Introduction
The EnviroMate™ Benchtop Environmental Chamber is designed for testing orally inhaled and nasal drug products (OINDPs). It addresses variability in testing due to environmental conditions, which can affect dose emission and aerosol generation performance.

Sources of Testing Variability
Variability in OINDP testing can arise from factors such as temperature, humidity, and electrostatic charge. These factors impact delivered dose uniformity (DDU) and aerodynamic particle size distribution (APSD). Effective environmental control is crucial for accurate and reproducible test results.

Environmental Control Features
The EnviroMate™ chamber maintains uniform temperature and humidity, minimizing electrostatic charge effects. It is ideal for laboratories with variable conditions and OINDPs sensitive to environmental changes. The chamber is compact, requires no routine maintenance, and is cost-effective.

Key Features
  • Temperature and humidity sensors for accurate performance.
  • Anti-static system to reduce electrostatic variability.
  • Easy access and handling with large entry ports and a hinged door.
  • Quick-release connectors for ancillary equipment.
  • Visible and adjustable temperature and humidity settings.

Technical Specifications
  • Temperature Control Range: 17 - 35ºC, Accuracy: ±2ºC.
  • Humidity Control Range: 15 - 85% RH, Accuracy: ±5% RH.
  • Sound Level: 63 dBA at 1m.
  • Power Supply: 230V, 50Hz or 115V, 60Hz.
  • Capacity: 280 litres.

Applications
The EnviroMate™ is compatible with various inhaler testing apparatus, including the Next Generation Impactor (NGI), Andersen Cascade Impactor (ACI), and others. It supports testing with nebulisers and other OINDPs.

Conclusion
The EnviroMate™ provides a reliable solution for controlling environmental conditions in OINDP testing, enhancing data accuracy and repeatability while being a cost-effective alternative to dedicated climate-controlled laboratories.
See more

Catalog excerpts

EnviroMate™ Benchtop Environmental Chamber-1

Benchtop Environmental Chamber 2024 Edition

 Open the catalog to page 1
EnviroMate™ Benchtop Environmental Chamber-2

OINDP Testing Variability and Environmental Conditions Many factors have been identified that could give rise to variability in the testing of orally inhaled and nasal drug products (OINDPs). Each of these factors reduces the discriminatory power of tests to accurately determine product variability. Effective strategies to mitigate sources of variability in delivered dose uniformity (DDU) testing and aerodynamic particle size distribution (APSD) measurement have been the focus of rigorous investigation for many years. Environmental conditions is one key area.

 Open the catalog to page 2
EnviroMate™ Benchtop Environmental Chamber-3

Localised changes in laboratory temperature and humidity, and also the presence of electrostatic charge, are known to have a direct influence on the dose emission and aerosol generation performance of OINDPs, thereby compromising DDU and APSD test data integrity. • Particle/droplet evaporation effects for MDIs, nebulisers, ADIs, nasal sprays and aerosols • Accuracy of volumetric air flow rate measurements during testing • Particle/droplet evaporation effects for MDIs, nebulisers, ADIs, nasal sprays and aerosols • Water absorption effects for hygroscopic powder-based DPI formulations • Electrostatic...

 Open the catalog to page 3
EnviroMate™ Benchtop Environmental Chamber-4

Inhaler Testing EnviroMate Inadequate control of environmental conditions can affect the dose emission and aerosol generation performance of OINDPs, leading to erroneous data and costly testing delays. EnviroMate is a cost-effective, compact, benchtop solution that addresses these issues with considerable value for scientists faced with: • variable laboratory conditions or inadequate climate control • OINDPs with high sensitivity to temperature, humidity and/or electrostatic charge • poor reproducibility and unexplained out-of-specification (OOS) results • achieving better environmental control,...

 Open the catalog to page 4
EnviroMate™ Benchtop Environmental Chamber-5

Key Features: Sensitive temperature and relative humidity sensor ensures accurate performance Adjacent holder for BAC 100i/ TPK 100i Temperature and Relative Humidity Sensor included Anti-static system minimises electrostaticinduced variability Internal light maximises visibility Easy-to-remove water supply/waste reservoirs Temperature and relative humidity parameters are easily set and clearly visible to users Large, slot-sealed entry ports enable easy handling of test equipment A large, hinged door provides easy access Access ports and built-in quick-release connectors accommodate a wide range...

 Open the catalog to page 5
EnviroMate™ Benchtop Environmental Chamber-6

Inhaler Testing Read the Full Application Note EnviroMate™ Performance Data EnviroMate has been specifically designed to accommodate a wide range of inhaler testing apparatus, including: • Next Generation Impactor (NGI) and Glass Twin Impinger (GTI) Heat & Dehumidify • Inhaler Testing Workstation™ ITW with DUSA for MDIs and DPIs, Waste Shot Collector WSC2, Andersen Cascade Impactor (ACI) and Multi-Stage Liquid Impinger (MSLI) EnviroMate Performance Envelope Heat & Humidify EnviroMate can also interface with the BRS 200i and NGI Cooler™ for nebuliser testing, and flow controllers and vacuum pumps...

 Open the catalog to page 6
EnviroMate™ Benchtop Environmental Chamber-7

EnviroMate with Next EnviroMate with Inhaler Testing EnviroMate with Andersen Generation Impactor (NGI) Workstation™ ITW and DUSA for DPIs Cascade Impactor (ACI) EnviroMate with Breathing Simulator BRS 200i for nebuliser testing EnviroMate™Cat. No. Description 5040 EnviroMate™ Environmental Chamber 5042 IQ/OQ Documentation for EnviroMate™ 5043 Qualification Tools for EnviroMate™ 5044 Recalibration of EnviroMate™ Qualification Tools

 Open the catalog to page 7
EnviroMate™ Benchtop Environmental Chamber-8

COPLEY Copley Scientific Limited Colwick Quays Business Park, Road No.2 Nottingham, NG4 2JY United Kingdom © 2023 Copley Scientific Limited. All rights reserved.

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.