Predator - Outdoor Air conditioner
3Pages

{{requestButtons}}

Catalog excerpts

Predator  - Outdoor Air conditioner - 1

Predator Outdoor Free Cooling operation, while compressor and condenser fan are Thanks to the direct use of external air, whenever the external air temperature is lower than the internal Direct free cooling combined with emergency ventilation guarantees service continuity, even in the event of a main power failure, if the operating conditions can guarantee the functioning. Direct Free Cooling is the best solution for energy saving and ensures a considerable cost reduction. How does Free Cooling work? An alternative system to direct expansion cooling, cabinet. The system automatically expels hot air from the cabinet, Predator air conditioners, thanks to their high air solution for energy saving. Whenever environmental conditions allow it, Predator works in free cooling mode; in this mode the evaporator fan is the only component in 48 VDC version The 48Vdc version is particularly suitable for cabinets powered by renewable energy sources, such as solar, wind or battery backup. Main Features • • • • Cooling Capacity 1000/2000W Functioning up to +60°C (ambient temperature) Industrial air conditioners for electrical panels Pr

Open the catalog to page 1
Predator  - Outdoor Air conditioner - 2

PRT10H/F CODE Power Supply Cooling Capacity Cooling Capacity Start-up current Internal operating temp.. External operating temp. Internal circuit protection degree External sound pressure PRT14H/F CODE Power Supply Cooling Capacity Cooling Capacity Power consumption - L35L50 Current consumption - L35L35 Start-up current Internal operating temp.. External operating temp. Internal circuit protection degree External sound pressure Weigth Industrial air conditioners for electrical panels Predator

Open the catalog to page 2
Predator  - Outdoor Air conditioner - 3

PRT20H/F PRT200 CODE Power Supply Cooling Capacity Cooling Capacity Power consumption - L35L50 Current consumption - L35L35 Start-up current Internal operating temp.. External operating temp. Internal circuit protection degree External sound pressure Optional Predator PRT CODE Free Cooling Emergency Ventilation Electrical Heating Accessories Predator PRT CODE ACTBSFPRT01FC Industrial air conditioners for electri

Open the catalog to page 3