I/PAC - 1

I/PAC Integrated Process Air Control Field rugged, quick mount I/P - airset assemblies Explosion-proof field mounted I/P transducers from ControlAir are now offered as an integrated package that comes preassembled with a filter regulator and pressure gauge. Users can choose from different versions of either the Type-950XP or Type-595XP I/P combined with the Type-330 filter regulator. The package is bracketed to mount on a 2" pipe as well as directly onto valve yokes or other devices that utilize 2.25" bolt spacing. Integrated units carry all agency hazardous area approvals from FM, CSA and ATEX. •Seamless Replacements For existing automated control valves in the field •Convenient Bracketing Allows direct or 2" pipe mounting Units come preassembled with filter regulator and pressure gauge •Explosion-proof and Intrinsically Safe Approvals from FM, CSA and ATEX •Vibration and Position Insensitive •Compact Design Installs where others won’t

Open the catalog to page 1
I/PAC - 2

Integrated Process Air Control Direct Pipe Mount Yoke Mount or Offset Pipe Mount Direct Pipe Mount Drawing downloads available at www.controlair.com Yoke Mount or Offset Pipe Mount

Open the catalog to page 2
I/PAC - 3

3-15 psig 3-27 psig 6-30 psig Supply Pressure Note: Supply pressure must be a minimum of 5 psig (0.3 BAR) above maximum output Flow Capacity <±0.5% of span <±0.5% of span <±0.1% of span <±0.10 % of span (±0.25 with field-selectable option) <±0.3% of span; <±0.15% of span typical <±0.5% / 90 degree change <.3% / 1.5 (0.10 BAR) psig change Less than ±1.0% of span under the following conditions: 5-15Hz @ 0.8 inches constant displacement; 15-500Hz @ 10g’s Mounting Orientation Effect Electrical Connections Materials 0.10 % of span (±0.25 with field-selectable option) Linearity (Independent) 0.10...

Open the catalog to page 3
I/PAC - 4

I/PAC Hazardous Area Classifications Type 950XP/Type 330 Combination Factory Mutual (FM) & Canadian Standards Association (CSA) Approval Intrinsic Safety Class I, Division 1, Groups C & D Class II, Division 1, Groups E, F, & G Class III, Division 1; Fibers Explosion-Proof Class I, Divisions 1 & 2, Groups B, C & D Class II & III, Division 1, Groups E, F, & G Entity Parameters Vmax = 30 Vdc Imax = 125 mA Pi = 0.7 W Ci = 0 nF Li = 0 mH ——— Temperature Code Suitable for use with methane or natural gas supply pressure media when ordered with tapped exhaust and factory sealed conduit assembly...

Open the catalog to page 4

All ControlAir catalogs and technical brochures

  1. Type 1230

    4 Pages

  2. Type 1227

    4 Pages

  3. Type 7200BP

    2 Pages

  4. Type 590X

    2 Pages

  5. Type-700BP

    2 Pages

  6. Type 100M

    2 Pages

Archived catalogs