Schlegel Contact Blocks
5Pages

{{requestButtons}}

Catalog excerpts

Schlegel Contact Blocks - 1

Storage Temperature -50 > C up to +85 > C Operating Temperature -30 > C up to +85 > C For non-illuminated items -30 > C up to +55 > C Using incandescent lamps -30 > C up to +65 > C Using LEDҒsOperating Travel approx. 6mm Protection Class II Connections screw connections for 2 x 2.5mm > 2 , fi nger protected.Lamp Type/Socket incandescent lamps, LEDs / BA9s Contact Material silver-nickel alloy (Ag/Ni) Mechanical Life 1 million operations Electrical Life 1 million cycles at rated load Min. Current / Voltage 1 mA / 5V (Under laboratory conditions) Contact Resistance (New State) < 20mҢĦ Bounce Time < 9 mS Positive Opening N/C Contact to EN 60947-5-1 appendix K > Utilisation Category AC15 A600 DC13 Q600 Rated Insulation Voltage (Ui) 600V 600V Rated Operational Voltage (Ue) 250V (3A) 440V (0.12A), 250V (0.2A) [Rated Operational Current (Ie)] 440V (1.6A) 125V (0.4A), 60V (1A), 24V (2A) Breaking Capacity 10Ie 1.1Ie Continuous thermal current (Ith) 16A 16A Gold Plated Version available upon request > Lamp Socket BA9sLamp Voltage max. 250V (CSA max. 125V)Lamp Output max. 2WDefi nition X1.. anode, X2.. cathode. > ImageContact DetailsDescriptionCatalogue No Modular Contact Block, Momentary MTOModular Contact Block, Momentary N/C MTI N/O page 1 of 5 > Hall Lane, Walsall Wood, Walsall, West Midlands WS9 9DPt: +44(0)1543 375541 f: +44(0)1543 361619 e: sales@craigandderricott.com

Open the catalog to page 1
Schlegel Contact Blocks - 2

ImageContact DetailsDescriptionCatalogue No MTZModular Contact Block, Momentary, for Emergency Stop Actuators. Modular Contact Block, Momentary, with permissive function. 2 stage. N/O > N/C < N/O MTOSLatching Module MF 1 N/C safety contact switching off in an emergency and 1 N/C series contact that opens should the contact block become detached from the actuator. when used as the centre element in the module holder, it provides a maintained unit with the adjacent momen- tary type modules. > x1x2 Lamp Module BA9s MLLatching Module - BA9s max. 250V 2W MFL when used as the centre element in...

Open the catalog to page 2
Schlegel Contact Blocks - 3

Storage Temperature -50 > C up to +70 > C Operating Temperature -30 > C up to +70 > C For non-illuminated items -30 > C up to +70 > C Using incandescent lamps -30 > C up to +70 > C Using LEDsOperating Travel approx. 6mm Protection Class II Connections screw connections for 2 x 2.5mm > 2 , fi nger protected.Lamp Type/Socket incandescent lamps, LEDҒs / BA9s Contact Material silver-nickel alloy (Ag/Ni) Mechanical Life 1 million operations Electrical Life 1 million cycles at rated load Min. Current / Voltage 1 mA / 5V (Under laboratory conditions) Contact Resistance (New State) < 20mΩ Bounce...

Open the catalog to page 3
Schlegel Contact Blocks - 4

C up to +70 > C For non-illuminated items -30 > C up to +55 > C Using incandescent lampsProtection Class IIConnections Faston terminals 2.8 x 0.8mmLamp Type/Socket T5, 5K Contact Material silver-nickel alloy (Ag/Ni) - gold plated versions available Bouncing Time (AT..., AF..., AZ...) < 10mS (AT2) < 27mSPositive Opening N/C Contact to EN 60947-5-1 appendix K > Utilisation Category AC15 A300 DC13 Q300 Rated Insulation Voltage (Ui) 250V 300V Rated Operational Voltage (Ue) 250V 250V (0.2A), 125V (0.4A), 60V (1A), 24V (2A) [Rated Operational Current (Ie)] 125V (0.4A), 60V (1A), 24V (2A) Breaking...

Open the catalog to page 4