Type 6100/6200
2Pages

{{requestButtons}}

Catalog excerpts

Type 6100/6200 - 1

High Flow Capacity Volume Booster Rapid stroke capability in rugged aluminum or 316 stainless steel construction The ControlAir Type 6100/6200 volume booster is a 1:1 signal to output relay that is utilized in applications that require high forward flow and exhaust capacities. The Type 6100 is constructed of aluminum and the Type 6200 is constructed of 316 stainless steel. Typically they are used to increase throttling speed of large volume valve actuators. They are suitable for either diaphragm or piston actuators. A fixed deadband and adjustable bypass valve combine to allow small incremental downstream adjustment without opening the main booster valve. The bypass valve is used to adjust dynamic response to provide stable operation over a wide range of actuator sizes. Features • 1/4”, 1/2” or 3/4" NPT Porting • Aluminum or 316 Stainless Steel Construction • Integral Adjustable Bypass Valve Allows small incremental signal changes without opening the primary valve • High Flow Capacity For rapid actuator stroking • Soft Valve Seat Design Provides tight shutoff and eliminates leakage in steady state operation • High Temperature Operation Up to 200°F (93°C) • High Output Exhaust Vents (2) 1/4" NPT tapped exhaust (Type 6100 option) 1/2" NPT tapped exhaust (Type 6200 standard) • 2 1/4" NPT Gauge Ports • Balanced Supply Valve Minimizes the effect of supply pressure variation • Optional Negative Bias 4 psi (0.3 bar) negative bias of signal pressure to 'zero' I/P's Flow, scfm (nl/min) Supply Pressure: 100 psig (7.9 bar) Cv: 4.5 Flow, scfm (nl/min) Output Pressure psig (bar) Supply Pressure: 100 psig (7.9 bar) Cv: 2 Regulated Pressure vs Flow: 3/4” Type 6100/6200 Output Pressure psig (bar) Output Pressure psig (bar) Supply Pressure: 100 psig (7.9 bar) Cv: 5

Open the catalog to page 1
Type 6100/6200 - 2

Type 6100/6200 High Flow Capacity Volume Booster Dimensions Specifications Signal/Output Ratio Supply Pressure Signal Pressure Temperature Limits Low Temperature Option Maximum Flow Coefficients (Cv) Exhaust Capacity 5 psig (0.35 bar) above 20 psig (1.38 bar) setpoint Output Accuracy Sensitivity Deadband Suppy Pressure Effect Signal Port Supply/Output Port Exhaust Port _ 250 psig (17.0 bar) Maximum 150 psig (10.0 bar) Maximum -40 to 200 °F (-40 to 93 °C) -62 to 194 °F (-52 to 90 °C) 6100 6200 Port Forward Exhaust Exhaust 1.0% of 100 psi output span 1" H2O (2.54 cm) Under 0.2 psig (.01 bar)_...

Open the catalog to page 2

All ControlAir catalogs and technical brochures

  1. Type 1230

    4 Pages

  2. Type 1227

    4 Pages

  3. Type 7200BP

    2 Pages

  4. I/PAC

    4 Pages

  5. Type 590X

    2 Pages

  6. Type-700BP

    2 Pages

  7. Type 100M

    2 Pages

Archived catalogs