels. DISPLAYED INFORMATIONS • Engine parameters: oil pressure, coolant temperature, speed, hour run meters (normal and override), number of start attempts, battery voltage,… and all J1939 values available on ECUs. • Generator electrical parameters: • Voltage (3 phases RMS, L-L and L-N) • Current (3 phases RMS) • Frequency • Active power (3 phases + total) • Reactive power (3 phases + total) • Power factor (3 phases + total) • Calculated active energy (KWh) • Calculated reactive energy (KWARh) • Mains electrical parameters: • Voltage (3 phases RMS, L-L and L-N) • Frequency • Current (1 phase RMS) • Active and reactive power • Power factor • Synchroscope and synch check relay authorization values. • Log of alarms and faults with timestamps and real-time values. • Configurable event logger and info pages. EVENTS LOGGER • 1350 logged events with timestamp and real-time value, on a non volatile memory. • The last 30 logged alarms/faults and 15 active alarms/ faults are available on front panel display. ELECTRICAL PROTECTIONS • Generator electrical protections: • F: ANSI Code 81L, 81H • U: ANSI Code 27, 59 • >I, >>I, >In, Ig: ANSI Code 50, 51, 50N, 51G • KW, -KW: ANSI Code 37P, 32P, 32RP • KVAR, -KVAR: ANSI Code 37Q, 32Q, 32RQ • Mains electrical protections: • F: ANSI Code 81L, 81H • U: ANSI Code 27, 59 • KW, -KW: ANSI Code 37P, 32P, 32RP • KVAR, -KVAR: ANSI Code 37Q, 32Q, 32RQ • Vector Jump, ROCOF: ANSI Code 78, 81 • All inputs/outputs and variables available • Generic filling feature: • High and low set point from digital or analog input • Up or down direction configurable AUTOMATIC FIRMWARE UPDATE When module is connected to CRE PC software, you will automatically be asked for a firmware update to the latest version if applicable. MODBUS TCP SLAVE COMMUNICATION PORT • All data are accessible by Modbus TCP locally or remotely (web, GPRS). • Read and write functions + 300 free Modbus TCP addresses available for custom mapping. REMOTE SUPERVISION WITH BSD 2.0 MODULE (CLOUD TECHNOLOGY) • Geolocalisation: you can see from your PC or smartphone the localization of your complete generators fleet. • Geo Fencing: In case of generator moving beyond a configurable limit, you will be informed by message. • Monitoring and control of the generator. • Alert messages (SMS, emails). • Up to 8 users access levels. • Free Cloud license. BREAKERS CONTROL • Adjustable pulses or latched contact for breaker closing. • Adjustable pulses or latched contact for breaker opening. • MN/MX coil management. PROGRAMMING FEATURES • Alternative selection: up to 16 parameters values can be modified by triggering any digital input or Modbus TCP variable. • Scheduler: Specific functions or modes (ex: auto start, test mode Boost…) can be programmed on scheduled operation (cyclic or one-time). • Easy Flex®: • 50 lines of programming with logic and arithmetic operators, and conditions Part numbers: A56-MAINS-10-A Core base mounted version A56-MAINS-00-A Switchboard mounted version with display RELATED PRODUCT AND CABLES i4GEN Touchscreen color display – Ref A56Vxx Additional I/O – Ref LC5100 + KL1488 + KL2408 … PC Connection Ethernet cable – Ref A53W1 CANbus J1939/CRE/CANopen communication cable – Ref A40xx Remote monitoring gateway BSD2.0 – Ref A61Y2 Demonstration suitcase – Ref A56X1 CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Tem

Open the catalog to page 1
GENSYS COMPACT MAINS SALES DOCUMENTATION - 2

APPLICATIONS GENSYS COMPACT MAINS suits for all standby generator requiring the capability of synchronizing with mains power, controlling active and reactive load with mains power as well as electrical and engine protections, and moreover an automatic management of the installation; examples: • Changeover application on mains failure: Unit monitor mains and start generator automatically on mains failure to supply backup power; once mains (utility) is back to normal conditions, GENSYS COMPACT MAINS will transfer the load after synchronizing with mains (No Break changeover). Mains paralleled...

Open the catalog to page 2

All CRE TECHNOLOGY catalogs and technical brochures

  1. I4GEN suite

    2 Pages

  2. I4GEN.10

    2 Pages

  3. ICGEN2.0

    55 Pages

  4. SCR 2.0

    19 Pages

  5. C2S

    16 Pages

  6. BP range

    2 Pages

  7. i4GEN

    2 Pages

  8. avrcompact

    2 Pages

  9. Synchro Compact

    144 Pages