VED*HL KD2
30Pages

{{requestButtons}}

Catalog excerpts

VED*HL KD2 - 1

VED*HL-*-KD2 HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES (IN COMPLIANCE WITH ATEX 94/4/EC) 5505 WEST 123RD STREET • SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES CONTINENTAL HYDRAULICS

Open the catalog to page 1
VED*HL KD2 - 2

CONTINENTAL c: HYDRAULICS VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES TYPICAL PERFORMANCE SPECIFICATIONS WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

Open the catalog to page 2
VED*HL KD2 - 3

VED03HL-D03 HAZARDOUS SIZE LOCATION Dual Solenoid 3 Position Spring Centered Single operator 2 Position Spring Centered KD2 VALVE ATEX APPROVAL For gases, vapors, mists: EX II 2G IIC T4 Gb For dust: EX II 2D IIIC T 154°C Db (protection type of the coil "d") MECHANICAL OPTIONS OMIT IF NOT REQUIRED - DESIGN LETTER SOLENOIDS see codes on page 20 TEMPERATURE CLASS NOMINAL FLOW (with Dp P-T 143 psi) TERMINAL BLOCK CONNECT TYPICAL ORDERING CODE: VED03HL-3AC-26-AT03-KD2-12D-A NOTE: The Zinc-Nickel body finishing surface treatment ensures a salt spray resistance up to 600 h (test operated according...

Open the catalog to page 3
VED*HL KD2 - 4

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES PERFORMANCE CURVES FOR AC SPOOL Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C); the Dp values are measured between P and T (full loop) valve ports. FLOW CHARACTERISTICS FLOW CHARACTERISTICS OPERATING LIMITS OPERATING LIMITS NOTES: Curves obtained with VED03HL 24V version. WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

Open the catalog to page 4
VED*HL KD2 - 5

Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C); the Dp values are measured between P and T (full loop) valve ports. FLOW CHARACTERISTICS FLOW CHARACTERISTICS OPERATING LIMITS VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES PERFORMANCE CURVES FOR AC SPOOL OPERATING LIMITS NOTES: Curves obtained with VED03HL 24V version. SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM

Open the catalog to page 5
VED*HL KD2 - 6

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES PERFORMANCE CURVES FOR FC SPOOL Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C); the Dp values are measured between P and T (full loop) valve ports. FLOW CHARACTERISTICS FLOW CHARACTERISTICS OPERATING LIMITS OPERATING LIMITS NOTES: Curves obtained with VED03HL 24V version. WWW.CONTINENTALHYDRAULICS.COM - SALES@CONTHYD.COM

Open the catalog to page 6
VED*HL KD2 - 7

CONTINENTAL ET HYDRAULICS PERFORMANCE CURVES FOR FC SPOOL Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C); the Dp values are measured between P and T (full loop) valve ports. FC-16 FC-26 VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES NOTES: Curves obtained with VED03HL 24V version. RESPONSE TIME SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM

Open the catalog to page 7
VED*HL KD2 - 8

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES OVERALL AND MOUNTING DIMENSIONS THREAD OF MOUNTING HOLE 10-24 UNC-2B - 0.50 FASTENING 4 bolts - 10-24 UNC-3A X 1 1/4 TIGHTENING TORQUE 4-5 lbf-ft (5.5-6.8 Nm) SEALING RINGS 4 O-rings AS568-012 90 Shore A VED03HL-3*-T* Manual override boot (STD) Cable gland to be ordered separately Coil Removal Space Mounting surface with sealing rings: 4 pcs. AS568-012 90 Shore A VED03HL-5*-S* Solenoid position for “R”Mechanical Option Side connection shape Cable gland to be ordered separately Mounting surface with sealing...

Open the catalog to page 8
VED*HL KD2 - 9

IDENTIFICATION CODE - HAZARDOUS LOCATION - PILOT OPERATED VEDIHL- HAZARDOUS LOCATION DESIGN LETTER VALVE ATEX APPROVAL For gases, vapors, mists: EX II 2G IIC T4 Gb For dust: EX II 2D IIIC T 154°C Db (protection type of the coil "d") SOLENOIDS see codes on page 20 MECHANICAL OPTIONS OMIT IF NOT REQUIRED INTERNAL PILOT OPTIONS TEMPERATURE CLASS Dual Solenoid 3 Position Spring Centered Single operator 2 Position Spring Centered NOMINAL FLOW (with Dp P-T 145 psi) PILOT / DRAIN TERMINAL BLOCK CONNECT TYPICAL ORDERING CODE: VED07HL-3AC-150-A2T03-KD2-24D-A NOTE: The valve is supplied with STD...

Open the catalog to page 9
VED*HL KD2 - 10

CONTINENTAL c: HYDRAULICS VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES PERFORMANCE CURVES - FLOW GAIN 1. Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C) and VED*HL at 24V with external amplifier. 2. The Dp values are measured between P and T (full loop) valve ports. 3. Typical flow rate curves at constant Dp related to the reference signal and measured for the available spools. VED05*HL VED07HL RESPONSE TIME RESPONSE TIME VED05*HL

Open the catalog to page 10
VED*HL KD2 - 11

1. Curves obtained with mineral oil viscosity of 170 sus (36 cSt) at 122°F (50°C) and VED*HL at 24V with external amplifier. 2. The Dp values are measured between P and T (full loop) valve ports. 3. Typical flow rate curves at constant Dp related to the reference signal and measured for the available spools. VED08HL VED10HL AC-200/FC-200 AC-350/FC-350 VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES RESPONSE TIME RESPONSE TIME VED08HL SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULICS.COM

Open the catalog to page 11
VED*HL KD2 - 12

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES OVERALL AND MOUNTING DIMENSIONS FOR VED05*HL Dimensions in mm [IN] THREAD OF MOUNTING HOLE 1/4 - 20 UNC-2B x 0.60 FASTENING 4 bolts - 1/4 - 20 UNC-3A X 1 1/2 TIGHTENING TORQUE 6 lbf-ft (8 Nm) SEALING RINGS 5 O-rings AS568-014 90 Shore A 2 O-rings AS568-012 90 Shore A Manual override boot (STD) Coil Removal Space Cable gland to be ordered separately SOL. ‘B’ Mounting surface with sealing rings VED05*HL-5*-*S* Solenoid position for “R” Mechanical Option Cable gland to be ordered separately...

Open the catalog to page 12
VED*HL KD2 - 13

Manual override boot (STD) Coil Removal Space Cable gland to be ordered separately SOL. ‘A’ VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES OVERALL AND MOUNTING DIMENSIONS FOR VED07HL Mounting surface with sealing rings VED07HL-5*-*S* Solenoid position for “R” Mechanical Option Side connection shape Cable gland to be ordered separately SALES@CONTHYD.COM - WWW.CONTINENTALHYDRAULIC

Open the catalog to page 13

All CONTINENTAL HYDRAULICS catalogs and technical brochures

  1. C03 MSV-P*

    4 Pages

  2. F0*MSV-BV

    6 Pages

  3. JIC Style

    76 Pages

  4. VED03M

    12 Pages

  5. VSD03M*-S

    12 Pages

  6. PVER

    10 Pages

  7. LPV series

    20 Pages

  8. VED03MX

    10 Pages

  9. VSD*S

    34 Pages

  10. PVX

    52 Pages

  11. VSD03M

    12 Pages

  12. VS6M

    8 Pages

  13. VSNG6

    10 Pages

  14. VSD05M

    12 Pages

  15. VSNG10

    8 Pages

  16. VSD*HL-*-KD2

    28 Pages

  17. VSD*M-VPD*M

    26 Pages

  18. Power Unit

    146 Pages

Archived catalogs

  1. Power Units

    155 Pages