video corpo

BTB COMPACT SALES DOCUMENTATION
4Pages

{{requestButtons}}

Catalog excerpts

BTB COMPACT SALES DOCUMENTATION - 1

BTB COMPACT Controller for bus tie-breaker applications BTB COMPACT is a new controller made to manage bus tie-breaker applications up to 32 bus tie-breaker. It operates in combination with GENSYS COMPACT PRIME (for generators) and MASTER COMPACT/MASTER COMPACT 1B (for mains) modules. It offers flexibility and time saving thanks to its simple wiring, all features included (no option), and easy programming. HARDWARE AND DISPLAY The BTB COMPACT is available in both switchboard panel mounted version with display, or core base mounted version and compatible with i4GEN touchscreen color display. SOFTWARE CORE BASE MOUNTED VERSION The BTB COMPACT is configurable from its front panel display, from i4GEN, or through the free CRE PC software. SWITCHBOARD MOUNTED VERSION WITH DISPLAY FEATURES CONTROL AND MANAGEMENT • Electrical parameters acquisition from wiring (PT) and from CANbus (KW, KVAR) of GENSYS COMPACT PRIME and MASTER COMPACT. • Synchronization: Frequency, Phase and Voltage synchronization from Source A to Source B or from Source B to Source A (Synchro scope display available on screen). Synch check (ANSI 25) + Phase sequence protection. • Adjustable KW ramp and KVAR ramp after synchronization. The 2 ramps are independents and allow managing properly the active and reactive power equalization if KW/KVAR ratio are different on source A and source B before tie-breaker closure. • Optimized frequency/KW and Voltage/KVAR regulation which does not require PID adjustment in the BTB COMPACT (except for the phase synchronization). The PID control is managed by each generator with GENSYS COMPACT PRIME. • Automatic detection of mains paralleling on source A or source B. Synchronization from mains to generators will be detected and not allowed. Only synchronization from generators to generators and from generators to mains will be allowed. • 2 password levels. • Automatic management of CANbus inhibitions according with tie-breaker closed or opened • Automatic clock synchronization by CANbus. DISPLAYED INFORMATIONS • Source A electrical parameters: • Voltage (3 phases RMS, L-L and L-N) • Frequency • Active and reactive power (from CANbus) • Power factor (from CANbus) • Source B electrical parameters: • Voltage (3 phases RMS, L-L and L-N) • Frequency • Active and reactive power (from CANbus) • Power factor (3 phases + total) (from CANbus) • Synchro scope and Synch check relay authorization values. • Log of alarms/faults with timestamp and real-time value. • Configurable event logger and info pages. AUTOMATIC FIRMWARE UPDATE: EVENTS LOGGER • All data are accessible by Modbus TCP locally or remotely (web, GPRS). • Read and write functions + 300 free Modbus TCP addresses available for custom mapping. • 1350 logged events with timestamp and real-time value are available on a non volatile memory. • The last 30 logged alarms/faults and 15 active alarms/ faults are available on front panel display. When module is connected to CRE PC software, you will automatically be asked for a firmware update to the latest version if applicable. MODBUS TCP SLAVE COMMUNICATION PORT ELECTRICAL PROTECTIONS: • Source A electrical protections: • F: ANSI Code 81L, 81H • U, U unbalance: ANSI Code 27, 59, 47 • Source B electrical protections: • F: ANSI Code 81L, 81H • U, U unbalance: ANSI Code 27, 59, 47 BREAKERS CONTROL • Adjustable pulses or latched contact for breaker closing. • Adjustable pulses or latched contact for breaker opening. • MN/MX coil management. PROGRAMMING FEATURES •Alternative selection: up to 16 parameters values can be modified by triggering any digital input or Modbus TCP variable. • Scheduler: Specific functions or modes (ex: auto start, test mode Boost…) can be programmed on scheduled operation (cyclic or one-time). • Easy Flex®: • 50 lines of programming with logic and arithmetic operators and conditions. • All inputs/outputs and variables available. • Generic filling feature: • High and low set point from digital or analog input. • Up or down direction configurable. Part numbers: A56-BTB-10-A Core base mounted version A56-BTB-00-A Switchboard mounted version with display RELATED PRODUCTS AND CABLES i4GEN Touchscreen color display – Ref A56Vxx GENSYS COMPACT PRIME – Ref A56-PRIME MASTER COMPACT– Ref A56-MAST MASTER COMPACT 1B – Ref A56-MAS1B Additional I/O – Ref LC5100 + KL1488 + KL2408 … PC Connection Ethernet cable – Ref A53W1 CRE/CANopen communication cable – Ref A40xx CRE TECHNOLOGY - 130, allée Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE Phone :

Open the catalog to page 1
BTB COMPACT SALES DOCUMENTATION - 2

BTB COMPACT associated with GENSYS COMPACT PRIME and MASTER COMPACT allows full automatic operation with the best easy way of the market: • 32 modules BTB COMPACT and MASTER COMPACT + 32 modules GENSYS COMPACT PRIME limited to 40 modules in total could be used together on the same application. • The complete power plant is divided in segments. A segment is a group of MASTER COMPACT and GENSYS COMPACT PRIME module which will always communicate each other. Each BTB COMPACT has a different segment on source A side and on source B side. • When the tie-breaker is opened, modules of...

Open the catalog to page 2
BTB COMPACT SALES DOCUMENTATION - 3

BTB COMPACT Controller for bus tie-breaker applications SPECIFICATIONS ELECTRICAL SYSTEM Compatible with 3 or 4 wires three-phase, or two-phase or single phase systems. VOLTAGE AND FREQUENCY • DC Power supply: 7...38VDC, Max voltage 45VDC during 15mn, current consumption at 24VDC = 130mA + the sum of maximum consumption of each logic output. • AC Voltage inputs: 80...500VAC. Consumption = 100mA max. Accuracy: 1%. 3ph + N for Source A / 3ph + N for Source B. Neutral terminal does not need to be connected. • AC Frequency measurement: 35...75Hz; 15VAC minimum between phase and neutral INPUTS,...

Open the catalog to page 3

All CRE TECHNOLOGY catalogs and technical brochures

  1. I4GEN suite

    2 Pages

  2. I4GEN.10

    2 Pages

  3. ICGEN2.0

    55 Pages

  4. SCR 2.0

    19 Pages

  5. C2S

    16 Pages

  6. BP range

    2 Pages

  7. i4GEN

    2 Pages

  8. avrcompact

    2 Pages

  9. Synchro Compact

    144 Pages