Quality Grade Selection Chart Overview
This document provides a chart for selecting quality grades based on inclusion class and homogeneity in glass materials. The chart categorizes grades from AA to G, with specific parameters for total inclusion cross-section and maximum size of inclusions.
Inclusion Class and Homogeneity
  • Homogeneity: Measured in parts per million (ppm), with classes 3 and 4 specified.
  • Grade Class: Ranges from AA to G, with corresponding total inclusion cross-section and maximum size parameters.
Grade Specifications
  • AA: Total inclusion cross-section of 0.5 mm2, maximum size of 0.03 mm.
  • A: Total inclusion cross-section of 1 mm2, maximum size of 0.10 mm.
  • B: Total inclusion cross-section of 1.5 mm2.
  • C: Total inclusion cross-section of 2 mm2.
  • D: Total inclusion cross-section of 3 mm2.
  • E: Total inclusion cross-section of 4 mm2.
  • F: Total inclusion cross-section of 5 mm2.
  • G: Not Specified (NS).
Additional Notes
  • The sum of the cross-section in mm2 of inclusions is defined per 100 cm3 of glass, disregarding inclusions with a diameter less than 0.10 mm.
  • The diameter of the largest single inclusion is specified.
  • Index homogeneity is measured using an interferometer at 632.8 nm, with numerical homogeneity reported as the average through the piece thickness.
  • Blanks up to 450 mm in diameter can be analyzed over the full aperture, while larger parts require multiple overlapping apertures.
  • The minimum thickness for index homogeneity verification is 20 mm; thinner parts are certified based on the parent piece.
See more

Catalog excerpts

HPFSQualityGradeChart-1

Inclusion Class 1. Defines the sum of the cross section in mm2 of inclusions per 100 cm3 of glass. Inclusions with a' diameter < 0.10 mm are disregarded. 2. Refers to the diameter of the largest single inclusion. 3. Index homogeneity: the maximum index variation (relative), measured over the clear aperture of the blank. 4. Index homogeneity is certified using an interferometer at 632.8 nm. The numerical homogeneity is reported as the average through the piece thickness. Blanks with a diameter up to 450 mm can be analyzed over the full aperture. Larger parts can be analyzed using multiple overlapping apertures. The minimum thickness for index homogeneity verification is 20 mm. For thinner parts, the parent piece is certified.

 Open the catalog to page 1

All CORNING catalogs and technical brochures

  1. ActiFi®

    4  Pages

  2. OM2

    4  Pages

  3. OS2

    4  Pages

  4. OM1

    4  Pages

  5. HPFS®

    8  Pages

  6. Celcor®

    2  Pages

  7. CORE PRODUCTS

    62  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.