video corpo cad

MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES
12Pages

{{requestButtons}}

Catalog excerpts

MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES - 1

series LEMCOM Mini Vacuum Pumps with Fieldbus Communication

Open the catalog to page 1
MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES - 2

LEMCOM Series: 1st Mini Vacuum Pump pressure In a world where everything is connected, COVAL is innovating once more by unveiling the LEMCOM series: the first vacuum pump on fieldbus. Compact integration: The COVAL technique The illustrations demonstrate the COVAL advantage: all necessary functions are integrated into a complete and self-governing mini-module, INTEGRATED FUNCTIONS ➊ 3.5 bar pressure regulator ➋ "Vacuum" solenoid valve ➌ 3.5 bar optimized venturi ➍ Optimized silencer ➎ Vacuum non-return valve ➏ Vacuum sensor ➐ Integrated electronics: management Schematic representation of...

Open the catalog to page 2
MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES - 3

on Industrial Fieldbus 2 vacuum levels to match precise application needs Suction flow rate (Nl/min) : • Air Saving Regulator 40 % of energy savings on average. ■ Air Saving Control 90 % of energy savings on average. 2 integrated energy-saving technologies 40 % energy savings (on average, see p.4). Combination of non-return valve © and advanced electronics © ensures ASC's automatic performance. Once vacuum is established, the pump no longer consumes air to hold the product. LEMCOM series vacuum pumps, which integrate an ASR “venturi regulator” combination, maintain ideals that COVAL values...

Open the catalog to page 3
MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES - 4

Energy saving & intelligence (ASC): airtight products vacuum Venturi max. vacuum L2* "ASC" threshold L1* “Product Gripped” signal threshold Vacuum generation stop Blow-off command signal “Product Gripped” signal authorises operation (1.4 mm nozzle Ø, emptying 0.2 l). Air consumption Duration without 2Operations on Vacuum Gripped Product Gripping 0.28 s 0.4 Nl Transfer 1.20 s 1.8 Nl Release 0.14 s 0.2 Nl Vacuum automatica resumed lly energy savings achieved Vacuum command signal Consumed air * L1 and L2 are the values of adjustable thresholds 0 vacuum time Zero consumption Duration without...

Open the catalog to page 4
MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES - 5

Individual or island modules? Stand-alone modules are suitable for the most common applications: one module controls one or more suction cups, all of which operate according to the same sequence. When several suction cups are operating according to different sequences, multiple modules are required, which can be: several autonomous modules, OR a group of these modules with an internally shared pressure supply The illustrations shown here guide the selection: autonomous modules are coupled with integrated pressure regulators (ASR) in a group, the integrated regulator is eliminated: to...

Open the catalog to page 5
MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES - 6

Series: simplified ammaa SmSSF Ethen 'et/IP CflNopon Multitude of Innovations ■ Maximum intelligence / minimal bulk. ■ One "master" module controls up to 15 secondary modules. ■ Master module is a fully-integrated pump. ■ Remote configuration, monitoring and diagnostics. ■ Dedicated Coval bus between master and secondary modules. ■ Simplified wiring and installation. ■ Standard secondary modules (regardless of the type of bus). ■ Additional communications port. ■ Supported buses: EtherNet/IP™ / Profinet / CANopen®... ■ IP65 / M8 standard connectors. A simple product to utilize LEMCOM master...

Open the catalog to page 6
MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES - 7

communication for all processes A setting for every application The LEMCOM is based on an innovative, efficient product structure: The "master" module manages communication on the fieldbus, assures management of the "secondary" modules and is a fully-integrated vacuum pump. Its 2 communication ports enable a continuous fieldbus. The "secondary" modules are interconnected with the "master" module via the COVAL bus. Contact between the "master" module and the "secondary" modules is confirmed by an M8 connecting bridge for island configurations or by a M8/M8 standard cable for configurations...

Open the catalog to page 7
MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES - 8

VACUUM LEVEL VENTURI SPECIFICATIONS: 1- Maximum Vacuum Level Dependent upon the mixer profile: - 85% of maximum vacuum is optimal for gripping airtight products. - 60% of maximum vacuum is optimal for gripping porous products. 2- Nozzle Diameter Reflects the generated vacuum flow rate, as well as energy consumption. Hence, it must be selected to meet precise requirements without wasting energy. NOZZLE DIAMETER MODULE COMPOSITION 10 NC Vacuum pump with blow-off LEMC__X__S__G__ NC vacuum control valve: in case of electrical cut-off, vacuum generation stops (see p. 5). Blow-off configured on...

Open the catalog to page 8
MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES - 9

aosan master LEMC X___Q2G__ ■ On-board 2-Port Ethernet Switch. ■ On-board web server. ■ Dedicated configuration software. ■ M8/RJ45 standard connectors. Island assemblies W2 CflNopoQ master LEMC X W2G ■ Two CAN ports. ■ From 20 to 1000 Kbps. ■ Dedicated configuration software. ■ Configuration by SDO. ■ Regulated PDO-TX transmission threshold. Island assembly with 2 modules, with connecting bridges for internal "COVAL Bus" and M8/M8 120 Q termination: The first module is of the type selected B3 The following one is a secondary module. LEMC__XGB3 ■ On-board 2-Port Ethernet Switch. ■ On-board...

Open the catalog to page 9
MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES - 10

Dimensions, mounting options 1- Stand-alone modules Mounting from side 12.5 Connector hole pitch ("master" module) 2 connecting screws or bolts, Ø 4mm Mounting from front individual mounting plate with 4 mounting screws To mount from front, in addition to the module, a mounting kit must be ordered: Kit for mounting from front: 1 plate + 4 screws Individual mounting plate with DIN mounting clip and 4 mounting screws For static mounting (for example, in a cabinet), a module can be clipped onto a DIN rail. For this purpose, the module must first be equipped with an individual plate for...

Open the catalog to page 10
MINI-VACUUM PUMP WITH FIELDBUS COMMUNICATION, LEMCOM SERIES - 11

Electrical connectionsLEMCOM master Ether* 'et/IP LEMCOM secondary module 0@0 24V CC CAN-H CAN-GND CAN-L M8/M8 "COVAL BUS" 120 Q TERMINATION Male M8/Female M8 cable Integrating a 120 Q termination resistor. The termination must be Integrated on the last"secondary" module of the COVAL Bus, between the final M8 connector of the product and the 24V DC electric supply. See "Accessories", page 9. vacuum managers Common specifications ■ Supply: Non-lubricated air 5 microns filtered, according to ISO 8573-1 Class 4 standard. ■ Operating pressure: 4.5 to 7 bar. ■ Mini dynamic pressure: -...

Open the catalog to page 11

All COVAL catalogs and technical brochures

  1. CVGL