CAN-PCI-02-1

CAN-PCI-02 CAN-PCI CAN Interface Card for PCI 2.2 Features • CAN 2.0A and 2.0B • 2-Channels • Micro-controller • Up to 1 Mbit/sec • ISO 11898 transceivers Computer Interface RoHS R • PCI slot, Rev 2.2 • Fast dual-port RAM • 3.3 or 5 V Agency Approvals • CE, UL/CSA, FCC • RoHS 2002/95/EC CAN Monitor Software • View CAN messages • CAN bus loading • Diagnostics • Download firmware Plug-and-play • CML & CMO • Xenus • Accelnet • Stepnet DESCRIPTION A highly cost-effective dual-channel CAN card makes the connection between Copley’s distributed control software and CANopen servo and stepper drives. The two independent CAN ports are galvanically isolated to provide greater noise immunity in industrial environments. An on-board microcontroller off-loads tasks from the host computer enabling faster system performance. PCI compliant, it is compatible with both 3.3 Vdc and 5 Vdc computers. Copley Controls, 20 Dan Road, Canton, MA 02021, USA Web: http://www.copleycontrols.com The card employs high-speed ISO 11898 transceiver circuits for CAN bus bit-rates up to 1 Mbit/sec. Driver software for Windows XP, 2000, and Windows 7 is a free download from the Copley website. CMO (Copley Motion Objects) software, also available free on the web, works with Microsoft COM enabled computers for control of Copley’s CANopen servo amplifiers and stepper drivers from high-level languages such as Visual Basic and LabView. Tel: 781-828-8090 Fax: 781-828-6547 Page 1 of 2

 Open the catalog to page 1
CAN-PCI-02-2

CAN-PCI-02 CONNECTOR CAN-PCI RoHS MECHANICAL OUTLINE SUB-D 9M 1 6 CAN 2 9 TERMINATOR JUMPER CAN2 5 TERMINATOR JUMPER CAN1 CAN 1 SIGNALS & PINS PIN SIGNAL 1 N.C. 2 CAN_L 3 CAN_GND 4 N.C. 5 (CAN_SHLD) 6 (GND) 7 CAN_H 8 N.C. 9 (CAN_V+) SPECIFICATIONS Hardware requirements IBM PC or equivalent with PCI slot PCI Interface 32-bit, 3.3 & 5 V compatible, version 2.2 OS requirements Windows XP, 2000, Windows 7, or Linux CAN channels 2, independent, galvanically isolated CAN termination 121W each channel, jumper selectable CAN transceivers Philips TJA1050TD (ISO 11898 compliant) CAN bit rate 1 Mbit/sec...

 Open the catalog to page 2

All Copley Controls catalogs and technical brochures

  1. Selection Guide

    24  Pages

  2. Xenus R10

    30  Pages

  3. Accelnet R23

    24  Pages

  4. Accelnet R22

    22  Pages

  5. Accelnet R21

    24  Pages

  6. Accelnet R20

    24  Pages

  7. Accelus Card

    8  Pages

  8. Junus

    10  Pages

  9. CAN-IPM-01

    8  Pages

  10. Bantam

    18  Pages

  11. Bantam R30

    18  Pages

  12. 503

    6  Pages

  13. Xenus Micro

    24  Pages

  14. Accelus Card

    8  Pages

  15. Accelus Panel

    10  Pages

  16. Xenus XTL

    30  Pages

  17. Accelnet Module

    14  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.