PILOT OPERATED DIRECTIONAL VALVES 5505 WEST 123RD STREET • SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VSD*M-VPD*M - PILOT OPERATED DIRECTIONAL VALVES CONTINENTAL HYDRAULICS

Open the catalog to page 1
VSD*M-VPD*M - 2

VSD*M-VPD*M - PILOT OPERATED DIRECTIONAL VALVES PILOT OPERATED DIRECTIONAL VALVES The VSD*M and VPD*M pilot operated directional control valves are available with either electric solenoid or hydraulic actuation of the main spool. Available in 5 standard NFPA and ISO patterns, these pilot operated valves are used in applications requiring high flow rates. The valves are available in both 2 or 3 position and various spool flow patterns. On VSD*M valves, the configuration for internal or external pilot/drains can be easily changed in the field. Also available to improve consistent cycling of...

Open the catalog to page 2
VSD*M-VPD*M - 3

IDENTIFICATION CODE - SOLENOID OPERATED Solenoid Operated External Pilot External Drain Internal Pilot Internal Drain Internal Pilot External Drain External Pilot Internal Drain MECHANICAL OPTIONS OMIT IF NOT REQUIRED CONNECTION BOX OPTIONS OMIT IF NOT REQUIRED PILOT / DRAIN DESIGN LETTER SOLENOIDS - See the codes on page 20) ELECTRICAL OPTION OMIT Plug-in terminal solenoids or lead wires Connection box with terminal posts and lights INTERNAL PILOT OPTIONS AVAILABLE ONLY WITH PILOT/DRAIN 1 AND 3 (OMIT IF NOT REQUIRED) Reverse Mode Sol. ‘A’ Supplied Single Operator 2 Position Spring Offset...

Open the catalog to page 3
VSD*M-VPD*M - 4

VSD*M-VPD*M - PILOT OPERATED DIRECTIONAL VALVES IDENTIFICATION CODE - HYDRAULIC OPERATED DESIGN LETTER Hydraulic Operated MECHANICAL OPTIONS OMIT IF NOT REQUIRED Reverse Mode Stroke Adjustment On Main Stage Stroke Adjustment On A Port End Stroke Adjustment On B Port End X Port Is Actuator B Y Port Is Actuator A Adjustable Pilot Chokes Single Operator 2 Position Spring Offset TYPICAL ORDERING CODE: Dual Operator 3 Position Spring Centered Single Operator 2 Position Spring Centered WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

Open the catalog to page 4
VSD*M-VPD*M - 5

FUNCTION MATCHING P &  A blocked, B →T P & A blocked, B →T or all blocked P blocked, A →T and B →T P blocked, A →T or B →T P blocked, A →T and B→T restricted P blocked, A →T or B →T restricted P &  B blocked, A →T. All blocked, or P &  B blocked and A→T All ports open, restricted CENTER POSITION FUNCTION MATCHING P &  A blocked, B →T P & A blocked, B →T or all blocked P blocked, A →T and B →T P blocked, A →T or B →T P blocked, A →T and B →T restricted P blocked, A →T or B →T restricted P &  B blocked, A →T All blocked, or P &  B blocked and A →T All ports open, restricted VSD*M-VPD*M -...

Open the catalog to page 5
VSD*M-VPD*M - 6

PERFORMANCE CURVES FOR VSD05*M - VPD05*M VSD*M-VPD*M - PILOT OPERATED DIRECTIONAL VALVES FLOW GAIN FLOW CURVE NUMBER SPOOL NOTE: Curves obtained with mineral oil with viscosity of 170 SUS (36 cSt) at 122°F (50°C). RESPONSE TIME TIMES [ms] NOTE: The values indicated refer to a solenoid valve working with 1450 psi (100 bar) pilot pressure, with mineral oil at 120°F (50°C) and viscosity of 165 SUS (36cSt). The energizing and de-energizing times are obtained at the point pressure changes in the work ports. WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

Open the catalog to page 6
VSD*M-VPD*M - 7

PERFORMANCE CURVES FOR VSD07M - VPD07M FLOW GAIN VSD*M-VPD*M - PILOT OPERATED DIRECTIONAL VALVES FLOW CURVE NUMBER SPOOL NOTE: Curves obtained with mineral oil with viscosity of 170 SUS (36 cSt) at 122°F (50°C). RESPONSE TIME TIMES [ms] NOTE: The values indicated refer to a solenoid valve working with 1450 psi (100 bar) pilot pressure, with mineral oil at 120°F (50°C) and viscosity of 165 SUS (36cSt). The energizing and de-energizing times are obtained at the point pressure changes in the work ports. SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM

Open the catalog to page 7
VSD*M-VPD*M - 8

PERFORMANCE CURVES FOR VSD08M - VPD08M VSD*M-VPD*M - PILOT OPERATED DIRECTIONAL VALVES FLOW GAIN FLOW CURVE NUMBER SPOOL NOTE: Curves obtained with mineral oil with viscosity of 170 SUS (36 cSt) at 122°F (50°C). RESPONSE TIME TIMES [ms] NOTE: The values indicated refer to a solenoid valve working with 1450 psi (100 bar) pilot pressure, with mineral oil at 120°F (50°C) and viscosity of 165 SUS (36cSt). The energizing and de-energizing times are obtained at the point pressure changes in the work ports. WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

Open the catalog to page 8
VSD*M-VPD*M - 9

PERFORMANCE CURVES FOR VSD10M - VPD10M FLOW GAIN VSD*M-VPD*M - PILOT OPERATED DIRECTIONAL VALVES FLOW CURVE NUMBER SPOOL NOTE: Curves obtained with mineral oil with viscosity of 170 SUS (36 cSt) at 122°F (50°C) and pilot valve at 24V AC. RESPONSE TIME TIMES [ms] NOTE: The values indicated refer to a solenoid valve working with 1450 psi (100 bar) pilot pressure, with mineral oil at 120°F (50°C) and viscosity of 165 SUS (36cSt). The energizing and de-energizing times are obtained at the point pressure changes in the work ports. SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM

Open the catalog to page 9
VSD*M-VPD*M - 10

MECHANICAL OPTIONS VSD*M-VPD*M - PILOT OPERATED DIRECTIONAL VALVES STROKE ADJUSTMENT (JJ) This modification controls the flow of oil through the valve by limiting spool movement. It is used in hydraulic systems to govern the speed of system components. This solution allows control of the flow rate from the pump to the actuator and from the actuator to the outlet, obtaining a double adjustable control on the actuator. It is possible to order the valve with the stroke adj. on one side only. To request these options add the letters JA or JB in the Mechanical options box in the identification...

Open the catalog to page 10
VSD*M-VPD*M - 11

PILOT AND DRAIN CONFIGURATION The VPD*M valves are available with external pilot and drain only. The VSD*M valves are available with four pilot/drain configurations: internal/internal, internal/external, external/internal and external/external. It may be desirable to use external pilot when system pressure is subject to wide flucuations. It is required to use external pilot or internal pilot with a pressure reducing valve when system pressure exceeds 3000 psi (210 bar) for the VSD05*M, VSD07M and VSD10M. An external drain must be used when an open center (B) or a tandem center (L) spool is...

Open the catalog to page 11

All CONTINENTAL HYDRAULICS catalogs and technical brochures

  1. C03 MSV-P*

    4 Pages

  2. F0*MSV-BV

    6 Pages

  3. JIC Style

    76 Pages

  4. VED03M

    12 Pages

  5. VSD03M*-S

    12 Pages

  6. PVER

    10 Pages

  7. LPV series

    20 Pages

  8. VED*HL KD2

    30 Pages

  9. VED03MX

    10 Pages

  10. VSD*S

    34 Pages

  11. PVX

    52 Pages

  12. VSD03M

    12 Pages

  13. VS6M

    8 Pages

  14. VSNG6

    10 Pages

  15. VSD05M

    12 Pages

  16. VSNG10

    8 Pages

  17. VSD*HL-*-KD2

    28 Pages

  18. Power Unit

    146 Pages

Archived catalogs

  1. Power Units

    155 Pages