Overview: The document provides comprehensive technical specifications and operational guidelines for the Xenus Plus CANopen digital servo drive by Copley Controls, as well as the XPL-NK CAN Connector Kit. It covers the drive's capabilities, control modes, communication interfaces, feedback options, safety features, and network configurations.
Specifications: The Xenus Plus models (XPL-230-18, XPL-230-36, XPL-230-40) operate with a mains voltage of 100-240 Vac and offer peak currents of 18, 36, and 40 Adc respectively. They support various control modes, including Profile Position, Velocity, and Torque, and feature CANopen and RS-232 communication interfaces. The XPL-NK CAN Connector Kit includes an adapter for converting a D-Sub 9M connector to an RJ-45 Ethernet socket, a 10 ft cable, and a terminator, conforming to the CiA DR-303-1 specification.
Control and Communication: The drive supports CANopen DS-402 and RS-232 for communication, operating in distributed or stand-alone modes. Node addresses in a CANopen network range from 1 to 127, set using rotary switches. The RS-232 port supports full-duplex communication with baud rates from 9600 to 115,200.
Feedback and I/O: The drive supports incremental and absolute encoders, digital halls, and resolver feedback. It includes 15 digital inputs, 6 digital outputs, and several analog inputs and outputs. Command inputs include digital position, torque, and velocity formats, with a multi-mode encoder port for feedback signals.
Safety and Protection: The Safe Torque Off (STO) feature ensures safety by disabling the power stage when necessary. The drive includes protections against overvoltage, undervoltage, overtemperature, and short circuits. The STO function complies with IEC 61800-5-2 standards.
Mechanical and Environmental: The drive's dimensions are 7.9 x 5.5 x 2.3 inches, operating within a temperature range of 0 to +45°C. It complies with various EMC and safety standards, ensuring reliable operation in industrial environments.
Best Practices: Recommendations include ensuring proper grounding for CE compliance and using external regeneration resistors for energy dissipation. Grounding and shielding are critical for controlling radio frequency emissions.
Procedures: Installation procedures emphasize using shielded cables for CE compliance and proper grounding to prevent electrical hazards. A wire insertion/extraction tool is recommended for cable connections.
Standards and Compliance: CE compliance requires line filters and shielded cables. The document specifies the use of ferrite cores for shielded cables connected to the regen resistor.
Grounding and Safety: Grounding requirements emphasize connecting the safety ground terminal at the mains connector with a wire of the same gauge as the mains. This connection is crucial for carrying fault current to earth ground in case of a short-circuit.
Heatsink and Fan Configurations: Installation procedures for heatsinks involve using a dry-film interface pad. Various configurations are available, including no heatsink, low-profile heatsink, and standard heatsink, with or without fans.
Performance Charts: Charts illustrate the relationship between maximum ambient temperature and continuous output current for different Xenus Plus models, showing how heatsink and fan combinations affect operating temperature range.
Ordering Guide: An ordering guide details model numbers, current ratings, and optional features like resolver options. It lists available accessories, including connector kits, software CDs, serial cable kits, and heatsink kits.
Accessories and Installation Notes: Additional accessories such as regeneration resistors and edge filters are mentioned, with specific part numbers and configurations. An example order illustrates how to specify a drive with a factory-fitted heatsink and other accessories.
See more

Catalog excerpts

Xenus RoHS PLUS CANopen-1

Xenus PLUS Control Modes • Profile Position-Velocity-Torque, Interpolated Position, Homing • Camming, Gearing • Indexer Command Interface • CANopen • ASCII and discrete I/O • Stepper commands • ±10V position/velocity/torque (2 inputs) • PWM velocity/torque command • Master encoder (Gearing/Camming) Communications • CANopen DS-402 • RS-232 Feedback Incremental Incremental Encoders • Digital quad A/B Analog Sin/Cos Panasonic Incremental A Format • Aux. quad A/B encoder / encoder out Absolute Encoders • SSI, EnDat, Absolute A, Tamagawa & Panasonic Absolute A Sanyo Denki Absolute A, BiSS (B & C) Resolver (-R option) • Brushless Resolver Other • Digital Halls Accessories • External regen resistors • External edge filter Safe Torque Off (STO) • Two active inputs enable power stage • One output confirms power stage status I/O Digital • 15 inputs, 6 outputs I/O Analog • 2, 16-bit inputs • 1, 12-bit input • 1, 12-bit output Dimensions: in [mm] • 7.9 x 5.5 x 2.3 [202 x 139 x 52] XPL CANopen RoHS DIGITAL SERVO DRIVE FOR BRUSH/BRUSHLESS MOTORS R Model Vac Ic Ip XPL-230-18 100 - 240 6 18 XPL-230-36 100 - 240 12 36 XPL-230-40 100 - 240 20 40 Add -R for resolver feedback option DESCRIPTION Xenus Plus set new levels of performance, connectivity, and flexibility. CANopen communication provides a widely used cost-effective industrial bus. A wide range of absolute interfaces are built-in including EnDat, Hiperface, and BiSS. High resolution A/D converters ensure optimal current loop performance. Both isolated and highspeed non-isolated I/O are provided. For safety critical applications, redundant power stage enable inputs can be employed. Copley Controls, 20 Dan Road, Canton, MA 02021, USA Tel: 781-828-8090 Tech Support: E-mail: [email protected], Web: http://www.copleycontrols.com Fax: 781-828-6547 Page 1 of 28

 Open the catalog to page 1
Xenus RoHS PLUS CANopen-2

Xenus PLUS CANopen XPL RoHS GENERAL SPECIFICATIONS Test conditions: Wye connected load: 2 mH line-line. Ambient temperature = 25 °C. Power input = 230 Vac, 60 Hz, 1 Ø MODEL XPL-230-18 XPL-230-36 XPL-230-40 OUTPUT CURRENT Peak Current 18 (12.7) 36 (25.5) 40 (28.3) Adc (Arms, sinusoidal) Peak time 1 1 1 s Continuous current (Note 1) 6 (4.24) 12 (8.5) 20 (14.1) Adc (Arms, sinusoidal) INPUT POWER Mains voltage, phase, frequency 100~240 Vac, ±10%, 1Ø or 3Ø, 47~63 Hz 10.1 20.0 20.0 Arms Maximum Mains Current, 1Ø (Note 3) 6.4 10.4 15.4 Arms Maximum Mains current, 3Ø (Note 3) +24 Vdc Control power +20...

 Open the catalog to page 2
Xenus RoHS PLUS CANopen-3

Two independent 5 Vdc @ 400 mA outputs, thermal and short-circuit protected Cut-in Voltage Drop-Out Voltage Internal solid-state switch drives external regen resistor (see Ordering Guide for types) +HV > 390 Vdc Regen output is on, (optional external) regen resistor is dissipating energy +HV < 380 Vdc Regen output is off, (optional external) regen resistor not dissipating energy ±2 Vdc_For either Cut-in or Drop-Out voltage_ Drive over temperature Short circuits Motor over temperature _Feedback power loss +HV > 400 Vdc Drive PWM outputs turn off until +HV is less than overvoltage +HV < 60 Vdc...

 Open the catalog to page 3
Xenus RoHS PLUS CANopen-4

Xenus PLUS CANopen XPL RoHS SPECIFICATIONS (CONT’D) SAFE TORQUE OFF (STO) Inputs 2 two-terminal: [ENH+], [ENH-], [ENL+], [ENL-] Type Opto-isolators, 24V compatible Output 1 two-terminal: [LED+], [LED-] 24V compatible Functional Safety IEC 61508-1, IEC 61508-2, EN(ISO) 13849-1, EN(ISO) 13849-2 DIMENSIONS Inches (mm) 7.92 201.17 7.54 191.52 .19 4.83 R.094 2.37 TYP 1.29 32.69 5.12 130.07 Chassis Grounding: For CE compliance and machine safety an electrically conductive grounding tab is provided. This connects to the heatplate and to frame ground. 3.00 76.20 Chassis grounding tab CAN .190 4.83 .24...

 Open the catalog to page 4
Xenus RoHS PLUS CANopen-5

Xenus PLUS XPL CANopen RoHS CANOPEN Based on the CAN V2.0b physical layer, a robust, two-wire communication bus originally designed for automotive use where low-cost and noise-immunity are essential, CANopen adds support for motion-control devices and command synchronization. The result is a highly effective combination of data-rate and low cost for multi-axis motion control systems. Device synchronization enables multiple axes to coordinate moves as if they were driven from a single control card. CANOPEN COMMUNICATION Xenus uses the CAN physical layer signals CAN_H, CAN_L, and CAN_GND for connection,...

 Open the catalog to page 5
Xenus RoHS PLUS CANopen-6

Xenus PLUS XPL CANopen RoHS COMMUNICATIONS RS-232 COMMUNICATIONS XPL is configured via a three-wire, full-duplex DTE RS-232 port that operates from 9600 to 115,200 Baud, 8 bits, no parity, and one stop bit. Signal format is full-duplex, 3-wire, DTE using RxD, TxD, and Gnd. Connections to the XPL RS-232 port are through J7, an RJ-11 connector. The XPL Serial Cable Kit (SER-CK) contains a modular cable, and an adapter that connects to a 9-pin, Sub-D serial port connector (COM1, COM2, etc.) on PC’s and compatibles. STAT LED (ON J6) J6: RS-232 PORT SIGNAL 1 STAT PIN 2 RxD 6 RJ-11 receptacle, 6 position,...

 Open the catalog to page 6
Xenus RoHS PLUS CANopen-7

Xenus PLUS XPL CANopen RoHS SAFE TORQUE OFF (STO) DESCRIPTION The XPL has a safety feature that is designed to provide the Safe Torque Off (STO) function as defined in IEC 61800-5-2. Two opto-couplers are provided which, when de-energized, prevent the upper and lower devices in the PWM outputs from being operated by the digital control core. This provides a positive OFF capability that cannot be overridden by the control firmware, or associated hardware components. When the opto-couplers are activated (current is flowing in the input diodes), the control core will be able to control the on/off...

 Open the catalog to page 7
Xenus RoHS PLUS CANopen-8

Xenus PLUS XPL CANopen RoHS COMMAND INPUTS DIGITAL POSITION Digital position commands can be in either single-ended or differential format. Single-ended signals should be sourced from devices with active pull-up and pull-down to take advantage of the high-speed inputs. Differential inputs have 121 Ω line-terminators. DIFFERENTIAL PULSE & DIRECTION SINGLE-ENDED PULSE & DIRECTION [IN3+] [IN5] [IN6] [IN4-] Pulse PULSE Direction [IN5+] [IN6-] SINGLE-ENDED CU/CD DIRECTION DIFFERENTIAL CU/CD CU (Count-Up) CU (Count-Up) [IN5] [IN6] [IN3+] [IN4-] CU CD CD (Count-Down) CD (Count-Down) [IN5+] [IN6-] QUAD...

 Open the catalog to page 8

All Copley Controls catalogs and technical brochures

  1. Selection Guide

    24  Pages

  2. Xenus R10

    30  Pages

  3. Accelnet R23

    24  Pages

  4. Accelnet R22

    22  Pages

  5. Accelnet R21

    24  Pages

  6. Accelnet R20

    24  Pages

  7. Accelus Card

    8  Pages

  8. Junus

    10  Pages

  9. CAN-PCI-02

    2  Pages

  10. CAN-IPM-01

    8  Pages

  11. Bantam

    18  Pages

  12. Bantam R30

    18  Pages

  13. 503

    6  Pages

  14. Xenus Micro

    24  Pages

  15. Accelus Card

    8  Pages

  16. Accelus Panel

    10  Pages

  17. Xenus XTL

    30  Pages

  18. Accelnet Module

    14  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.