Correct Use of the ProductThe COREMO OCMEA
air-cooled brakes must be used within specified conditions and technical specifications. Exceeding maximum data is not recommended. Proper selection and application are crucial, with the Technical Department available for assistance. Correct mounting and maintenance are necessary to prevent accidents and ensure longevity. Initial torque may be 30% to 50% less than catalog values until linings settle on the discs.
Precautions for Mounting and MaintenanceOperators should wear protective clothing, including gloves and safety glasses. Moving parts must be protected per EEC directives. Although the brakes use non-asbestos friction material, dust inhalation should be avoided. Oils and greases are used minimally, and protective creams are recommended for those with allergies.
Storage and DisposalSafe storage and lifting should consider the product's weight. Worn linings and materials are non-toxic and should be disposed of according to local laws. In case of fire, rubber components may release toxic gases, necessitating the use of appropriate masks.
Selection and Technical DataSelection of tensioning brakes requires data on total tension, reel diameters, and linear speed. Technical data for various brake models include dynamic torque, maximum speed, inertia, air volume, and weight. Initial torque may be significantly less than nominal values until friction surfaces are properly worn in.
Heat DissipationA heat dissipation diagram is included, indicating continuous heat dissipation at a working temperature of 180°C (356°F).
Spare Parts ListA list of spare parts for air-cooled brakes is provided, including components like the thruster assembly, disc, hub, screws, and washers.