Correction Factor: The correction factor table provides values for different kinematic viscosities (cSt) ranging from 22 to 220, with corresponding factors (f) from 0.4 to 4.6.
Performance Diagram: The performance diagram illustrates the relationship between oil flow (l/min) and cooling capacity (kW/°C) for different models (M25-30 to M25-80). The diagram shows how the cooling capacity increases with the oil flow rate.
Loss of Pressure Diagram: This diagram shows the pressure loss (Bar) against oil flow (l/min) for the same models. It indicates how pressure loss varies with the flow rate.
Technical Specifications Table: The table provides detailed specifications for each model (M25-30 to M25-80), including surface area (m²), oil flow range (l/min), cooling capacity range (kW/°C), weight (kg), and dimensions (A). The M25-80 model has the largest surface area and highest cooling capacity, while the M25-30 model has the smallest.