VED*HL KD2
1 /30Pages

VED*HL KD2

VED*HL KD2
1 /30Pages

Catalog excerpts

VED*HL KD2-1

VED*HL-*-KD2 HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES (IN COMPLIANCE WITH ATEX 94/4/EC) 5505 WEST 123RD STREET • SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES CONTINENTAL HYDRAULICS

 Open the catalog to page 1
VED*HL KD2-2

CONTINENTAL c: HYDRAULICS VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES TYPICAL PERFORMANCE SPECIFICATIONS WWW.CONTINENTALHYDRAULICS.COM - [email protected]

 Open the catalog to page 2
VED*HL KD2-3

VED03HL-D03 HAZARDOUS SIZE LOCATION Dual Solenoid 3 Position Spring Centered Single operator 2 Position Spring Centered KD2 VALVE ATEX APPROVAL For gases, vapors, mists: EX II 2G IIC T4 Gb For dust: EX II 2D IIIC T 154°C Db (protection type of the coil "d") MECHANICAL OPTIONS OMIT IF NOT REQUIRED - DESIGN LETTER SOLENOIDS see codes on page 20 TEMPERATURE CLASS NOMINAL FLOW (with Dp P-T 143 psi) TERMINAL BLOCK CONNECT TYPICAL ORDERING CODE: VED03HL-3AC-26-AT03-KD2-12D-A NOTE: The Zinc-Nickel body finishing surface treatment ensures a salt spray resistance up to 600 h (test operated according to...

 Open the catalog to page 3
VED*HL KD2-4

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES PERFORMANCE CURVES FOR AC SPOOL Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C); the Dp values are measured between P and T (full loop) valve ports. FLOW CHARACTERISTICS FLOW CHARACTERISTICS OPERATING LIMITS OPERATING LIMITS NOTES: Curves obtained with VED03HL 24V version. WWW.CONTINENTALHYDRAULICS.COM - [email protected]

 Open the catalog to page 4
VED*HL KD2-5

Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C); the Dp values are measured between P and T (full loop) valve ports. FLOW CHARACTERISTICS FLOW CHARACTERISTICS OPERATING LIMITS VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES PERFORMANCE CURVES FOR AC SPOOL OPERATING LIMITS NOTES: Curves obtained with VED03HL 24V version. [email protected] - WWW.CONTINENTALHYDRAULICS.COM

 Open the catalog to page 5
VED*HL KD2-6

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES PERFORMANCE CURVES FOR FC SPOOL Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C); the Dp values are measured between P and T (full loop) valve ports. FLOW CHARACTERISTICS FLOW CHARACTERISTICS OPERATING LIMITS OPERATING LIMITS NOTES: Curves obtained with VED03HL 24V version. WWW.CONTINENTALHYDRAULICS.COM - [email protected]

 Open the catalog to page 6
VED*HL KD2-7

CONTINENTAL ET HYDRAULICS PERFORMANCE CURVES FOR FC SPOOL Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C); the Dp values are measured between P and T (full loop) valve ports. FC-16 FC-26 VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES NOTES: Curves obtained with VED03HL 24V version. RESPONSE TIME [email protected] - WWW.CONTINENTALHYDRAULICS.COM

 Open the catalog to page 7
VED*HL KD2-8

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES OVERALL AND MOUNTING DIMENSIONS THREAD OF MOUNTING HOLE 10-24 UNC-2B - 0.50 FASTENING 4 bolts - 10-24 UNC-3A X 1 1/4 TIGHTENING TORQUE 4-5 lbf-ft (5.5-6.8 Nm) SEALING RINGS 4 O-rings AS568-012 90 Shore A VED03HL-3*-T* Manual override boot (STD) Cable gland to be ordered separately Coil Removal Space Mounting surface with sealing rings: 4 pcs. AS568-012 90 Shore A VED03HL-5*-S* Solenoid position for “R”Mechanical Option Side connection shape Cable gland to be ordered separately Mounting surface with sealing rings:4...

 Open the catalog to page 8
VED*HL KD2-9

IDENTIFICATION CODE - HAZARDOUS LOCATION - PILOT OPERATED VEDIHL- HAZARDOUS LOCATION DESIGN LETTER VALVE ATEX APPROVAL For gases, vapors, mists: EX II 2G IIC T4 Gb For dust: EX II 2D IIIC T 154°C Db (protection type of the coil "d") SOLENOIDS see codes on page 20 MECHANICAL OPTIONS OMIT IF NOT REQUIRED INTERNAL PILOT OPTIONS TEMPERATURE CLASS Dual Solenoid 3 Position Spring Centered Single operator 2 Position Spring Centered NOMINAL FLOW (with Dp P-T 145 psi) PILOT / DRAIN TERMINAL BLOCK CONNECT TYPICAL ORDERING CODE: VED07HL-3AC-150-A2T03-KD2-24D-A NOTE: The valve is supplied with STD surface...

 Open the catalog to page 9
VED*HL KD2-10

CONTINENTAL c: HYDRAULICS VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES PERFORMANCE CURVES - FLOW GAIN 1. Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C) and VED*HL at 24V with external amplifier. 2. The Dp values are measured between P and T (full loop) valve ports. 3. Typical flow rate curves at constant Dp related to the reference signal and measured for the available spools. VED05*HL VED07HL RESPONSE TIME RESPONSE TIME VED05*HL

 Open the catalog to page 10
VED*HL KD2-11

1. Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C) and VED*HL at 24V with external amplifier. 2. The Dp values are measured between P and T (full loop) valve ports. 3. Typical flow rate curves at constant Dp related to the reference signal and measured for the available spools. VED08HL VED10HL AC-200/FC-200 AC-350/FC-350 VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES RESPONSE TIME RESPONSE TIME VED08HL [email protected] - WWW.CONTINENTALHYDRAULICS.COM

 Open the catalog to page 11
VED*HL KD2-12

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES OVERALL AND MOUNTING DIMENSIONS FOR VED05*HL Dimensions in mm [IN] THREAD OF MOUNTING HOLE 1/4 - 20 UNC-2B x 0.60 FASTENING 4 bolts - 1/4 - 20 UNC-3A X 1 1/2 TIGHTENING TORQUE 6 lbf-ft (8 Nm) SEALING RINGS 5 O-rings AS568-014 90 Shore A 2 O-rings AS568-012 90 Shore A Manual override boot (STD) Coil Removal Space Cable gland to be ordered separately SOL. ‘B’ Mounting surface with sealing rings VED05*HL-5*-*S* Solenoid position for “R” Mechanical Option Cable gland to be ordered separately WWW.CONTINENTALHYDRAULICS.COM...

 Open the catalog to page 12
VED*HL KD2-13

Manual override boot (STD) Coil Removal Space Cable gland to be ordered separately SOL. ‘A’ VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES OVERALL AND MOUNTING DIMENSIONS FOR VED07HL Mounting surface with sealing rings VED07HL-5*-*S* Solenoid position for “R” Mechanical Option Side connection shape Cable gland to be ordered separately [email protected] - WWW.CONTINENTALHYDRAULIC

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.