AMF COMPACT SALES DOCUMENTATION - 1

The AMF COMPACT is dedicated to a large variety of standby diesel or gas gensets, offering an automatic management of transfer switch on mains failure, as well as monitoring, control and protection of engine, alternator and power bus bars. AMF COMPACT range offers flexibility and time saving thanks to its simple wiring, all features included (no option), and easy engineering & programming. HARDWARE & DISPLAY AMF COMPACT is available in both switchboard panel mounted version with display, or core base mounted version. AMF COMPACT is also compatible with i4GEN touchscreen color display. AMF COMPACT range is configurable from its front panel display, remote touchscreen, or through our free PC software. CORE BASE MOUNTED VERSION SWITCHBOARD MOUNTED VERSION WITH DISPLAY FEATURES CONTROL AND MANAGEMENT • Complete engine control of diesel, gasoline or gas gensets (preheating, pre-glow, ignition, start/stop.. • Alternative or consecutive multiple starter management. • Warmup & Cool down at idle or nominal speed. • Remote start and test mode available ON/OFF load. • Compatible with all J1939 electronic engines. • Mains failure detection and changeover with adjustable load transfer time. • Override mode (protections inhibition + dedicated hour meter) following NFE 37-312 certification. • Non-essential load control on overload. • Battery Boost management. • Configurable maintenance cycle. • 2 password levels. DISPLAYED INFORMATIONS • Engine parameters: oil pressure, coolant temperature, speed, running hours meters (override & safe conditions), number of start attempts, battery voltage. and all J1939 values available on ECUs. • Generator electrical parameters: • Voltage (3 phases RMS, L-L & L-N) • Current (3 phases RMS) • Frequency • Active power (3 phases + total) • Reactive power (3 phases + total) • Power factor (3 phases + total) • Calculated active energy (kWh) • Calculated reactive energy (kWARh) • Mains electrical parameters: • Voltage (3 phases RMS, L-L & L-N) • Frequency • Current (1 phase RMS) • Active & reactive power • Power factor • Log of fault & alarms with timestamp & real-time value. • Configurable event logger and info pages. ELECTRICAL PROTECTIONS • Generator electrical protections: • <F, >F : ANSI Code 81L, 81H • <U, >U : ANSI Code 27, 59 • >I, >>I, >In, Ig : ANSI Code 50, 51,50N, 51G • <KW, >KW : ANSI Code 37P, 32P • <KVAR, >KVAR : ANSI Code 37Q, 32Q • Mains electrical protections: • <F, >F : ANSI Code 81L, 81H • <U, >U : ANSI Code 27, 59 • <KW, >KW : ANSI Code 37P, 32P • <KVAR, >KVAR : ANSI Code 37Q, 32Q BREAKERS CONTROL • Adjustable Pulses or latched contact for breaker closing. • Adjustable Pulses or latched contact for breaker opening. • MN/MX coil management. EVENTS LOGGER • 1350 logged fault & alarms with timestamp & real-time value, on a nonvolatile memory. • Configurable event logger and info page. • The last 30 logged alarms/faults & 15 active alarms/ faults are available on front panel display. PROGRAMMING FEATURES • Alternative selection: up to 16 parameters values can be modified by triggering any digital input or Modbus variable. • Scheduler: specific functions or modes (ex: auto start, test MODE, Boost.) can be programmed on scheduled operation (cyclic or one-time). • Easyflex: • 50 lines of programming with Logic & Arithmetic operators and conditions. • All inputs/outputs and variables available. • Generic filling feature: • High and low set point from digital or analog input. • Up or down direction configurable. AUTOMATIC FIRMWARE UPDATE When module is connected to CRE PC software, you will automatically be asked for a firmware update to the latest version if applicable. MODBUS TCP SLAVE COMMUNICATION PORT • All data are accessible by Modbus TCP locally or remotely (web, GPRS). • Read and write functions on 300 free Modbus address available for custom mapping. REMOTE SUPERVISION WITH BSD 2.0 MODULE (CLOUD TECHNOLOGY) • Geolocalisation: you can see from your PC or smartphone the localization of your complete gensets fleet. • Geo Fencing: In case of genset moving beyond a configurable limit, you will be informed by message. • Monitoring and control of the genset. • Alert messages (SMS, emails). • Up to 8 users access levels. • Free Cloud license. Part number: A56-AMF-10-A CORE base mounted version Part number: A56-AMF-00-A Switchboard mounted version with display RELATED PRODUCTS & CABLES i4GEN Touchscreen color display - Ref A56Vxx I/O Expansion - Ref LC5100 + KL1488 + KL2408 ... PC Connection Ethernet cable - Ref A53W1 CAN bus J1939/CRE/CAN open communication cable -RefA40xx Remote monitoring system BSD2.0 - Ref A61Y1 CRE TECHNOLOGY - 130, allee Charles-Victor Naudin - Zone des Templiers - SOPHIA ANTIPOLIS - 06410 BIOT - FRANCE Phone : + 33 (0)4 .92.38.86.82 - www.cretechnology.com -

Open the catalog to page 1
AMF COMPACT SALES DOCUMENTATION - 2

APPLICATIONS AMF COMPACT is an Automatic Mains Failure unit, ensuring a complete management of standby genset in backup of mains supply, by continuously monitoring utility input and starting the genset in case of operator request or emergency. AMF Compact allow user control, test operation on schedule or from switchboard. Its flexibility provides a large capability of features usable on the controller inputs / outputs or the 32 I/O expansions that can be connected on CAN bus. A Modbus TCP access is available on the Ethernet port, also used for PC connection. STANDBY GENSET WITH MAINS IN...

Open the catalog to page 2
AMF COMPACT SALES DOCUMENTATION - 3

AMF COMPACT Enhanced Auto Mains Failure genset controller SPECIFICATIONS ELECTRICAL SYSTEM Compatible with 3 or 4 wires tri-phase, or bi-phase or single phase systems. • 2 x Relay Outputs (breaker control): 5A, 240VAC. • Magnetic pick up input: Frequency from 50 to 10 kHz, Voltage from 0,5VAC to 40 VAC. CURRENT, VOLTAGE AND FREQUENCY COMMUNICATION PORTS 3 x isolated com ports are available: • 1 CAN bus: J1939 electronic engine and I/O extensions. • 1 CAN bus available. • 1 Ethernet: PC communication/ Modbus TCP. INPUTS, OUTPUTS • 9 x Binary Inputs: NO or NC to ground. Adjustable timer ON...

Open the catalog to page 3

All CRE TECHNOLOGY catalogs and technical brochures

  1. I4GEN suite

    2 Pages

  2. I4GEN.10

    2 Pages

  3. ICGEN2.0

    55 Pages

  4. SCR 2.0

    19 Pages

  5. C2S

    16 Pages

  6. BP range

    2 Pages

  7. i4GEN

    2 Pages

  8. avrcompact

    2 Pages

  9. Synchro Compact

    144 Pages