Model 515
4Pages

{{requestButtons}}

Catalog excerpts

Model 515 - 1

Model 515 Application BF01 Dual Stage Batch/Flow Controller for Volumetric Frequency Flowmeters The 515 BF01 application is a batching flow controller for delivery of preset quantities at preset flowrates using a volumetric frequency input. Batch control can operate in preset or on-off modes, while flow control can be set to local (manual) or PI loop mode. The total and flowrate are derived from accurately measured frequency and the number of received pulses. Tailored for volumetric frequency flow input Single or Dual stage control Preset or manual On-Off modes Easy access to batch and flow rate presets No-flow, leakage and overflow error detection Remote RUN/STOP/RESET Allows for permissive with prompt Uses PI Loop Control Allows for non-linear correction Storage of 1000 transactions with time and date stamp Selection of second language and user tags Selectable protocols on serial ports including Modbus RTU and Printer output Backlit display with LCD backup This application provides the operator with clear local readout including flowrate deviation and can be controlled via communications in more automated systems. There is quick access to commonly used preset values directly from the front panel if access has been authorized. volume = pulses / k-factor volume flow = frequency / k-factor Automatic overrun compensation calculates the new valve closure point to ensure correct delivery by averaging the overrun amount from the last three complete batches. The overrun compensation value is valid for a new preset value provided the stored overrun is less than 20% of the new preset. The PI control of the process flow is via a 4-20mA proportional valve or pump controller. It has integral windup protection, a deadband, output hold and ramp time that can be programmed to reduce wear on valves and actuators and provide for bumpless operation. Frequency Input Proportional Control Device Volumetric Flowmeter On-Off Valve Example Batch/Flow Configuration

Open the catalog to page 1
Model 515 - 2

Displayed Information The front panel display shows the current values of the input variables and the results of the calculations. A list of the variables for this application and their type (total or rate) is shown at the end of this document. The instrument can be supplied with a real-time clock for storage of up to 1000 transactions with time and date stamps. Instrument parameters including units of measurement can be programmed in the field, according to the user access levels assigned to parameters by the distributor. All set-up parameters, totals and logged data are stored in...

Open the catalog to page 2
Model 515 - 3

2 relays plus 2 optional relays -20 °C to +60 °C (conformal coating) +5 °C to +40 °C (no coating) 0 to 95% non condensing (conformal coating) 5% to 85% non condensing (no coating) Operating Environment Temperature Humidity Power Supply Consumption Protection Dimensions (panel option) Sealed to IP65 (Nema 4X) when panel mounted 147 mm (5.8") width 74 mm (2.9") height 167 mm (6.6") depth Display Type Digits Characters LCD Backup Update Rate Backlit LCD with 7-digit numeric display and 11-character alphanumeric display 15.5 mm (0.6") high 6 mm (0.24") high Last data visible for 15 min after...

Open the catalog to page 3
Model 515 - 4

Ordering Information Product Codes Model Supplementary Code Field mount enclosure (NEMA 4X / IP66) Explosion proof Ex d (IECEx/ATEX), metric glands (5 specifies heater) Panel mount enclosure Explosion proof Ex d (CSA), NPT glands (6 specifies heater) 0 1 4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232 (DB9) and RS485 communication ports Output Options 4 logic inputs, 1 isolated output, 2 relays (only relay type 1 is available), RS232 (DB9) communication port 4 logic inputs, 2 isolated outputs, 4 relays, real-time clock data logging, RS232 (DB9) and...

Open the catalog to page 4

All Contrec Ltd catalogs and technical brochures