Catalog excerpts
Free Chlorine analyser M 1036 C 3 measuring electrodes platinum/platinum + reference electrode Stable measurement— open flow measurement cell with a constant flow Continuous cleaning of measuring electrodes Alarm for measuring cell or regulation errors CANbus communication to easily connect several units to the control unit Insight in measurement cell parameters for rapid detection of interfering substances Modular electronics for simple service Clear graphical display for all measured parameters Free residual chlorine analyser series M 1036 C is designed for measurement and control of drinking water, waste water treatment and swimming-pool applications. Two basic measured parameters are free chlorine and temperature. The unit enables the construction of additional expansion modules, for measuring the pH value and the redox potential (for drinking and waste water). The user interface for parameterization and calibration is performed via graphical LCD display. Control, regulation and control of disinfection processes are enabled by analog and digital outputs and the CANbus digital communication. The control module supports the connection of actuators - dosing pump with analog and digital inputs as well as solenoid and motorized valves - for two-point and continuous dosing. Software design of the control module contains a number of protective mechanisms against overdosing. Amperometric measurement method using two electrodes and an additional third reference electrode provides a constant and continuous measurements. The unit consists of the following subassemblies: a mechanical filter sample an indicator of the flow of the sample self-cleaning measuring cell measurement - regulation electroni
Open the catalog to page 12 Measuring & Control equipment ORDER CODE Free Chlorine analyser M1036 C Model Automatic temp. compensation - Default CAN Communication output - Default Output options (4-20mA) - Default Regulator - Optional Measuring range - See Options below Reference electrode - Default Flow indicator - Default OPTIONS: - Regulator: yes ''R'', without it the letter is not written in - Measuring range: ''1'' for 0 to 1 mgCl2/l (0 –5 mgCl2/l adjustable) ''X''- on request Standard models: Order Codes TECHNICAL DATA General data : Ambient temperature: Relative humidity: Control unit protection: Dimensions:...
Open the catalog to page 2All Controlmatik catalogs and technical brochures
-
MR 520 C, MR 540 C, MR 550 C
2 Pages
-
MR 50 RC
2 Pages
-
MR 40 RC
2 Pages
-
MR 21 RC
2 Pages
-
MR 20 RC
2 Pages
-
M 30 RC
2 Pages
-
M 470 C PVC
2 Pages
-
M 3800
2 Pages
-
M 2103 C
2 Pages
-
M 4510 C
2 Pages
-
M 5265 C
2 Pages
-
automation
1 Pages
-
M 5700 C
2 Pages
-
M 1322
2 Pages
-
M 1122
2 Pages
-
M 1056 C
2 Pages
-
M 1035 C
2 Pages
-
MR 520, 540 & 550 RC
2 Pages
-
M 20 RC
2 Pages
-
M 3610 C
2 Pages
-
M 3480 C
2 Pages
-
M 3100 C
2 Pages
-
M 3319 C
2 Pages
-
M 3531 C
2 Pages
-
M 300 C
2 Pages
-
DP 20, DP 40, DP 50
2 Pages
-
M 200 C
2 Pages
-
M 20 C
2 Pages
-
M 40 C
2 Pages
-
M 50 C
2 Pages
-
Compat filtration unit
2 Pages
-
Vacuum switchover M 400
2 Pages
-
Aquacon M 5500 C
2 Pages
-
M 5262 C
2 Pages
-
M 5600 C
2 Pages
-
M 1032 C/ADCR1
2 Pages
-
M 400 and M 440
2 Pages
-
M 3521 C
2 Pages
-
M 340 C and M 350 C
2 Pages
-
M 40 C
2 Pages
-
Vacuum Regulators M 50
2 Pages
-
Vacuum Regulators M 20
2 Pages