Overview: The document provides technical specifications and applications for the MS module range, designed for monitoring, insulation, and power supply in engineering, industry, and marine applications. The modules are engineered to high standards and are ISO 9001 certified.
MS Module Range: The MS4S module acquires analog signals, processes them, and monitors them against four adjustable thresholds. It provides a 4-20 mA signal for duplication on an indicator or PLC input.
Applications: The modules are used for converting inputs into 4-20 mA signals, monitoring current and voltage, insulating signals, and providing power supplies.
Advantages: Single-channel modules allow for custom-made systems that can be installed on DIN rails. Plug-type terminal blocks facilitate rapid wiring and installation.
Specifications:
  • MSCTU: Converts 4-20 mA to 0-10 V with galvanic insulation. Input: 4-20 mA. Output: 0-10 V insulated. Insulation: 500 V. Accuracy: 1%. Service temperature: 0 to +60°C. Power supply: 24 Vdc.
  • MSI: Supplies insulated 24 Vdc from 20-60 Vdc input. Output: 6 channels, 24 Vdc ± 1% insulated. Insulation: 100 MOhms/500 Vdc. Service temperature: 0 to +60°C.
  • ModAlim: Supplies regulated 24 Vdc from 220 Vac input. Output: 24 Vdc ± 1%. Insulation: > 10 MOhms/500 Vdc. Service temperature: 0 to +60°C.
Additional Modules:
  • MSL: Converts voltage or thermocouple input into 4-20 mA signal. Accuracy: <1%. Service temperature: +5°C to +55°C.
  • MSIG: Provides galvanic insulation for 4-20 mA current loop. Insulation: 500 V with DC/DC, 1500V without DC/DC. Accuracy: 1%.
  • MSAU: Monitors 4-20 mA current and triggers alarms based on thresholds. Service temperature: +5°C to +55°C.
  • MSASU: Monitors 24 Volt voltage and triggers alarms if voltage is out of range. Service temperature: 0 to +60°C.
  • MSLA: Monitors electrovalve lines and triggers alarms in case of line breaks. Service temperature: 0 to +60°C.
See more

Catalog excerpts

Monitoring - Insulation - Power supply MS-1

Monitoring - Insulation - Powe Pbwflr Suwly WVrJc Zero adjuslmenl Wire section Z.Smrrr max I Function: converts a 4-20 mA signal into 0-1 □ V with galvanic insulation also supplies a current output without offset zero : □ - 20 mA or □ -1 mA with galvanic insulation with regard to the rnflnBl Hatli far '.lirrvn man I Function: supplies an insulated voltage of 24 Vdc from a continuous variable voltage from I Output: 6 channels, 24 Vdc ± 1 % insulated, I Function: supplies a voltage regulated in 24 Vdc from an alternative voltage of 220 Vac Engineered to uncompromising standards. Yours. Monitoring - Insulation - Power supply The MS module range is completed by the MS4S, realizing the acquisition of an ana- log signal and, after processing, monitoring this signal with regard to 4 adjustable thresholds associated to 4 relays with inverting contact. This module also supplies a 4-20 mA signal, insulated for duplication of the input on an indicator or for a possible PLC input. The MS module range allows, on one hand, to realize measuring and monitoring assemblies from elementary functions and, on the other hand, to realize insulation and power supply The MS modules are used in 4 application cases: • Conversion of Pt 100, thermocouples and voltage inputs into 4-20 mA signals. • Monitoring of current and voltage (exceeding of adjustable threshold or out of range] and of electrovalve or relay lines. • Power supplies. Using single channel modules allows to realize associations in order to make up ((custom- made)) systems likely to be installed on DIN rail nearest to the installations to be monitored. The plug type terminal blocks allow very rapid wiring and installation / removal. Engineered to uncompromising standards. Yours.

 Open the catalog to page 1
Monitoring - Insulation - Power supply MS-2

Monitoring - Insulation - Power Compensauon adjustment: ttiafmacouplG input Lftfigll ED be stripped brim Zero adjustment Sensor input Length to be stripped irmrr. I Function: converts a voltage or thermocouple input into 4 - 20 mA signal I Input: voltage, □ - 7 mV to □ -105 mV ranges I Load resistance : < [V powersupply -10] / 0,02 I Function: converts a Pt100 or PT1000 probe input into 4 - 20 mA signal I Input: Pt100 or Pt1000 probe, 2 or 3 wires I Load resistance : < [V powersupply -10]/ 0,02 Zero adjustment I Function: realizes the galvanic insulation of a I Insulation : 500 V with DC/DC,...

 Open the catalog to page 2

All CONTROLE MESURE REGULATION catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.