M 1035 C
2Pages

{{requestButtons}}

Catalog excerpts

M 1035 C - 1

Free Chlorine analyser M 1035 C  2 measuring electrodes gold/copper + reference electrode (optional) Stable measurement— open flow measurement cell with a constant flow Continuous cleaning of measuring electrodes Alarm for measuring cell or regulation errors CANbus communication to easily connect several units to the control unit Insight in measurement cell parameters for rapid detection of interfering substances Modular electronics for simple service Clear graphical display for all measured parameters Free residual chlorine analyser series M 1035 C is designed for measurement and control of drinking water, waste water treatment and swimming-pool applications. Two basic measured parameters are free chlorine and temperature. The unit enables the construction of additional expansion modules, for measuring the pH value and the redox potential (for drinking and waste water). The user interface for parameterization and calibration is performed via graphical LCD display. Control, regulation and control of disinfection processes are enabled by analog and digital outputs and the CANbus digital communication. The control module supports the connection of actuators - dosing pump with analog and digital inputs as well as solenoid and motorized valves - for two-point and continuous dosing. Software design of the control module contains a number of protective mechanisms against overdosing. Amperometric measurement method using two electrodes and an additional third reference electrode provides a constant and continuous measurements. The unit consists of the following subassemblies:  a mechanical filter sample  an indicator of the flow of the sample  self-cleaning measuring cell  measurement - regulation electroni

Open the catalog to page 1
M 1035 C - 2

2 Measuring & Control equipment ORDER CODE Free Chlorine analyser M1035 C Model Automatic temp. compensation - Default CAN Communication output - Default Output options (4-20mA) - Default Regulator - Optional Measuring range - See Options below Reference electrode - Optional Flow indicator - Default OPTIONS: - Regulator: yes ''R'', without it the letter is not written in - Measuring range: ''1'' for 0 to 1 mgCl2/l (0 –5 mgCl2/l adjustable) ''X''- on request - Reference: yes ''S'' , without it the letter is not written in TECHNICAL DATA General data : Ambient temperature: Relative humidity:...

Open the catalog to page 2

All Controlmatik catalogs and technical brochures

  1. MR 50 RC

    2 Pages

  2. MR 40 RC

    2 Pages

  3. MR 21 RC

    2 Pages

  4. MR 20 RC

    2 Pages

  5. M 30 RC

    2 Pages

  6. M 470 C PVC

    2 Pages

  7. M 3800

    2 Pages

  8. M 2103 C

    2 Pages

  9. M 4510 C

    2 Pages

  10. M 5265 C

    2 Pages

  11. automation

    1 Pages

  12. M 5700 C

    2 Pages

  13. M 1322

    2 Pages

  14. M 1122

    2 Pages

  15. M 1056 C

    2 Pages

  16. M 1036 C

    2 Pages

  17. M 20 RC

    2 Pages

  18. M 3610 C

    2 Pages

  19. M 3480 C

    2 Pages

  20. M 3100 C

    2 Pages

  21. M 3319 C

    2 Pages

  22. M 3531 C

    2 Pages

  23. M 300 C

    2 Pages

  24. M 200 C

    2 Pages

  25. M 20 C

    2 Pages

  26. M 40 C

    2 Pages

  27. M 50 C

    2 Pages

  28. M 5262 C

    2 Pages

  29. M 5600 C

    2 Pages

  30. M 3521 C

    2 Pages

  31. M 40 C

    2 Pages