Catalog excerpts
Type 595XP Explosion-Proof I/P Transducer High level of regulation accuracy and repeatability for the operation of actuated valves The Type-595XP Explosionproof I/P (current to pressure) transducer converts a 4–20mA electrical current signal to a proportionally linear pneumatic output. The unique conversion technology utilizing open loop control provides a high level of accuracy and repeatability for the operation of actuated valves. A low mass control circuit provides consistent output in high vibration applications. This compact unit is housed in an explosion proof enclosure that is designed for pipe, bracket or direct manifold mounting. This explosion-proof and intrinsically safe field device is available with an integral volume booster or as a low-flow signal converter that directly mounts to a pneumatic valve positioner. The Type-595XP has worldwide agency approvals for use in hazardous areas. •Compact Design Small size and low weight •Worldwide Safety Approvals Factory Mutual (FM), Canadian Standards Association (CSA) and ATEX •Vibration and Position Insensitive Unit can be mounted in any plane and is stable in high vibration environments Minimize loop load
Open the catalog to page 1Type 595XP Explosion-Proof I/P Transducer D I M E N S I O N S Ported with Flow Booster (P) Manifold Mount without Flow Booster (M) Ported without Flow Booster (N) Optional 2" Bracket PROFILE SHEET FOR WALL MOUNTING Ø.34[8.6] Drawing downloads available at www.controlair.com
Open the catalog to page 23-15 psig 3-27 psig 6-30 psig Temperature Limits Electrical Connections Mounting Materials Weight Mounting Orientation Effect Port Sizes Loop Load 75% average - 95% short time non-condensing Temperature Effect Relative Humidity Vibration Effect Flow Capacity M & N Connection (without Flow Booster) Supply Pressure Note: Supply pressure must be a minimum of 5 psig (0.3 BAR) above maximum output P Connection (with Flow Booster) <±0.3% of span; <±0.15% of span typical <±0.5% / 90 degree change <.3% / 1.5 (0.10 BAR) psig change NEMA 4X (IP 65) Pneumatic: 1/4" NPT (P & N versions); 1/16" manifold...
Open the catalog to page 3Hazardous Area Factory Mutual (FM) & Canadian Standards Association (CSA) *See energy limiting parameters. Refer to Instruction Manual 441-622-099. Use this coding system to order Input Signal Output Pressure without Booster without Booster with Booster 2" Pipe Bracket Mounting Kit: P/N 448-542-016 ControlAir, Inc. products are warranted to be free from defects in materials and workmanship for a period of eigh- teen months from the date of sale, provided said products are used according to ControlAir, Inc. recommended usages. ControlAir, Inc.'s liability is limited to the repair, pur- chase...
Open the catalog to page 4All ControlAir catalogs and technical brochures
-
Type 6100/6200
2 Pages
-
Type 1230
4 Pages
-
Type 1227
4 Pages
-
Type 7200BP
2 Pages
-
Short Form Catalogue
8 Pages
-
Type 200 Precision Air Relay
2 Pages
-
I/PAC
4 Pages
-
Type 6000 - Volume Booster
2 Pages
-
Type 250 - Lock-Up Air Relay
2 Pages
-
Natural Gas brochure
2 Pages
-
Rolling Diaphragm Air Cylinders
12 Pages
-
Type 590X
2 Pages
-
Type-700BP
2 Pages
-
Type 100M
2 Pages
-
Type-6000 Volume Booster
2 Pages
-
Type-250 Lock-Up Air Relay
2 Pages
-
Type 650 Positive Bias Relay
2 Pages
-
Type 600 Volume Booster
2 Pages
Archived catalogs
-
Diaphragm Air Cylinders
12 Pages