Catalog excerpts
Rotary vane vacuum pumps Applications The PVS series rotary vane vacuum pump, includes integrated suction filters in series. Their functioning is silent and vibration free. • Flow rate: 4.1m3/h (50 Hz) - 4.7 m3/h (60Hz) • Maximum vacuum : -150 mbar absolus • Available : 230/400 V Tri (1)mbar absolute (2)DIN EN ISO 3744 (KpA=3dB(A)) interval of 1m, at medium mload, both connection sides piped VI (V2) Vacuum connection V3 (V4) Vacuum regulating valve P3 (P4) Blow-off valve (xx) Alternatif (3~) PVS4T3 Note: All dimensions are in mm , COVAL vacuum managers
Open the catalog to page 1Rotary vane vacuum pumps Suction air rate Exhaust air temperature 0 100 Motor shaft power -40 -60 Reference data (atmosphere) Tolerance www.coval.com - Technical data PVS 4 -
Open the catalog to page 2Rotary vane vacuum pumps Applications The PVS series rotary vane vacuum pump, includes integrated suction filters in series. Their functioning is silent and vibration free. • Flow rate : 8m3/h (50Hz) - 9.1m3/h (60 Hz) • Maximu vacuum : -150 mbar (absolute) • Avaliable : o 230 V Mono o 230/400 V Tri PVS8M1: Single phase (1~) PVS8T3: Three-phase version (3~) (1)mbar absolute (2)DIN EN ISO 3744 (KpA=3dB(A)) interval of 1m, at medium mload, both connection sides piped VI (V2) Vacuum connection V3 (V4) Vacuum regulating valve P3 (P4) Blow-off valve (xx) Alternatif (1 ~) PVS8M1 (3~) PVS8T3 Note:...
Open the catalog to page 3Rotary vane vacuum pumps Motor shaft power 0 100 Reference data (atmosphere) Tolerance
Open the catalog to page 4Rotary vane vacuum pumps Applications The PVS series rotary vane vacuum pump, includes integrated suction filters in series. Their functioning is silent and vibration free. • Flow rate : 10m3/h (50 Hz) - 12m3/h (60 Hz) • Maximum vacuum :-150 mbar (absolute) • Available : o 230 V Mono o 230/400 V Tri PVS10M1 Single phase version (1~) PVS10T3 Three-phase version (3~) (1)mbar absolute (2)DIN EN ISO 3744 (KpA=3dB(A)) interval of 1m, at medium mload, both connection sides piped VI (V2) Vacuum connection V3 (V4) Vacuum regulating valve P3 (P4) Blow-off valve 'V (xx) Alternatif (1 ~) PVS10M1 (3~)...
Open the catalog to page 5Rotary vane vacuum pumps Reference data (atmosphere) Tolerance COYAL vacuum managers
Open the catalog to page 6Rotary vane vacuum pumps Applications The PVS series rotary vane vacuum pump, includes integrated suction filters in series. Their functioning is silent and vibration free. • Flow rate: 16m3/h (50 Hz) - 19 m3/h (60 Hz) • Maximum vacuum : -150 mbar absolus • Available: o 230 V Mono o 230/400 V Tri Models PVS16M1: Single phase version (1~) PVS16T3 : Three-phase version (3~) (1)mbar absolute (2)DIN EN ISO 3744 (KpA=3dB(A)) interval of 1m, at medium mload, both connection sides piped VI (V2) Vacuum connection V3 (V4) Vacuum regulating valve P3 (P4) Blow-off valve (xx) Alternatif „ COVAL vacuum...
Open the catalog to page 7Rotary vane vacuum pumps Debit d’air Aspire -40 -60 Reference data (atmosphere) Tolerance www.coval.com - Technical data PVS 16 - COYAL _ vacuum managers
Open the catalog to page 8Rotary vane vacuum pumps Applications The PVS series rotary vane vacuum pump, includes integrated suction filters in series. Their functioning is silent and vibration free. • Flow rate : 25m3/h (50 Hz) - 30m3/h (60 Hz) • Maximum vacuum : -150 mbar absolus • Available: o 230 V Mono o 230/400 V Tri PVS10M1: Single phase version (1~) PVS10T3: Three-phase version (3~) (1)mbar absolute (2)DIN EN ISO 3744 (KpA=3dB(A)) interval of 1m, at medium mload, both connection sides piped VI (V2) Vacuum connection V3 (V4) Vacuum regulating valve P3 (P4) Blow-off valve (xx) Alternatif (1 ~) PVS25M1 (3~)...
Open the catalog to page 9Rotary vane vacuum pumps Suction air rate Exhaust air temperature -20 -40 -60 Motor shaft power -40 60 Reference data (atmosphere) Tolerance ^ COVAL vacuum managers
Open the catalog to page 10Rotary vane vacuum pumps Applications The PVS series rotary vane vacuum pump, includes integrated suction filters in series. Their functioning is silent and vibration free. • Flow rate: 40m3/h (50 Hz) - 48m3/h (60 Hz) • Maximum vacuum: -150 mbar absolus • Available: o 230 V Mono o 230/400 V Tri PVS40M1 Single phase version (1~) PVS40T3 Three-phase version (3~) (1)mbar absolute (2)DIN EN ISO 3744 (KpA=3dB(A)) interval of 1m, at medium mload, both connection sides piped VI (V2) Vacuum connection V3 (V4) Vacuum regulating valve P3 (P4) Blow-off valve (xx) Alternatif JCOVAL vacuum managers
Open the catalog to page 11Rotary vane vacuum pumps Suction air rate Motor shaft power Reference data (atmosphere) Tolerance ^ COVAL vacuum managers
Open the catalog to page 12Rotary vane vacuum pumps Applications The PVS series rotary vane vacuum pump, includes integrated suction filters in series. Their functioning is silent and vibration free. • Flow rate : 98 m3/h (50 Hz) - 112 m3/h (60 Hz) • Maximum vacuum: -100 mbar absolus • Available: 230/400 V Tri (1)mbar absolute (2)DIN EN ISO 3744 (KpA=3dB(A)) interval of 1m, at medium mload, both connection sides piped , COVAL vacuum managers
Open the catalog to page 13Rotary vane Vacuum pumps Reference data (atmosphere) Tolerance „ COVAL vacuum managers
Open the catalog to page 14All COVAL catalogs and technical brochures
-
GLOBAL CATALOG Uk
388 Pages
-
GLOBAL CATALOG US
388 Pages
-
GLOBAL CATALOG UK-CH
388 Pages
-
Interactive Catalog
1 Pages
-
CVGL
20 Pages
-
ADVANCED VACUUM SOLUTIONS
16 Pages
-
In-line ejectors, CIL
2 Pages
-
Vacuum switch PSK Series
1 Pages
-
Mini Vacuum Filters, FVG
1 Pages
-
Products Range Coval
6 Pages
-
REV 38 Vacuum Regulator
1 Pages
-
RVM, RVF, RVT, TVR, COV
1 Pages
-
Silencer SILGV - SILK
1 Pages
-
Vacuum Filters, FVI
2 Pages