Continental Double Disc Assembly
2Pages

{{requestButtons}}

Catalog excerpts

Continental Double Disc Assembly - 1

Continental Double Disc Assembly FEATURES: Double Safe No product loss from leakage Immediate shut down unnecessary Quick opening valve on command Lower pressure discs No moving parts Fail Safe Available in all standard materials, in all flange assemblies and ANSI ratings; standard, composite or reverse buckling discs. APPLICATION: Zero Leakage - A must with toxic contents or very valuable contents. Extremely corrosive conditions or damage could cause the process exposed rupture disc to leak. A pressure gauge in the midflange would indicate the leak, while a second rupture disc maintains the system leak free. The first rupture disc could then be changed out at an opportune time. Quick - Opening Device - By pressurizing the space between the two rupture discs in a Double Disc Assembly, one can obtain a quick opening device. Upon dumping the pressure between the two discs, full open area is obtained within a few milliseconds. The Double Disc Assembly, as a quick opening device, has been used in activating pressure systems, and to test systems for sudden pressure changes. Formulas on reverse side. Reaction Starter - The Double Disc Assembly has been used in applications such as testing liquid media which ignites on contact. In this situation, mixing two fuels prematurely could cause an unwanted explosion. By use of a Double Disc Assembly, the fuels could be contained separately until the Double Disc were activated to release the fuels into the system for ignition. PRICE - 1-3/4 times single disc assembly of same assembly, material and rating. DELIVERY - Same as standard assembly of same size and material. TECHNICAL DATA - See reverse side for how it works and design notes. 73-130

Open the catalog to page 1
Continental Double Disc Assembly - 2

CONTINENTAL DOUBLE DISC ASSEMBLY DOUBLE DISC ASSEMBLY TECHNICAL DATA D1 = outlet disc in psig D2 = inlet disc in psig P1 = pressure between in psig P2 = operating pressure in psig The operating pressure must be pre-determined. When application is Zero Leakage, P1 equals Zero. P1 = P2 - P1 = 70% for Standard disc D1 D2 P1 = P2 - P1 = 80% for CDC or CDCV composite disc D1 D2 P1 = P2 - P1 = 90% for reverse buckling disc D1 D2 Example: D2 = D1 P2 = 1000 psig P1 = P2 - P1 P1 = P2 = 1000 = 500 psig 2 2 2 P1 = P2 P1 P1 = P2 2 D1 = 80% D1 = 500 .80 = 625 psig D1 = D2 = 625 psig both discs Design...

Open the catalog to page 2

All Continental Disc Corp. catalogs and technical brochures

  1. B.D.I.®

    8 Pages

  2. BDI-FLX ™

    8 Pages

  3. CERTIFLOW®

    4 Pages

  4. BDI-FLX

    8 Pages

  5. HPX

    24 Pages

  6. Standard Type

    10 Pages

  7. V R D

    8 Pages

  8. Union Holder

    2 Pages

  9. CERTIFLOW ®

    4 Pages

Archived catalogs

  1. VENT PANELS

    12 Pages