WRA ErP - Chiller - 1

Air cooled - 5 - 47,5 kW ErP2021 - R410A - R134A - Scroll compressor design that has focused on , , and . Thanks to dedicated technological solutions such as the oversized heat exchangers, the standard electronic expansion valve and the performances that imposed by the Ecodesign directive starting from 2021. Process chillers work with high heat loads continuously throughout the year. It is therefore very important that the chiller guarantees the highest performance the best solution for all process applications Thanks to the dedicated versions and accessories, operation at full load is guaranteed up to +45 °C outside air temperature during the summer season and -20 °C during the winter season in the LT version. a maximum evaporator outlet temperature of up to +30 °C; minimum standard temperature +5 °C and -10 The new LT versions for low ambient temperature -20°C, the Brine version for low water outlet temperature Tw10°C, and the new version for pressurised hydraulic range, which is therefore able to meet the most varied EER (without pump) (2) Power Supply Power Supply Auxiliaries feed General Features Pump P3 absorbed power Cooling Capacity 5 – 47,5 kW Power Supply: 400Vac - 3ph - 50Hz 460Vac - 3ph - 60Hz IP54 Protection Degree: suitable for outdoor installation Scroll compressors Plate/shell evaporator Non-Ferrous Hydraulic Circuit Electrical data safety of the production process in which the chiller is integrated.The Process version (mod.0A-5A) includes a shell and tube evaporator. Technical Data N° Compressors / N° Cooling circuits N° Axial Fans @50Hz Noise Level (4) Hydraulic connections Tank Volume (1) Data referring to outlet water inlet temperature 20/15°C - Air temperature 32°C. @50Hz (2) Data referring to outlet water inlet temperature 12/7°C - Air temperature 35°C. @50Hz (3) Data declared according to European Regulation (EU) 2016/2281 for high temperature process chillers (5) Weight of the unit with tank and P3 pump without options/kit. Tolerance +/-10%. Electrical data Power Supply Power Supply Auxiliaries feed Tank Volume IP Protection Degree Technical Data N° Compressors / N° Cooling circuits N° Axial Fans Pump P3 absorbed power Noise Level (4) Hydraulic connections (1) Data referring to outlet water inlet temperature 20/15°C - Air temperature 32°C. @50Hz (2) Data referring to outlet water inlet temperature 12/7°C - Air temperature 35°C. @50Hz (3) Data declared according to European Regulation (EU) 2016/2281 for high temperature process chillers (5) Weight of the unit with tank and P3 pump without options/kit. Tolerance +/-1

Open the catalog to page 1
WRA ErP - Chiller - 2

Electrical data Electrical data Power Supply Power Supply Auxiliaries feed Technical Data Power Supply Power Supply Auxiliaries feed IP Protection Degree Technical Data N° Compressors / N° Cooling circuits N° Compressors / N° Cooling circuits Pump P3 absorbed power Tank Volume Tank Volume N° Axial Fans Pump P3 absorbed power Noise Level (4) Hydraulic connections Hydraulic connections (1) Data referring to outlet water inlet temperature 20/15°C - Air temperature 32°C. @50Hz (2) Data referring to outlet water inlet temperature 12/7°C - Air temperature 35°C. @50Hz (3) Data declared according...

Open the catalog to page 2

All COSMOTEC catalogs and technical brochures

  1. WSW Techno

    2 Pages

  2. XVA

    4 Pages

  3. Slim In CDE

    5 Pages

  4. FlexIn CDI

    3 Pages

  5. Protherm

    12 Pages