1. Catalogs
  2. Copley Controls
  3. Power Supply Subsystem

Power Supply Subsystem
1 /8Pages

Power Supply Subsystem

Power Supply Subsystem
1 /8Pages

Catalog excerpts

Power Supply Subsystem-1

PST/PSX Series Unregulated Power Supplies for PWM Servo Amplifiers FEATURES • Linear, unregulated power for PWM servo amplifiers. • Power, Mounting, and Cooling for 1~6 amplifiers • Optional fan-bar holds three 3.15” fans. DESCRIPTION • PST Models utilize an internal toroidal transformer PST/PSX models are linear, unregulated power supplies designed to be used with Copley Controls PWM servo amplifiers. They provide DC power, mounting, and (optional) cooling for 1-6 servo amplifiers. • PSX Models require an external transformer ( single or 3 phase ) • Thermal circuit breakers on AC power inputs eliminate inrush tripping at power on, permit fast reset in field. • Screw-terminal connections for mains wiring and motor power connections. THE OEM ADVANTAGE • Add amplifiers for complete drive subsystem. • Small footprint ( 7” X 11.5” ) • Dual AC-voltage models for OEM flexibility when shipping to international markets The small footprint takes advantage of the fact that multipleamplifier installations seldom operate at the maximum continuous power rating of each individual amplifier. Particularly in incremental motion applications, machine design commonly prevents simultaneous movement of all axes, and when motion occurs, it requires less than the amplifiers peak rating. This package was developed to put the largest possible transformer into the smallest package that would mount up to six amplifiers. The 750W output rating of the PST models (630W for dual-voltage PST-DP models) is sufficient to drive the majority of applications, given the varying duty cycles and power outputs of the mounted amplifiers. When higher power is required, the PSX models utilize external isolation transformers to increase unit power ratings to 1500W. The PSX series require either single or three-phase isolation transformers and incorporate extra capacitance internally. Model PST-075 and PST-150 provide +75VDC and +150VDC respectively for powering Copley Controls Corp. amplifiers that operate from +24 to +90VDC, and +24 to +180VDC. When utilizing lower voltage amplifiers such as Models 403, 405, 503, and 505 that operate from +18 to +55VDC, Model PST-040-13-DP supplying +40VDC is available. , PEM fasteners on top plate provide easy mounting of 1 to 6 amplifiers in a 7.0 X 11.5 in. footprint. An optional fanbar mounts three high efficiency 3.15” fans for direct, forced-air cooling when required. An optional extension plate adapts the larger amplifiers (Models 513 and 5xx1 series), increasing the footprint to 9.35” X 11.5”. Standard PST models operate from USA standard mains (120VAC at 60Hz) and output 75 or 150VDC with a 750W rating. For international power operation, PST-DP models offer switchselection of mains voltages: 115/230VAC at 50/60Hz in three output voltages. 261

 Open the catalog to page 1
Power Supply Subsystem-2

PST/PSX Series Unregulated Power Supplies for PWM Servo Amplifiers APPLICATION INFORMATION GENERAL SPECIFICATIONS PST MODELS Ripple Voltage 2%V at full load Environmental Operating temperature range: 0° C to 50° C. Derating: 0.86%/°C from 50°C to 65 °C. Grounding TB1 ground pin connects to chassis “star” ground point. Chassis grounding lug provided. Output filter capacitor (-) terminal connects to chassis star ground internally. Peak output current 2.5X rated continuous current for 1s. at 20% duty cycle. These models employ internal toroidal transformers and connect directly to the mains. There...

 Open the catalog to page 2
Power Supply Subsystem-3

PST/PSX Series Unregulated Power Supplies for PWM Servo Amplifiers PST MODELS FOR 120VAC, 60HZ FUNCTIONAL DIAGRAM TB2 FAN (3) TB1 N.C. N.C. GND 120VAC 60Hz NEUT HOT N.C. (FANS OPTIONAL) TB3 1 2 3 4 5 6 F1 + C +HV R Vs Vp CB GND Vs Chassis Note: Secondary configuration shown above represents PST-75-10 Model PST-75-10 PST-150-05 C 20,000µF 6,800µF R 3.9k 6.8k CB 15A 15A PANEL LAYOUT CB ! TO AVOID SHOCK HAZARD WAIT 5 MINUTES AFTER UNIT IS TURNED OFF BEFORE SERVICING. N.C. 1 1 N H 2 3 4 5 N.C. 2 3 4 5 N.C. 6 6 TB2 Test conditions: 120VAC, 60Hz. mains power. RATINGS Model Output Power @ Full Load...

 Open the catalog to page 3
Power Supply Subsystem-4

PST/PSX Series Unregulated Power Supplies for PWM Servo Amplifiers PST-DP MODELS FOR 115/230VAC, 50/60HZ FUNCTIONAL DIAGRAM FAN F1 TB1 N.C. N.C. GND 115/230VAC 50/60Hz NEUT HOT N.C. CB1 15A 1 2 3 4 5 6 TB3 (3 FANS, OPTIONAL) + C T1 +HV R GND SW1 Voltage Select Chassis Note: Secondary configuration shown above represents PST-070-08-DP Model PST-70-08-DP PST-140-04-DP PST-040-13-DP C 20,000µF 6,800µF 47,000µF R 3.9k 6.8k 3.9k CB 15A 15A 15A PANEL LAYOUT CB ! TO AVOID SHOCK HAZARD WAIT 5 MINUTES AFTER UNIT IS TURNED OFF BEFORE SERVICING. N.C. 1 1 N H 2 3 4 5 N.C. 2 3 N.C. 6 4 5 6 TB2 ratings Test...

 Open the catalog to page 4
Power Supply Subsystem-5

PST/PSX Series Unregulated Power Supplies for PWM Servo Amplifiers PSX-3 MODELS ( EXTERNAL 3-PHASE TRANSFORMER ) FUNCTIONAL DIAGRAM TB2 FAN (3) TB1 (FANS OPTIONAL) TB3 F1 120VAC 60Hz T HOT 1 NEUT GND 2 X1 X2 X3 + + C +HV R 3 4 5 6 CB CB GND CB Chassis Note: Secondary configuration shown above represents PSX-3 Model PSX-065-17-3 PSX-140-10-3 C 40,000µF 13,600µF R 1.95k 3.4k CB 15A 15A T 53VAC secondary, 3-phase, 2kVA 106VAC secondary, 3-phase, 2kVA PANEL LAYOUT ! TO AVOID SHOCK HAZARD WAIT 5 MINUTES AFTER UNIT IS TURNED OFF BEFORE SERVICING. H 1 1 N 2 3 2 3 X1 X2 CB X3 5 6 4 5 6 4 TB2 RATINGS...

 Open the catalog to page 5
Power Supply Subsystem-6

PST/PSX Series Unregulated Power Supplies for PWM Servo Amplifiers PSX-1 MODELS ( EXTERNAL SINGLE-PHASE TRANSFORMER ) FUNCTIONAL DIAGRAM TB2 FAN (3) TB1 (FANS OPTIONAL) TB3 F1 120VAC 60Hz HOT NEUT GND T X1 X2 N.C. 1 2 3 4 5 6 + + C +HV R CB GND Chassis Model PSX-065-17-1 PSX-140-10-1 C 40,000µF 13,600µF R 1.95k 3.4k CB 30A 30A T 53VAC secondary, 1-phase, 2kVA 106VAC secondary, 1-phase, 2kVA PANEL LAYOUT ! TO AVOID SHOCK HAZARD WAIT 5 MINUTES AFTER UNIT IS TURNED OFF BEFORE SERVICING. 30 H 1 1 N X1 X2 2 3 4 5 2 3 4 5 CB N.C. 6 6 TB2 RATINGS Model PSX-065-17-1 PSX-140-10-1 Test conditions: 53VAC...

 Open the catalog to page 6
Power Supply Subsystem-7

PST/PSX Series Unregulated Power Supplies for PWM Servo Amplifiers Layout Notes: Please use these views of a PST/PSX for layout purposes when ordering Copley servoamps (refer back to page 2 for more details on sizing of typical servoamplifiers.) EXTENDER PLATE (OPTIONAL) 7.90 (200.7) TB1 9.35 237.5) 4.92 (125.0) 7.00 (177.8) 4.92 (125) TB3 F1 0.98 (24.9) 0.98 (24.9) 0.38 (9.65) 10.75 (273) 11.5 (292) FAN ASSEMBLY (OPTIONAL) AMPLIFIER LOCATION When ordering, use this chart to specify the location of the amplifiers in your system. For example, you might order a PST-075-10-F with two model 412 amplifiers...

 Open the catalog to page 7

All Copley Controls catalogs and technical brochures

  1. Selection Guide

    24  Pages

  2. Xenus R10

    30  Pages

  3. Accelnet R23

    24  Pages

  4. Accelnet R22

    22  Pages

  5. Accelnet R21

    24  Pages

  6. Accelnet R20

    24  Pages

  7. Accelus Card

    8  Pages

  8. Junus

    10  Pages

  9. CAN-PCI-02

    2  Pages

  10. CAN-IPM-01

    8  Pages

  11. Bantam

    18  Pages

  12. Bantam R30

    18  Pages

  13. 503

    6  Pages

  14. Xenus Micro

    24  Pages

  15. Accelus Card

    8  Pages

  16. Accelus Panel

    10  Pages

  17. Xenus XTL

    30  Pages

  18. Accelnet Module

    14  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.