Grabwire Switches - 2

Apart from the Grabwire switch, the only other item required in a simple set-up, is the connection kit. In the kit you will fi nd all the parts necessary to install the system. Each kit includes:- Multi strand steel catenary cable with red PVC covering * Օ Stainless steel eyebolt supports. Suffi cient to support the cable at 2M intervals. Supplied complete with two fi xing nuts.* 2 x Stainless steel thimbles. Օ 2 x Stainless steel Dђ shackles. 2 x Stainless steel clamps. DescriptionCatalogue Ref.DescriptionCatalogue Ref. Basic connection kit *Catenary wire and eyebolts not included GK0010M...

Open the catalog to page 2
Grabwire Switches - 4

Technical Data Sheet > Grabwire Switches > Dimensions GWDE Double Ended Grabwire Switch Page 4 Craig & Derricott Ltd Hall Lane, Walsall Wood, Walsall, West Midlands WS9 9DPt: +44(0)1543 375541 f: +44(0)1543 361619 e: sales@craigandderricott.com

Open the catalog to page 4
Grabwire Switches - 5

Designed specifi cally for long distance protection, where a tensioned wire installation (GW series) becomes expensive or impractical.Complying with the latest standards for safety installations, the Live Wire system incorporates the following safety features:- The trip switch interior to each grabwire assembly contains positive push-off contacts Օ The system will trip in the event of - (a) a Grab-Line being pulled in any direction. (b) a Grab-Line being broken or the Grab-Line circuit interrupted. (c) a short circuit condition occurring in the Grab-Line circuit. (d) a loss of power to the...

Open the catalog to page 5
Grabwire Switches - 6

The installed system must fall within the following parameters:-1 The total length of Grab-Line safety circuit will consist of - The feed from the CS1 Control Station to the fi rst Grab-Live switch Օ The Grab-Line run If connected, the two wire connection for conveyor interlock control The total of the above must not exceed 2000M or a total circuit resistance of 50 ohms.2 The distance between Grab-Line switches must not exceed 150M.3 The interconnections between Grab-Line switches is by the Grab-Line cable which must be secured to each of the Grab-Line switches by the attachments provided.4...

Open the catalog to page 6
Grabwire Switches - 7

Input Voltage 110V (15W max.), 240V (15W max) Control Station Assembly CS1 System Voltage 24V a.c. - 1/2 wave rectifi ed. LH Grab-Line switch LG1/L Control circuit relay Contact operation Positively operated Rated load 3A at 240V a.c. 3A (Resistive) at 24V d.c. Max. switching current 6A Max. switching Voltage 250V a.c. & 24V d.c. Minimum permissible load 5V d.c. - 10mA Mechanical/Electrical life 10 x 10 RH Grab-Line switch LG1/R Mid Grab-Line switch LG1/M Grab-Line cable (75M) GWC 0038A Grab-Line cable (100M) GWC 0038B Grab-Line cable (125M) GWC 0038C Grab-Line cable (150M) GWC 0038D St St...

Open the catalog to page 7