COMPALARM C2C ALARM ANNUNCIATOR GENERAL ETHERNET INTERFACE The C2C alarm system has been designed to join the maximum possible easiness of operation together with an high level of reliability. Allow the supervision of 12 alarm inputs from configurable contacts (NO,NC). The flush-mount 96x96mm housing combines both the microprocessor logic and alarms display, obtained through LEDs. It is possible to expand with serial and Ethernet communication. MAIN FEATURES • Flush mount housing, 96x96mm • 12 LED for alarms display • 3 keys (ACK, RESET, TEST) • Easy printing alarm legend • Configuring alarm inputs for use with NO or NC field contacts • Selectable alarm sequence by dip-switch • Integral audible alarms • First-out function • Two output relays (common and aubible) • Remote keys • Serial and ethernet communication EXPANSION The option units are designed and developed to enhance the functions of connectivity. The 485 option implements the isolated RS485 serial interface. The ETH option implements the ETHERNET interface. KEYBOARD FUNCTIONS ACK key-is used to silence the alarm and change the state of the associated alarm LED in accordance with the selected ISA sequence. RESET key-is used to return the alarm to the normal off state once the input has returned to the normal condition. TEST key-is used to test the LED assemblies by illuminating them in a steady state for as long as the pushbutton is pressed. DIP-SWITCHES FUNCTIONS Dip-switch up-is used to configure alarm inputs 1÷8 for use with NO or NC field contacts. Dip -switch low (1÷4)-is used to configure alarm inputs 9÷12 for use with NO or NC field contacts. Dip -switch low (5)-is used to enable internal audible alarms. Dip -switch low (6÷8)-is used to select the alarm sequence. RELAYS OUTPUTS FUNCTIONS “R1” output is suitable for alarms cumulative, this output will be activated at normal condition. After an alarm event this contact can be re-enabled only with RESET key, only for sequences that require this key. “R2” output is for audible device. Activates on alarm and remains active until the acknowledge key has been pressed. The contact state of both relays can be programmed to NC or NO using serial or Ethernet communication. WIRING DIAGRAM INPUT CONTACTS INPUT CONTACTS COMPALARM INPUT CONTACTS TEST LAMPS TEST LAMPS PUSH BUTTONS PUSH BUTTONS TEST LAMPS PUSH BUTTONS

Open the catalog to page 1
COMPALARM C2C - 2

COMPALARM C2C ALARM ANNUNCIATOR TECHNICAL CHARACTERISTICS AUXILIARY SUPPLY Rated voltage Power consumption ALARMS/REMOTE KEYS INPUTS Voltage 24 Vac/dc - 48 Vac/dc - 115 Vac/dc - 230 Vac/dc ALARM INPUTS Number of inputs REMOTE KEYS Number of remote keys OUTPUT RELAYS Number of outputs 2 (Alarm comulative, audible device) RS485 SERIAL INTERFACE Baud-rate Screw (removable) ETHERNET INTERFACE Network Interface Compatibility Protocol RJ45 10BASE-T or 100BASETX(auto-sensing) Ethernet: Version 2.0/IEEE802.3 TCP/IP,SMTP,FTP HTTP Terminal type HOUSING Version AMBIENT CONDITIONS Operating temperature...

Open the catalog to page 2

All Contrel elettronica catalogs and technical brochures

  1. MR-R8

    8 Pages

  2. EMS-D6

    8 Pages

  3. RI-R45

    8 Pages

  4. TCS-A5

    3 Pages

  5. TCS

    4 Pages

  6. HRI-R40

    3 Pages

  7. ELRC-1

    2 Pages

  8. ELR - 7

    2 Pages

  9. ELR-3F

    2 Pages

  10. ELR-3E

    2 Pages

  11. ELR-3C

    2 Pages

  12. PR-5

    1 Pages

  13. RSR-72

    3 Pages

  14. RI-R44

    2 Pages

  15. TCC / TCCN

    14 Pages

  16. EMS-96

    3 Pages

  17. EMM-4L

    2 Pages

  18. EMM-D4h

    2 Pages

  19. EMM-4d2c

    2 Pages

  20. EML-16

    1 Pages

  21. EMI-10L

    1 Pages

  22. EMC-3B

    1 Pages

  23. EMA-D9

    2 Pages

  24. EMA-90N

    2 Pages

  25. EMA-11

    2 Pages

  26. ELR-1D

    2 Pages

  27. ELM

    2 Pages

  28. MDVH - MDDH

    4 Pages

  29. DVH - DDH

    5 Pages

  30. GW-12

    3 Pages

  31. COMPALARM A

    5 Pages

  32. COMPALARM AP

    4 Pages