video corpo

COMPACT RANGE
4Pages

{{requestButtons}}

Catalog excerpts

COMPACT RANGE - 1

The COMPACT RANGE offers the following single or combined features: synchronizing, active and reactive load sharing, fixed power, fixed frequency or voltage, load dependent start/stop management, and protections. The COMPACT RANGE offers flexibility and time saving thanks to its simple wiring, all features included (no option), and easy engineering & programming. HARDWARE & DISPLAY The COMPACT RANGE is a new generator controller range available in both switchboard panel mounted version with display, or core base mounted version. The COMPACT RANGE is also compatible with i4GEN touchscreen color display. SOFTWARE The COMPACT RANGE is configurable from its front panel display, remote touchscreen, or through the free CRE PC software. FEATURES CONTROL AND MANAGEMENT • Compatible with all engines ECUs in J1939, speed governors, alternators and AVRs/DVRs voltage regulators. • Isochronous and Iso-voltage active & reactive load sharing. 1 • Fixed kW/KVAR load or Droop mode. 1 • Frequency and voltage control compensation for generators with droop governors and/or AVR/DVR. 1 • Synchronization and dead bus management. 2 • Static synchronization: gensets breakers closing without excitation. 1 • Dynamic synchronization: Frequency, Phase & Voltage synchronization (Synch display available on screen). Synch Check (ANSI 25) + Phase sequence protection. 2 • New optimized PID loop with exceptional performance in synchronization and load control. • Load shedding: Non-essential load control on overload. 1 • Load dependent start/stop: only the needed numbers of gensets are running. 1 2 • 2 passwords levels. DISPLAYED INFORMATIONS Generator electrical parameters: • Voltage (3 phases RMS, L-L & L-N) • Current (3 phases RMS) 1 • Frequency • Active power (3 phases + total) 1 • Reactive power (3 phases + total) 1 • Power factor (3 phases + total) 1 • Calculated active energy (kWh) 1 • Calculated reactive energy (kWARh) 1 Bus electrical parameters: • Voltage (3 phases RMS, L-L & L-N) 1 • Frequency 2 • Active & reactive power (calculated) 2 • Synchroscope & synch check relay authorization values.2 • Log of fault & alarms with timestamps & real-time values. • Configurable event logger and info pages. • Automatic clock synchronization by CAN bus. EVENTS LOGGER • 1350 logged fault & alarms with timestamp & real-time value, on a nonvolatile memory. • The last 30 logged alarms/faults & 15 active alarms/ faults are available on front panel display. ELECTRICAL PROTECTIONS: • Generator electrical protections: • <F, >F : ANSI Code 81L, 81H • <U, >U : ANSI Code 27, 59 • >I, >>I, >In, Ig : ANSI Code 50, 51,50N, 51G 1 • <KW, >KW, -KW : ANSI Code 37P, 32P, 32RP 1 • <KVAR, >KVAR, -kVAR : ANSI Code 37Q, 32Q, 32RQ 1 • Mains/bus electrical protections: • <F, >F : ANSI Code 81L, 81H 1 • <U, >U : ANSI Code 27, 59 1 • <KW, >KW, -KW : ANSI Code 37P, 32P, 32RP 1 • <KVAR, >KVAR, -kVAR : ANSI Code 37Q, 32Q, 32RQ 1 • Vector Jump, ROCOF : ANSI Code 78, 81 1 2 BREAKERS CONTROL • Adjustable Pulses or latched contact for breaker closing. • Adjustable Pulses or latched contact for breaker opening. • MN/MX coil management. PROGRAMMING FEATURES • Alternative selection: up to 16 parameters values can be modified by triggering any digital input or Modbus variable. • Scheduler: Specific functions or modes (ex: auto start, test MODE, Boost,...) can be programmed on scheduled operation (cyclic or one-time). • Easyflex: • 50 lines of programming with Logic & Arithmetic operators and conditions • All inputs/outputs and variables available AUTOMATIC FIRMWARE UPDATE: When module is connected to CRE Config software, you will automatically be asked for a firmware update to the latest version if applicable. MODBUS TCP SLAVE COMMUNICATION PORT • All data are accessible by Modbus TCP locally or remotely (web, GPRS). • Read and write functions + 300 free Modbus address available for custom mapping. COMPATIBILITY Need additional CAN bus to paralleling lines interface for compatibility with Barber Colman, Woodward, DEIF, Comap, Deep Sea,. Notes : 1 : Not on SYNCHRO COMPACT 2 : Not on ILS COMPACT Part number A56-SYNCH-10-A: SYNCHRO COMPACT CORE version Part number A56-SYNCH-00-A: SYNCHRO COMPACT switchboard version with display Part number A56-ILS-10-A: ILS COMPACT CORE version Part number A56-ILS-00-A: ILS COMPACT switchboard version with display Part number A56-PMS-10-A: PMS COMPACT CORE version Part number A56-PMS-00-A: PMS COMPACT switchboard version with display RELATED PRODUCTS & CABLES i4GEN Touchscreen color display - Ref A56Vxx MASTER COMPACT Ref A56-MAST I/O Expansion - Ref LC5100 + KL1488 + KL2408 ... PC Connection Ethernet cable - Ref A53W1 CAN bus J1939/CRE/CAN open communication cable - Ref A40xx CRE TECHNOLOGY - 130, allee Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE Phone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - i

Open the catalog to page 1
COMPACT RANGE - 2

APPLICATIONS The COMPACT RANGE is well-suited for any PLC controlled systems interfacing with configurable binary and analog I/Os, or Modbus TCP communication; and a perfect controller to upgrade any existing single genset having a local control panel, into a ready to synchronize generator. The COMPACT RANGE is provided with all options included as standard and divided in 3 references to be more accurately adapted to your application: • SYNCHRO COMPACT is a synchronizing unit with dead bus bar management working in both manual and automatic mode. • ILS COMPACT is an automatic load sharing...

Open the catalog to page 2
COMPACT RANGE - 3

ISOLATED ISOLATED RELAY ETHERNET PORT I/O EXTENSION (32 DI/32 DO) J1939 PC CONNECTION MODBUS TCP REMOTE MONITORING CRE TECHNOLOGY - 130, allee Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE Phone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com - info@cretechnology.com COMPACT RANGE_SALES DOCUMENTATION_EN_B2018

Open the catalog to page 3

All CRE TECHNOLOGY catalogs and technical brochures

  1. I4GEN suite

    2 Pages

  2. I4GEN.10

    2 Pages

  3. ICGEN2.0

    55 Pages

  4. SCR 2.0

    19 Pages

  5. C2S

    16 Pages

  6. BP range

    2 Pages

  7. i4GEN

    2 Pages

  8. avrcompact

    2 Pages

  9. Synchro Compact

    144 Pages