Overview: The Type 500X Electropneumatic Transducer by ControlAir is designed to convert electrical signals (current or voltage) into proportional pneumatic output pressure. It is suitable for applications requiring high reliability and repeatability at a low cost, with optional NEMA 4X (IP65) for outdoor use.
Applications: Commonly used in industries such as petrochemical, HVAC, energy management, textile, paper, food, and drug for controlling valve actuators, pneumatic valve positioners, dampers, louvers, relays, air cylinders, clutches, and brakes.
Features: Key features include low cost, integral volume booster, compact size, low air consumption, field reversibility, flexible zero and span adjustments, standard process inputs, and split ranging capabilities.
Specifications: The Type 500X is available in two versions: a lower range model for 3 to 15 psig output and an extended range model for up to 120 psig output. It operates on a force balance principle with a coil and magnet system. The unit is field reversible and can be recalibrated for split ranging.
Installation and Safety: The transducer can be mounted via pipe, panel, or bracket. It is Factory Mutual approved as intrinsically safe and nonincendive for various classes and divisions. Installation should follow ControlAir's guidelines for safety and performance.
Performance: The transducer offers high repeatability (<0.5% of span), low hysteresis (<1.0% of span), and quick response time (typically <0.25 sec for 3-15 psig units). It consumes minimal air and supports a wide operating temperature range (-20°F to +140°F).
Ordering Information: Various models are available with different input and output ranges, impedance, and optional accessories like DIN connectors, NEMA 4X enclosures, BSP porting, and pressure gauges.
Warranty: ControlAir provides an 18-month warranty against defects in materials and workmanship, with liability limited to repair, refund, or replacement.
See more

Catalog excerpts

Type 500 - Electropneumatic Transducer (I/P, E/P)-1

Electropneumatic Transducer (I/P, E/P) Economical and reliable electrical conversion to pressure The ControlAir Type 500X converts a current or voltage input signal to a linearly proportional pneumatic output pressure. This versatile instrument is designed for control applications that require a high degree of reliability and repeatability at an economical cost. Optional NEMA 4X (IP65) version allows for splashdown and outdoor installation. Typically, these units are used for applications that require the operation of valve actuators, pneumatic valve positioners, damper and louver actuators, final control elements, relays, air cylinders, web tensioners, clutches, and brakes. Industries that utilize the Type 500X include Petrochemical, HVAC, Energy Management, Textile, Paper, Paper Converting, Food and Drug Features •Low Cost • Integral Volume Booster •Compact Size •Low Air Consumption • Field Reversible •Flexible Zero & Span Adjustments •Standard Process Inputs •Split Ranging

 Open the catalog to page 1
Type 500 - Electropneumatic Transducer (I/P, E/P)-2

The Type 500X is available in two different versions. The lower range model is designed for standard process control applications which typically utilize a 3 to 15 psig output. The extended range unit provides up to 120 psig output for higher pressure industrial pneumatic and process control system requirements. Principle of Operation The Type 500X Transducer is a force balance device in which a coil is suspended in the field of a magnet by a flexure. Current flowing through the coil generates axial movement of the coil and flexure. The flexure moves towards the nozzle and creates back pressure...

 Open the catalog to page 2
Type 500 - Electropneumatic Transducer (I/P, E/P)-3

Compact Size Field Reversible Standard Process Inputs Flexible Zero & Span Adjustments Integral Volume Booster Split Ranging Specifications LOW OUTPUT RANGE (UP TO 30 PSIG) HIGH OUTPUT RANGE (UP TO 120 PSIG) Min./Max. Supply Pressure Minimum - 3 psig (.21 BAR) Above maximum output Maximum - 100 psig (7 BAR) Minimum - 5 psig (0.35 BAR) above maximum output Maximum - 150 psig (10.5 BAR) Supply Pressure Sensitivity <± 0.1% of span per psig (<± 0.15% of span per 0.1 BAR) Terminal Based Linearity Response Time Dependent on pressure range - typically less than 0.25 sec for 3-15 psig units Flow Rate...

 Open the catalog to page 3
Type 500 - Electropneumatic Transducer (I/P, E/P)-4

Dimensional Drawings (2) #10-32 UNF-2A x .38 DP. Mounting Holes (Shown with Bracket Screws Installed) Ordering Information Type 500X Type 500X I/P Transducers Part Number (2) #18 GA. Wire Leads, 18" Long. Black = Positive White = Negative Type 500X E/P Transducers Part Number 1.13 28.7 Diameter *Output shown is as calibrated at the factory. Large span adjustment capability allows recalibration to achieve output ranges from 3-35 psig (0.2-2.4 BAR) with 2-60 psig unit to 3-145 psig (0.2-10 BAR) with 2-120 psig unit. 2.88 73.1 Removable Mounting Bracket .21 .53 Diameter MNTG. Holes Options/Accessories:...

 Open the catalog to page 4

All ControlAir catalogs and technical brochures

  1. Type 1230

    4  Pages

  2. Type 1227

    4  Pages

  3. Type 7200BP

    2  Pages

  4. I/PAC

    4  Pages

  5. Type 590X

    2  Pages

  6. Type-700BP

    2  Pages

  7. Type 100M

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.