Catalog excerpts
isolation equipment Trent Range Օ Classic Range > make the switch size="-1">
Open the catalog to page 1As well as our existing Classic ђ and Stenton ђ ranges, we nowoffer our new family of switch disconnectors. The new Trent ђrange of isolators, changeovers and fuse combination units is the most extensive ever offered by Craig and Derricott, and the largest offered by any European Manufacturer. Consistent design features throughout the complete range providesseamless product integration, which is non function dependent. Ranging from 25A to 1000A and available in various enclosure materials and colours. Selecting an isolation solution from Craig &Derricott combines excellent performance,...
Open the catalog to page 2isolation equipment Rating (A) ApplicationSym.UnitCategory25A40A63A Rated thermal current I > the A254063 Rated insulation voltage U > i V690690690 Rated impulse voltage U > imp kV4.04.04.0400/415V - AC21A25.040.063.0 Rated operational current (AC) A400/415V - AC22A25.040.063.0400/415V - AC23A25.040.063.0 Rated operational power (AC) kW3 x 400V - AC2310.018.522.0 Conditional short circuit current I > cc kA6.06.08.0 Minimum mechanical endurance Cycles0.3 x 10 > 6 0.3 x 10 > 6 0.3 x 10 > 6 -Terminal typemm Connecting capacity > 2 Flexible cable2.5 - 6.010 - 1616 - 50mm > 2 Stranded cable2.5 -...
Open the catalog to page 6isolation equipment Rating (A) ApplicationSym.UnitCategory25A40A63A Rated thermal current I > the A254063 Rated insulation voltage U > i V690690690 Rated impulse voltage U > imp kV4.04.04.0400/415V - AC21A25.040.063.0 Rated operational current (AC) A400/415V - AC22A25.040.063.0400/415V - AC23A25.040.063.0 Rated operational power (AC) kW3 x 400V - AC2310.018.522.0 Conditional short circuit current I > cc kA6.06.08.0 Minimum mechanical endurance Cycles0.3 x 10 > 6 0.3 x 10 > 6 0.3 x 10 > 6 -Terminal typemm Connecting capacity > 2 Flexible cable2.5 - 6.010 - 1616 - 50mm > 2 Stranded cable2.5 -...
Open the catalog to page 8isolation equipment (Applicable to all finishes and materials) All dimensions in mm case sizes > Dim EDim CDim HDim A Material: Stainless steel grade 304 Cat Ref: EFL/KIT (Set of four feet)The external feet can be attached for verticalor horizontal fixings (as shown). > ؘ6.530 Internal mounting hole Dim D > Cabinet Locks > TRENT All metal locks supplied with one key per enclosure.Enclosure Sizes 1 & 21 LockEnclosure Sizes 2A, 3, 4 & 52 LocksEnclosure Size 63 Locks Material: ThicknessGradeSheet steel:Sizes 1, 2 & 2A1.2-Sizes 3, 4 & 51.5 - Size 62.0-Stainless steel:Sizes 1 - 51.5304Size...
Open the catalog to page 13isolation equipment Material: Stainless steel grade 304 Cat Ref: EFS/KIT (Set of four feet) Internalmounting hole > Hall Lane, Walsall Wood, Walsall, West Midlands WS9 9DP >
Open the catalog to page 16isolation equipment From July 2006, the onus was placed upon companies to ensure that all equipment within their organisations is suitable for theenvironment in which it is being used.This was aimed particularly at areas where there may be a possibility of a combustible atmosphere being present, even for short periods. i.e. less than 10 hours/year.People normally think of such atmospheres as being gases, mists or vapours, however there are various industries where a conductive, or non conductive dust mixed with air in the right proportion, can become explosive. It is these areas where the...
Open the catalog to page 17isolation equipment 4 x M8 Fixing Lugs(supplied loose) > ▲ SizeHLPBCD >
Open the catalog to page 19isolation equipment From July 2006, the onus was placed upon companies to ensure that all equipment within their organisations is suitable for theenvironment in which it is being used.This was aimed particularly at areas where there may be a possibility of a combustible atmosphere being present, even for shortperiods. i.e. less than 10 hours/year.People normally think of such atmospheres as being gases, mists or vapours, however there are various industries where a conductive, or non conductive dust mixed with air in the right proportion, can become explosive. It is these areas where the...
Open the catalog to page 20isolation equipment 4 Mounting Holes 8.3 Dim ADim HDim EDim C Dim B Dim F Dim D 2.3 Dim W External mounting feet kit is available for this item. Please contact our sales department for details. Dim HWDABCEF (mm)2702851302002152558188 > MaterialFinishEntries Sheet steel thickness 1.2 mmIron Phosphate pre treatment + Powder3mm thick removable gland plate on coat RAL 3020 (Traffic Red) textured finishbottom facer TRENT BS EN 50014, BS EN 50281-1-1, BS EN 60529 BS EN 60947-3, BS EN 60204-1 (Must not be used in areas which exhibit conductive dust.) > Hall Lane, Walsall Wood, Walsall, West...
Open the catalog to page 22Fire Rated - (High Temperature)Isolators (20A-125A) isolation equipment Enclosure Dimensions A > *Handle projection:- 30mm B C > CLASSIC D > RANGE still need more? isolationequipment craigandderricott.com > 23 size="-1">
Open the catalog to page 25isolation equipment Side view of enclosure showing the contoured lid which ensures easy access to the isolating switch terminals > Typical interior assembly showing ґplug-in interior isolating switch and earth and neutral continuity terminals > CLASSIC STENTON Auxiliary Contacts The ґEB addition to the catalogue numbers denotes the inclusion of 2 off early break contacts.In all cases these are factory fitted tothe isolator interior, and are not available as a customer addition.All auxiliary contacts are fully rated and are designed to open before the maincontacts when switching ґOff.By...
Open the catalog to page 28The new Craig & Derricott Craig and Derricott is now morethan 62 years new; with new products, new lean manufacturing, new systems, and ambitious service levels. We have witnessed a huge turnaround in customer satisfaction, by providing a unique level of customer service and support.You the customer are our lifeblood.Many of our customers have been placing regular orders with us for decades. Thank you!Performance, reliability, our bespokeproducts and classic designs are established product features, which have built the reputation which we hold today.However you cannot stand still, and...
Open the catalog to page 32All Craig & Derricott catalogs and technical brochures
-
Uk CATALOGUE 2021
108 Pages
-
PV Switch
4 Pages
-
FSDMR series
2 Pages
-
SDDG series
3 Pages
-
SDS series
2 Pages
-
i switch catalog
32 Pages
Archived catalogs
-
Classic Limit Switch Range
4 Pages
-
Grabwire Switches
7 Pages
-
Medium duty footswitches
4 Pages
-
Heavy duty footswitches
7 Pages
-
Classic Control Stations
5 Pages
-
Classic 32 Series components
5 Pages
-
Schlegel ‘Kombitast-R’ Range
3 Pages
-
Schlegel Contact Blocks
5 Pages
-
Schlegel ‘Quartron’ Range
3 Pages