Correction Factor: The document provides a correction factor table for different viscosities measured in centistokes (cSt). The correction factors range from 0.4 for cSt 22 to 4.6 for cSt 220.
Performance Diagram: The performance diagram illustrates the relationship between oil flow (l/min) and cooling capacity (kcal/h°C or kW/°C) for various models (M55-40 to M55-120). The diagram shows how the cooling capacity increases with the oil flow rate.
Loss of Pressure Diagram: This diagram shows the pressure loss (Bar) against the oil flow rate (l/min) for different models. It indicates how pressure loss varies with flow rate for each model, from M55-40 to M55-120.
Technical Specifications Table: The table lists the technical specifications for different models (M55-40 to M55-120), including surface area (m²), oil flow range (l/min), cooling capacity range (kW/°C), weight (kg), and dimensions (A). Key data includes:
- M55-40: Surface 2.8 m², Oil flow 80-240 l/min, Cooling capacity 0.68-3.24 kW/°C, Weight 25.7 kg, Dimension 115 A.
- M55-120: Surface 8.4 m², Oil flow 200-440 l/min, Cooling capacity 4.41-8.00 kW/°C, Weight 60.9 kg, Dimension 323 A.