Alarm systems and temperature monitor device
36Pages

{{requestButtons}}

Catalog excerpts

Alarm systems and temperature monitor device - 2

PANEL SIGNALING SQ COMPALARM A RACK ALARM ANNUNCIATOR COMPALARM CM MECHANICAL ALARM ANNUNCIATOR COMPALARM AP ALARM ANNUNCIATOR COMPALARM C0/sq ALARM VISUALIZATION 48 x 48 mm COMPALARM C2/sq ALARM VISUALIZATION 96 x 96 mm COMPALARM C3/sq ALARM VISUALIZATION 72 x 144 mm COMPALARM C2C ALARM ANNUNCIATOR WITH MODBUS COMMUNICATION COMPALARM GW ALARM GSM MODULE COMMUNICATION COMPALARM D2 - D2m DISPLAY ALARM ANNUNCIATOR WITH MODBUS COMMUNICATION TEMPERATURE MONITOR DEVICES CTT

Open the catalog to page 2
Alarm systems and temperature monitor device - 4

COMPALARM A RACK ALARM ANNUNCIATOR GENERAL The system is composed by: • Alarm card • Power supply and flashing card • Relay card • Timing card • Card holder unit • Power transformers and Dc/Dc converters • Signalling cells, SQ type (with LED on request) It’s available in 2 different executions: • The first one being supplied with its various componentsunassembled, but fitted with their corresponding wiring terminals. • The second is being supplied as a prewired solution in a flush mounting rack. The first solution is the most versatile either for assembling or displaying. As far as its...

Open the catalog to page 4
Alarm systems and temperature monitor device - 5

RACK ALARM ANNUNCIATOR SEQUENCE TABLE contrel ALARM SYSTEMS COMPALARM | TEMPERATURE MONITOR DEVICES CTT I

Open the catalog to page 5
Alarm systems and temperature monitor device - 6

COMPALARM A RACK ALARM ANNUNCIATOR ALARM CARD RELÈ CARD 6 repeat relays without memory 4 repeat relays without memory 6 repeat relays with memory 4 repeat relays with memory 6 repeat relays with memory and reflash pulse feature 4 repeat relays with memory and reflash pulse feature With 100 x 190 mm size, it is capable of governing up to 6 alarm points (4-alarm point card is also available). This card is subdivided in 6 or 4 different sections, in order to allow them a totally independent operation, to prevent that good working of more than one alarm point can be affected by failure of one...

Open the catalog to page 6
Alarm systems and temperature monitor device - 7

COMPALARM A RACK ALARM ANNUNCIATOR RELAY CARD MODELS Card holder 4+1 locations Card holder 7+1 locations Card holder 11+1 locations\ Card holder 15+1 locations Card holder 4 with interconnection card Card holder 7 with interconnection card Card holder 11 with interconnection card Card holder 15 with interconnection card They are available for 4-7-11-15 card locations, in basic versions. They have the same dimensions as those given in table here below. These locations can be combined so as to reach the desired number of card locations (by using the interconnection card). VERSIONS PRE-WIRED...

Open the catalog to page 7
Alarm systems and temperature monitor device - 8

COMPALARM A RACK ALARM ANNUNCIATOR TRANSFORMERS When the provided auxiliary power supply is different from 24 VAC or 24 VDC, you cannot power the alarm directly on the card flasher 2ft but you have to use upstream power transformers series TR or converters DC series. If the auxiliary power supply is 110 VAC or 230 VAC or 400 VAC are used transformers TR series with the secondary 24 VAC which then feed then the card flasher 2FT VAC. The transformers are available in various capacities from 50 VA to 300 VA. If the auxiliary power supply is 48 VDC, 110 VDC or 220 VDC are used DC converters...

Open the catalog to page 8
Alarm systems and temperature monitor device - 9

PANEL SIGNALING SQ GENERAL The SQ type basic signaling cells are available in the 30 x 30 mm versions. From the cells, it is possible to obtain ohter four types (A-B-C-D). The 30 x 30 mm dimension has been chosen, since one may reach the DIN 72 x 72 dimension with a possible combination of 4 cells. All above to allow its installation with other systems built, according with DIN standard. The SQ series are prepared to accept incandescent lamps or MULTILED, with BAS9 fixing and a power of 1W. It is possible to reach up to 200 cells, with the COMPALARM A. The lamp substitution is being made...

Open the catalog to page 9
Alarm systems and temperature monitor device - 10

• The number of visualisation cells is equal to the result of multiplying the number of rows by the number of columns. • Lthe drill dimensions are C (height). • The tolerance is of 0,1 mm. B Example: 5 ROWS BY 7 COLUMNS VISUALISATION PANEL • The total number of cells would be 35. • The external dimensions would be 162 mm of height by 222 mm of widht. • The drill dimension would be 155 mm height by 215 mm of widht. Writable area Type of windows Dimensions 8 | ALAR C O M PA TEM E MO VICES Writable area M SY STE M S 25x25 L A R M |55x25 P E R AT U R25x55N IT O R D E55

Open the catalog to page 10
Alarm systems and temperature monitor device - 11

COMPALARM AP ALARM ANNUNCIATOR GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 30 x 30 mm cells, fitted with ultra bright white LED’s, achieving a low power consumption and a lamp maintenance free operation. The interconnecting possibility allows to design other supervision alarm systems with many extensions. The alarm systems type COMPALARM AP has been conceived with its very reduced dimensions, but maintaining the characteristics of the COMPALARM A system. This system has...

Open the catalog to page 11
Alarm systems and temperature monitor device - 12

COMPALARM AP ALARM ANNUNCIATOR TECHNICAL CHARACTERISTICS AUXILIARY SUPPLY Rated voltage Frequency Power consumption CHANNEL INPUTS Number of inputs Voltage inputs 12 (standard) or more 24 VAC/DC - 48 VAC/DC - 115 VDC Consumption (each input) Window illumination LED color Hi-efficiency white LED Red, yellow, green, blue, white, orange OUTPUTS Number of outputs AMBIENT CONDITIONS Operating temperature Storage temperature Relative humidity HOUSING Version Flush mount Degree of protection Weight CERTIFICATIONS AND COMPLIANCE Reference standards DESCRIPTION Power supply 24 VAC/DC – Voltage...

Open the catalog to page 12
Alarm systems and temperature monitor device - 13

COMPALARM AP ALARM ANNUNCIATOR DIMENSIONS AND PANEL CUT OUT AP48 + pushbuttons AP48 AP36 AP24 AP12 132 FRONT PANEL 1 - For removing the lens groups, it’s sufficient to insert the screwdriver tip into the frame’s grove and lever up slightly, as indicated. 2 - To separate the parts of the group, press on the rear of the plate, enlarging slightly the frame, as indicated on the left image, or levering up with a small screwdriver. Window colours: Blue - Green - Red - Yellow - White - Orange Printing plate Fixing clips Lens fixing frame For printing, it’s possible to print the number 3 part, or...

Open the catalog to page 13

All Contrel elettronica catalogs and technical brochures

  1. MR-R8

    8 Pages

  2. EMS-D6

    8 Pages

  3. RI-R45

    8 Pages

  4. TCS-A5

    3 Pages

  5. TCS

    4 Pages

  6. HRI-R40

    3 Pages

  7. ELRC-1

    2 Pages

  8. ELR - 7

    2 Pages

  9. ELR-3F

    2 Pages

  10. ELR-3E

    2 Pages

  11. ELR-3C

    2 Pages

  12. PR-5

    1 Pages

  13. RSR-72

    3 Pages

  14. RI-R44

    2 Pages

  15. TCC / TCCN

    14 Pages

  16. EMS-96

    3 Pages

  17. EMM-4L

    2 Pages

  18. EMM-D4h

    2 Pages

  19. EMM-4d2c

    2 Pages

  20. EML-16

    1 Pages

  21. EMI-10L

    1 Pages

  22. EMC-3B

    1 Pages

  23. EMA-D9

    2 Pages

  24. EMA-90N

    2 Pages

  25. EMA-11

    2 Pages

  26. ELR-1D

    2 Pages

  27. ELM

    2 Pages

  28. MDVH - MDDH

    4 Pages

  29. DVH - DDH

    5 Pages

  30. GW-12

    3 Pages

  31. COMPALARM A

    5 Pages

  32. COMPALARM AP

    4 Pages