ASEPTIQUIK ® STC connectors
6Pages

{{requestButtons}}

Catalog excerpts

ASEPTIQUIK ® STC connectors - 1

Actual size AseptiQuik STC Connectors integrate the AseptiQuik® sterile connector and the Steam-Thru® II SIP connector, giving manufacturers even greater flexibility for hybrid stainless steel and single-use processing. The AseptiQuik STC connector combines either an AseptiQuik G or AseptiQuik C sterile connector with a Steam-Thru II connection that can be mounted directly to a stainless steel vessel via a sanitary termination. AseptiQuik STC connectors utilizing an AseptiQuik G sterile connector offer a genderless design, simplifying system integration at the aseptic connector end. AseptiQuik STC connectors utilizing an AseptiQuik C sterile connector allow system designers to incorporate a keyed female-to-male connection at the aseptic connector end. The union of the two connectors into a single unit through a sanitary clamp allows an AseptiQuik sterile connection to be steamed on to stainless equipment via SIP. After the SIP cycle, a wide range of single-use systems can be connected. The SIP process can be done in advance allowing a quick and easy sterile connection to the AseptiQuik half without having to wait 30-60 minutes for SIP prior to harvest. AseptiQuik STC Specifications Pressure: Steam position: Up to 35 psi, 2.4 bar Flow position: Up to 20 psi, 1.4 bar Temperature: Steam position: Up to 275°F (135°C) for 60 minutes Flow position: 39°F to 104°F (4°C to 40°C) Sterilization: Gamma: Up to 50kGy irradiation AutoClave: High Temp (HT) version: Up to 266°F (130°C) for 30 minutes (AQSTC) Up to 266°F (130°C) for 60 minutes (AQGSTC) Note: A slight clockwise rotation of the clamp nut may be needed after autoclave. Materials: Main Components: AseptiQuik - Polycarbonate (white), USP Class VI, ADCF Steam-Thru II - Polysulfone (amber tint), USP Class VI, ADCF Seals: Silicone (clear), platinum-cured, USP Class VI, ADCF Pull Tabs: Polycarbonate (blue, standard version), USP Class VI, ADCF Polycarbonate (white, HT version), USP Class VI, ADCF Caps: Polypropylene (clear), USP Class VI, ADCF AseptiQuik design Innovative three-step connection process reduces risk of operator error Genderless design Eases integration of single-use systems with universal mating between AseptiQuik G Connectors Innovative three-port steam design Allows a true steam-through SIP process which eliminates "dead legs" Robust construction Repeatable and reliable performance with no additional hardware required Patented steam valve design Allows sterile connection and disconnection to stainless equipment and permits a high media flow rate. Sanitary interface between the two connectors More secure connection than tubing with cable ties Colder Click Audible confirmation of assembly steps Market availability Open access through multiple supply chain partners Membrane: Polyethylene (standard version), USP Class VI, ADCF Hydrophobic polyethersulfone (HT versions), USP Class VI Clamp: Nylon 66 (white), USP Class VI

Open the catalog to page 1
ASEPTIQUIK ® STC connectors - 2

Height/Diameter Total Length Actuated Length Coupling Bodies Standard Version with Blue Pull Tabs TERMINATION 3/4" X 3/4" SANITARY STEAM-THRU II with AseptiQuik Body 3/4" X 1-1/2" SANITARY STEAM-THRU II with AseptiQuik Body (pictured) Note: Mates with any male AseptiQuik connector. Coupling Bodies ASEPTIQUIK STC CONNECTOR HT Version with White Pull Tabs TERMINATION 3/4” X 3/4” SANITARY STEAM-THRU II with AseptiQuik Body (pictured) 3/4” X 1-1/2” SANITARY STEAM-THRU II with AseptiQuik Body Note: Mates with any male AseptiQuik connector. CLICK–PULL–TWIST Assembly Procedure Steam flows from the...

Open the catalog to page 2
ASEPTIQUIK ® STC connectors - 3

Snap membrane pull tabs together and pull from connector. Twist the blue lock ring clockwise until audible “Colder Click.” Alignment of the lock ring rib with the body’s arrow indicator confirms final connection. Once the AseptiQuik assembly is complete and the steam trap has been closed, simply press the thumb latch to allow the valve to be pushed into the flow position. The “Colder Click” confirms the transition is complete. 7 Once the valve is locked into the flow position, you are ready for sterile fluid transfer to or from the process equipment. 8 After sterile media transfer is...

Open the catalog to page 3
ASEPTIQUIK ® STC connectors - 4

Height/Diameter Total Length Actuated Length Coupling Bodies Standard Version with Blue Pull Tabs TERMINATION 3/4" X 3/4" SANITARY STEAM-THRU II with genderless AseptiQuik G Body 3/4" X 1-1/2" SANITARY STEAM-THRU II with genderless AseptiQuik G Body Coupling Bodies Note: Mates with any AseptiQuik G Connector. HT Version with White Pull Tabs TERMINATION 3/4” X 3/4” SANITARY STEAM-THRU II with genderless AseptiQuik G Body 3/4” X 1-1/2” SANITARY STEAM-THRU II with genderless AseptiQuik G Body Note: Mates with any AseptiQuik G Connector. FLIP-CLICK-PULL Assembly Procedure Steam flows from the...

Open the catalog to page 4
ASEPTIQUIK ® STC connectors - 5

ASEPTIQUIK® G STC CONNECTOR (cont.) Pull the snapped-together membrane pull tabs from the connector. Remove the Steam-Thru II lock sleeve. Once the genderless AseptiQuik G assembly is complete and the steam trap has been closed, simply press the thumb latch to allow the valve to be pushed into the flow position. The “Colder Click” confirms the transition is complete. Once the valve is locked into the flow position, you are ready for sterile fluid transfer to or from the process equipment. 7 After sterile media transfer is complete, simply press the thumb latch and pull the valve back into...

Open the catalog to page 5
ASEPTIQUIK ® STC connectors - 6

COLDER PRODUCTS COMPANY Colder Products Company is the leader in the design and manufacture of single-use connection technology and connectors for the life sciences markets. Colder offers a wide variety of bioprocessing solutions including sterile connect, sterile disconnect, SIP connections and quick connects. Our innovative designs provide flexibility for biopharmaceutical manufacturers to easily combine multiple components, single-use or hybrid systems including process containers, tubing manifolds, transfer lines, bioreactors and other bioprocess equipment. Robust and easy-to-use...

Open the catalog to page 6