Catalog excerpts
SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE 5505 WEST 123RD STREET • SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VSNG6 - SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE CONTINENTAL HYDRAULICS
Open the catalog to page 1VSNG6 - SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE Direct acting, subplate mounted directional control valve, with mounting surface according to NFPA D03 ISO 4401-03 (CETOP RP 121H) standards suitable for mini-power packs and mobile and agricultural applications. The valve body is made with high strength iron castings with wide internal passages in order to minimize the flow pressure drop. TYPICAL PERFORMANCE SPECIFICATIONS MAXIMUM OPERATING PRESSURE: MAXIMUM FLOW RATE MOUNTING SURFACE The valve can be supplied for valve...
Open the catalog to page 2MECHANICAL OMIT IF NOT REQUIRED DESIGN LETTER Single Operator 2 Position Spring Offset CORE TUBE Single Solenoid ‘B’ Port End. Available Only with Function 1,5 and 9. DC Tube Without Coils. See Note. 2 Dual Operator 2 Position Detented (No Spring) VSNG6 - SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE IDENTIFICATION CODE 3 Dual Operator 3 Position Spring Centered 5 Single Operator 2 Position Spring Centered TYPICAL ORDERING CODE: NOTE: Coil supplied separately. See coils section on page 6. Single Operator 2 Position 3 Way Spring Offset SPOOLS NAME CENTER POSITION FUNCTION MATCHING...
Open the catalog to page 3VSNG6 - SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE PERFORMANCE CURVE DC SOLENOID VALVE NOTES: 1. The values indicated in the graphs are relevant to the standard solenoid valve, with D24K1 coils. 2. Valve performance was tested in a four way circuit (full loop). Performances may be reduced from that shown when used in a three-way circuit (half circuit), i.e. A or B port plugged. 3. The values have been obtained according to ISO 6403 norm with solenoids at rated temperature and supplied with voltage equal to 90% of the nominal voltage. The value have been obtained with...
Open the catalog to page 4Solenoid Position For Reverse Operator Locking Ring With Boot Protected Manual Override Connector Removal Space VSNG6 - SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE OVERALL AND MOUNTING DIMENSIONS Locking Ring With Boot Protected Manual Override Mounting Surface With Sealing Rings: 4 pcs. AS568-012 Shore A Coil Removal Space KNOB MANUAL OVERRIDE / STROKE LIMITER ACCESSORY See on page 8. SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM
Open the catalog to page 5VSNG6 - SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE COILS ORDERING CODE DC ORDERING CODE - RECTIFIED Lead Wires (1mt Length) - IP67 K7 SUPPLY VOLTAGE FLUCUATION MAXIMUM SWITCH ON FREQUENCY DUTY CYCLE Coil Insulation CURRENT CONSUMPTION RESISTANCE AT 68°F [Ω] (±1%) D12 The coils are fastened to the tube by a threaded nut and can be rotated 360°. ‘R’ rectified coils must be used when the valve is fed with AC power supply subsequently rectified by means of rectifier bridge. Continental Hydraulics offers DIN43650 connectors with a built-in rectifier bridge. Refer to VEA-6FR on page...
Open the catalog to page 6FLUIDS All pressure drops shown on these data pages are based on 170 SUS fluid viscosity and 0.87 specific gravity. For any other specific gravity (G1) the pressure drop (∆P) will be approx. ∆P1 = ∆P (G1/G). See the chart for other viscosities. FLUID VISCOSITIES Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type (phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical department. Using fluids at temperatures higher than 176 °F causes a...
Open the catalog to page 7VSNG6 - SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE Black - With Built-in Graetz Bridge Rectifier Suitable for A and B Solenoids KNOB MANUAL OVERRIDE / STROKE LIMITER This dual-purpose device is an adjustable stop that may be utilized to position and hold the spool shifted. It may also be used to limit spool travel and regulate flow to the discharge port. This device is ordered separately with the following code: VMA-2A-A BOLT/STUD KITS BD03-125 Valve only NOTE: 1. Bolt Kit Consists Of: 4 pcs. 10-24NC Fasteners 4 pcs. #10 Lock Washer 2. Stud Kit Consists Of: 4 pcs. 10-24NC...
Open the catalog to page 8VSNG6 - SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM
Open the catalog to page 9VSNG6 - SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE ABOUT CONTINENTAL HYDRAULICS Rugged, durable, high-performance, efficient—the reason Continental Hydraulics’ products are used in some of the most challenging applications across the globe. With a commitment to quality customer support and innovative engineering, Continental’s pumps, valves, power units, mobile and custom products deliver what the markets demand. Continental has been serving the food production, brick and block, wood products, automotive and machine tool industries since 1962. Learn how our products survive...
Open the catalog to page 10All CONTINENTAL HYDRAULICS catalogs and technical brochures
-
C03 MSV-P*
4 Pages
-
F0*MSV-BV
6 Pages
-
JIC Style
76 Pages
-
Motion Control Solutions
26 Pages
-
VED03M
12 Pages
-
VSD03M*-S
12 Pages
-
PVER
10 Pages
-
LPV series
20 Pages
-
VED*HL KD2
30 Pages
-
VED03MX
10 Pages
-
VSD*S
34 Pages
-
LPV SERIES AXIAL PISTON PUMPS
20 Pages
-
PVX
52 Pages
-
PVER VANE PUMPS
10 Pages
-
VSD03M
12 Pages
-
VS6M
8 Pages
-
VSD05M
12 Pages
-
VSNG10
8 Pages
-
VAD03M-VPD03M- VMD03M
10 Pages
-
VSD*HL-*-KD2
28 Pages
-
VSD*M-VPD*M
26 Pages
-
Power Unit
146 Pages
-
Piston Pump Catalog
51 Pages
-
Vane Pump Catalog
58 Pages
-
Directional Control Valves
98 Pages
-
Modular Stack Valves
79 Pages
Archived catalogs
-
NFPA/JIC Catalog
76 Pages
-
L-Shaped Catalog
80 Pages
-
WASH DOWN OPTION VALVES
4 Pages
-
PowrFlow™ PVX Vane Pumps
52 Pages
-
PowrFlow™ PVR Series Vane Pumps
65 Pages
-
Power Units
155 Pages
-
Axial Piston Pumps
51 Pages