MR 20 RC

MR 20 RC

MR 20 RC

Product catalog summary
General Overview
The MR 20 RC Chlorination System is engineered for dosing gas chlorine and can be adapted for other gases. It operates on an indirect vacuum principle and includes a vacuum regulator, ejector, and gas flowmeter. Manual dosing adjustments are made via the regulator's rate valve, with operation linked to the ejector pump's status.

Installation
Installation requires qualified experts to adhere to international standards for safety and reliability. An annual system overhaul by authorized service is mandatory.

System Extension Options
Multipoint Chlorination System: Additional gas flowmeters can be installed parallel to the existing one to extend the system to multiple dosing points, ensuring the regulator's capacity is not exceeded.
Semiautomatic Dosing System: In systems with multiple pumps, each can be equipped with an ejector and gas flowmeter, connected parallel to the regulator. Dosing can be controlled via an electromagnetic valve responding to flow changes.

Technical Specifications
The system supports a capacity of up to 15 kg/h and is designed for maximum safety with high-quality materials. It includes options for alarms, regulators, and various gas types. The dosing range varies from 12 g/h to 15,000 g/h, with different ejector types available based on pressure requirements.

Order Codes and Options
Order codes specify options such as alarm presence, regulator inclusion, gas type, dosing range, and ejector type. The system's technical data includes connection specifications, accuracy, operating range, weight, and packaging dimensions.
See more

Catalog excerpts

MR 20 RC-1

1 Dosing equipment for aggressive gases Full vacuum system for maximum safety Chlorine wetted parts made of high quality materials for maximum reliability SYSTEM EXTENSION OPTIONS The MR 20 RC System consists of: M 20 C vacuum regulator  M 300 C ejector  M 200 C gas flowmeter The MR 20 RC System can be extended by additional gas flowmeters, which have to be installed parallel to the existing one. This way the system can be extended to several dosing points, but in this case suitable ejector must be added to it. When adding gas flowmeters to the system, it is important not to exceed the capacity of the regulator. Multipoint chlorination system The MR 20 RC Chlorination System is designed for dosing gas chlorine and with minor alterations also for other gases, working on the indirect vacuum principle. Dosing can be set manually on the rate valve of the regulator. It starts or stops when the ejector pump switches on or off. It is very simple to mount vacuum regulators. However, installation of the devices must be done by qualified experts taking in consideration all required international standards in order to ensure safe and faultless operation. An authorized service must overhaul the system once a year. 1. Chlorine cylinder 2. Vacuum regulator 3. Gas flowmeter 4. Ejector 5. Booster pump Semiautomatic dosing system Where there are several pumps in the water-supply system with known capacities, each pump can be extended by an ejector and a gas flowmeter, and connected parallel to the regulator. Dosing can be blocked through electromagnetic valve. Activation of the electromagnetic valve depends on the known flow changes. 1.Chlorine Cylinder 2.Manifold with Accessories 3.Vacuum Regulator 4.Vacuum Tube 5.Electromagnetic Valve 6.Gas flowmeter 7.Ejector 8.Ejector Pump 9.Valves 10.Tube leading to use

 Open the catalog to page 1
MR 20 RC-2

1 Dosing equipment for aggressive gases ORDER CODES Model El. Alarm Signal (Full/Empty ) Regulator Gas type Dosing range Ejector Pressure Gauge(y/n) Yoke (clamp type) OPTIONS: - Alarm: yes “A”, without alarm the letter is not written in the code - Regulator: yes “R”, means system with all general parts - Gas type: “C” - Cl2, “CO2” - CO2, “S” - SO2, “N” - NH3 - Dosing range (g/h): 1 up to 12 2 up to 25 3 up to 100 4 up to 200 5 up to 500 6 up to 1000 7 up to 2000 8 up to 4000 9 up to 10000 15 up to 15000 - Ejector: “B” - D.P.T. : Ejector with PVC valves designed for pool engineering, for pressure...

 Open the catalog to page 2

All Controlmatik catalogs and technical brochures

  1. MR 50 RC

    2  Pages

  2. MR 40 RC

    2  Pages

  3. MR 21 RC

    2  Pages

  4. M 30 RC

    2  Pages

  5. M 470 C PVC

    2  Pages

  6. M 3800

    2  Pages

  7. M 2103 C

    2  Pages

  8. M 4510 C

    2  Pages

  9. M 5265 C

    2  Pages

  10. automation

    1  Page

  11. M 5700 C

    2  Pages

  12. M 1322

    2  Pages

  13. M 1122

    2  Pages

  14. M 1056 C

    2  Pages

  15. M 1036 C

    2  Pages

  16. M 1035 C

    2  Pages

  17. M 20 RC

    2  Pages

  18. M 3610 C

    2  Pages

  19. M 3480 C

    2  Pages

  20. M 3100 C

    2  Pages

  21. M 3319 C

    2  Pages

  22. M 3531 C

    2  Pages

  23. M 300 C

    2  Pages

  24. M 200 C

    2  Pages

  25. M 20 C

    2  Pages

  26. M 40 C

    2  Pages

  27. M 50 C

    2  Pages

  28. M 5262 C

    2  Pages

  29. M 5600 C

    2  Pages

  30. M 3521 C

    2  Pages

  31. M 40 C

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.